SearcharxivSearch

arXiv subjects

E. Neufeld

Publications and source records attributed to E. Neufeld.

2 recordsLinked to original sources

A Gaussian process based approach for validation of multi-variable measurement systems: application to SAR measurement systems

Resource-efficient and robust validation of systems designed to measure a multi-dimensional parameter space is an unsolved problem as it would require millions of test permutations for comprehensive validation coverage. In the paper, an efficient and comprehensive validation approach based on a Gaussian Process (GP) model of the test system has been developed that can operate system-agnostically, avoids calibration to a fixed set of known validation benchmarks, and supports large configuration spaces. The approach consists of three steps that can be performed independently by different parties: 1) GP model creation, 2) model confirmation, and 3) targeted search for critical cases. It has been applied to two systems that measure specific absorption rate (SAR) for compliance testing of wireless devices and apply different SAR measurement methods: a probe-scanning system (per IEC/IEEE 62209-1528), and a static sensor-array system (per IEC 62209-3). The results demonstrate that the approach is practical, feasible, suitable for proving effective equivalence, and can be applied to any measurement method and implementation. The presented method is sufficiently general to be of value not only for SAR system validation, but also in a wide variety of applications that require critical, independent, and efficient validation.

stat.AP

Towards Blood Flow in the Virtual Human: Efficient Self-Coupling of HemeLB

Many scientific and medical researchers are working towards the creation of a virtual human - a personalised digital copy of an individual - that will assist in a patient's diagnosis, treatment and recovery. The complex nature of living systems means that the development of this remains a major challenge. We describe progress in enabling the HemeLB lattice Boltzmann code to simulate 3D macroscopic blood flow on a full human scale. Significant developments in memory management and load balancing allow near linear scaling performance of the code on hundreds of thousands of computer cores. Integral to the construction of a virtual human, we also outline the implementation of a self-coupling strategy for HemeLB. This allows simultaneous simulation of arterial and venous vascular trees based on human-specific geometries.

physics.med-ph