Searcharxiv⌕ Search

arXiv subjects

E. Miller

Publications and source records attributed to E. Miller.

23 records · Page 2Linked to original sources

Simulating Astro-H Observations of Sloshing Gas Motions in the Cores of Galaxy Clusters

Astro-H will be the first X-ray observatory to employ a high-resolution microcalorimeter, capable of measuring the shift and width of individual spectral lines to the precision necessary for estimating the velocity of the diffuse plasma in galaxy clusters. This new capability is expected to bring significant progress in understanding the dynamics, and therefore the physics, of the intracluster medium. However, because this plasma is optically thin, projection effects will be an important complicating factor in interpreting future Astro-H measurements. To study these effects in detail, we performed an analysis of the velocity field from simulations of a galaxy cluster experiencing gas sloshing, and generated synthetic X-ray spectra, convolved with model Astro-H Soft X-ray Spectrometer (SXS) responses. We find that the sloshing motions produce velocity signatures that will be observable by Astro-H in nearby clusters: the shifting of the line centroid produced by the fast-moving cold gas underneath the front surface, and line broadening produced by the smooth variation of this motion along the line of sight. The line shapes arising from inviscid or strongly viscous simulations are very similar, indicating that placing constraints on the gas viscosity from these measurements will be difficult. Our spectroscopic analysis demonstrates that, for adequate exposures, Astro-H will be able to recover the first two moments of the velocity distribution of these motions accurately, and in some cases multiple velocity components may be discerned. The simulations also confirm the importance of accurate treatment of PSF scattering in the interpretation of Astro-H/SXS spectra of cluster plasmas.

astro-ph.HE↗

ASTRO-H White Paper - New Spectral Features

This white paper addresses selected new (to X-ray astronomy) physics and data analysis issues that will impact ASTRO-H SWG observations as a result of its high-spectral-resolution X-ray microcalorimeter, the focussing hard X-ray optics and corresponding detectors, and the low background soft gamma-ray detector. We concentrate on issues of atomic and nuclear physics, including basic bound-bound and bound-free transitions as well as scattering and radiative transfer. The major topic categories include the physics of charge exchange, solar system X-ray sources, advanced spectral model, radiative transfer, and hard X-ray emission lines and sources.

astro-ph.HE↗

ASTRO-H White Paper - Clusters of Galaxies and Related Science

The next generation X-ray observatory ASTRO-H will open up a new dimension in the study of galaxy clusters by achieving for the first time the spectral resolution required to measure velocities of the intracluster plasma, and extending at the same time the spectral coverage to energies well beyond 10 keV. This white paper provides an overview of the capabilities of ASTRO-H for exploring gas motions in galaxy clusters including their cosmological implications, the physics of AGN feedback, dynamics of cluster mergers as well as associated high-energy processes, chemical enrichment of the intracluster medium, and the nature of missing baryons and unidentified dark matter.

astro-ph.HE↗

Spin-Dependent Limits from the DRIFT-IId Directional Dark Matter Detector

Data are presented from the DRIFT-IId detector housed in the Boulby mine in northeast England. A 0.8 m^3 fiducial volume, containing partial pressures of 30 Torr CS2 and 10 Torr CF4, was exposed for a duration of 47.4 live-time days with sufficient passive shielding to provide a neutron free environment within the detector. The nuclear recoil events seen are consistent with a remaining low level background from the decay of progeny of radon daughters attached to the central cathode of the detector. However, energy depositions from such events must drift across the entire width of the detector, and thus display large diffusion upon reaching the readout planes of the device. Exploiting this feature, it is shown to be possible to reject energy depositions from these radon decay progeny events while still retaining sensitivity to nuclear recoil events. The response of the detector is then interpreted, using the F nuclei content of the gas, in terms of sensitivity to proton spin-dependent WIMP-nucleon interactions, displaying a minimum in sensitivity cross section at 0.5 pb for a WIMP mass of 100 GeV/c^2.

astro-ph.CO↗

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO↗