SearcharxivSearch

arXiv subjects

E. Panontin

Publications and source records attributed to E. Panontin.

2 recordsLinked to original sources

Synthetic model of gamma-ray emission during DT experiments on the SPARC tokamak

In thermonuclear plasmas, plasma ions undergoing nuclear reactions emit gamma-rays with energies in the MeV range. Their spectroscopy can convey much plasma information, such as the DT fusion power, the spatial and velocity distributions of the fast ions, and the plasma heating performance. In the present work, we simulate the gamma-ray emission expected in the SPARC tokamak during a primary reference discharge, when the tokamak is expected to generate $140$ MW of fusion power and reach an energy gain factor of $Q\approx11$. We focus particularly T(D, $γ$)He-5, B-10(He-4, p $γ$)C-13 and D(He-3, $γ$)Li-5 reactions. We use realistic plasma profiles calculated with the TRANSP code and simulate radiofrequency heating of the plasma with CQL3D and TORIC. Possible locations for gamma spectrometers based on lanthanum bromide inorganic scintillators are suggested. For each, the signal-to-noise ratio of gamma-rays over neutrons is evaluated using the ray-tracing code ToFu and high fidelity Monte Carlo models (MCNP and OpenMC) to solve radiation transport in SPARC. A dedicated neutron attenuator made of high density polyethylene is scoped to allow gamma-spectroscopy during high neutron yield experiments. And finally, the performance of LaBr$_3$ detectors in reconstructing the fusion power generated by SPARC is discussed.

physics.plasm-ph

Effects of 3D printed capsule material on activation thin foil irradiation and counting for fusion neutron yield measurements

Activation foils are used to independently measure the time integrated neutron yield and total fusion energy produced in both inertial and magnetic confinement fusion, making them crucial in the neutron diagnostic suite. The activated foils must be remotely transported from the neutron source to the detector inside of a small capsule, which can impact both the foil irradiation and the associated activation measurement. The aim of this paper is to evaluate the performance of various activation foils and to characterize the effects of different capsule materials to inform the design choices for future systems, such as the SPARC tokamak. Through a combination of FISPACT simulations and irradiation experiments with a deuterium-tritium neutron generator, we tested several different material choices for foils, capsules, and gamma-ray spectrometers. Aluminum and copper foils are found to be suitable for a multi-foil irradiation configuration. The use of 3D-printed thermoplastic capsules reduces the number of measured decay-photon counts, yet the reduction is smaller than the associated measurement uncertainty. Finally, lanthanum-based detectors are shown to be viable alternatives to the standard high-purity germanium spectrometer, although with poorer energy resolution.

physics.ins-det