SearcharxivSearch

arXiv subjects

E. L. Foley

Publications and source records attributed to E. L. Foley.

6 recordsLinked to original sources

Frequency-dependent amplitude correction to free-precession scalar magnetometers

Pump and probe scalar atomic magnetometers show incredible potential for real-world, traditionally difficult measurement environments due to their high dynamic range and linearity. Previously, it has been assumed these scalar magnetometer have a flat response across their bandwidth, and flat noise floor. Here we show that standard fitting routines, used to extract the magnetic field, result in a non-linear frequency dependent response across the sensor bandwidth, due to the time-averaged nature of such free precession measurements. We present an analytic correction dependent on dead-time, and show how this equation can also correct the sensor spectral density. The maximum in-band amplitude loss approaches 29\% as the frequency of interest becomes the Nyquist frequency, making a significant correction for applications such as source localization in magnetoencephalography. These pump and probe atomic magnetometers also are known to have large aliasing of out-of-band signals, and we propose a scheme where the frequency of out-of-band signals can be identified by performing fits with varying dead-time on the raw free-precession sensor data.

physics.atom-ph

Long spin-1/2 noble gas coherence times in mm-sized anodically bonded batch-fabricated $^{3}$He-$^{129}$Xe-$^{87}$Rb cells

As the only stable spin-1/2 noble gas isotopes, $^{3}$He and $^{129}$Xe are promising systems for inertial rotation sensing and searches for exotic spin couplings. Spin-1/2 noble gases have intrinsic coherence times on the order of hours to days, which allows for incredibly low frequency error of free-precession measurements. However relaxation in miniature cells is dominated by interactions with the cell wall, which limits the performance of a chip-scale sensor that uses noble gases. While $^{129}$Xe wall relaxation times have previously been limited to 10's of seconds in mm-sized cells, we demonstrate the first anodically bonded batch-fabricated cells with dual $^{3}$He-$^{129}$Xe isotopes and $^{87}$Rb in a 6~mm$^3$ volume with $^{3}$He and $^{129}$Xe $T_2$ coherence times of, respectively, 4 h and 300 s. We use these microfabricated cells in a dual noble-gas comagnetometer and discuss its limits.

physics.atom-ph

Femtotesla nearly quantum-noise-limited pulsed gradiometer at Earth-scale fields

We describe a finite fields magnetic gradiometer using an intense pulsed laser to polarize a $^{87}$Rb atomic ensemble and a compact VCSEL probe laser to detect paramagnetic Faraday rotation in a single multipass cell. We report differential magnetic sensitivity of $14$ fT/Hz$^{1/2}$ over a broad dynamic range including Earth's field magnitude and common-mode rejection ratio higher than $10^4$. We also observe a nearly quantum-noise-limited behaviour of the gradiometer, by comparing the experimental standard deviation of the estimated frequency difference against the Cramér-Rao lower bound in the presence of white photon shot-noise, atomic spin noise and atomic diffusion.

physics.atom-ph

Heading errors in all-optical alkali-vapor magnetometers in geomagnetic fields

Alkali-metal atomic magnetometers suffer from heading errors in geomagnetic fields as the measured magnetic field depends on the orientation of the sensor with respect to the field. In addition to the nonlinear Zeeman splitting, the difference between Zeeman resonances in the two hyperfine ground states can also generate heading errors depending on initial spin polarization. We examine heading errors in an all-optical scalar magnetometer that uses free precession of polarized $^{87}\text{Rb}$ atoms by varying the direction and magnitude of the magnetic field at different spin polarization regimes. In the high polarization limit where the lower hyperfine ground state $F = 1$ is almost depopulated, we show that heading errors can be corrected with an analytical expression, reducing the errors by two orders of magnitude in Earth's field. We also verify the linearity of the measured Zeeman precession frequency with the magnetic field. With lower spin polarization, we find that the splitting of the Zeeman resonances for the two hyperfine states causes beating in the precession signals and nonlinearity of the measured precession frequency with the magnetic field. We correct for the frequency shifts by using the unique probe geometry where two orthogonal probe beams measure opposite relative phases between the two hyperfine states during the spin precession.

physics.atom-ph

Portable magnetometry for detection of biomagnetism in ambient environments

We present a method of optical magnetometry with parts-per-billion resolution that is able to detect biomagnetic signals generated from the human brain and heart in Earth's ambient environment. Our magnetically silent sensors measure the total magnetic field by detecting the free-precession frequency of highly spin-polarized alkali metal vapor. A first-order gradiometer is formed from two magnetometers that are separated by a 3 cm baseline. Our gradiometer operates from a laptop consuming 5 W over a USB port, enabled by state-of-the-art micro-fabricated alkali vapor cells, advanced thermal insulation, custom electronics, and laser packages within the sensor head. The gradiometer obtains a sensitivity of 16 fT/cm/Hz$^{1/2}$ outdoors, which we use to detect neuronal electrical currents and magnetic cardiography signals. Recording of neuronal magnetic fields is one of a few available methods for non-invasive functional brain imaging that usually requires extensive magnetic shielding and other infractructure. This work demonstrates the possibility of a dense array of portable biomagnetic sensors that are deployable in a variety of natural environments.

physics.med-ph

Dipolar and scalar $^3$He and $^{129}$Xe frequency shifts in mm-sized cells

We describe a $^{3}$He-$^{129}$Xe comagnetometer operating in stemless anodically bonded cells with a 6 mm$^3$ volume and a $^{129}$Xe spin coherence time of 300 sec. We use a $^{87}$Rb pulse-train magnetometer with co-linear pump and probe beams to study the nuclear spin frequency shifts caused by spin polarization of $^{3}$He. By systematically varying the cell geometry in a batch cell fabrication process we can separately measure the cell shape dependent and independent frequency shifts. We find that a certain aspect ratio of the cylindrical cell can cancel the effects of $^3$He magnetization that limit the stability of vapor-cell comagnetometers. Using this control we also observe for the first time a scalar $^{3}$He-$^{129}$Xe collisional frequency shift characterized by an enhancement factor $κ_{\text{HeXe}} = -0.011\pm0.001$.

physics.atom-ph