SearcharxivSearch

arXiv subjects

E. Paoloni

Publications and source records attributed to E. Paoloni.

At least 19 recordsLinked to original sources

Search for two-neutrino double electron capture in $^{36}$Ar with the DarkSide-50 detector

Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shells and two neutrinos are emitted. We report on the first search for two-neutrino double electron capture in the $\textit{KK}$- and $\textit{KL}$-shells of $^{36}$Ar using the low-radioactivity liquid argon target from underground sources in the DarkSide-50 experiment. No statistically significant excess was observed with approximately 12 ton-day exposure of underground argon (UAr) and, taking into account the $^{36}$Ar isotopic abundance in UAr (0.007%), we set a limit on the half-life of the two-electron capture process in $^{36}$Ar of $T_{1/2} > 9.2 \times 10^{19}$ yr at 90% C.L. The sensitivity of the DarkSide-20k experiment, which will become operational in the next few years, was also evaluated and is expected to increase by a factor $\sim$100 with 10 years of expected operation and assuming the same $^{36}$Ar abundance as in the DarkSide-50 underground argon target.

nucl-ex

First Nuclear Ultra-Heavy Dark Matter Search in Argon Time Projection Chambers with the DarkSide-50 Experiment

We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of $m_\chi = 10, 50, 100, 500 \, \mathrm{GeV/c^2}$ are presented.

hep-ex

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

hep-ex

Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50

We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.

hep-ph

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

physics.ins-det

Search for dark matter annual modulation with DarkSide-50

Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.

hep-ex

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

hep-ex

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

Search for low mass dark matter in DarkSide-50: the bayesian network approach

We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

hep-ex

Search for low-mass dark matter WIMPs with 12 ton-day exposure of DarkSide-50

We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keV$_{er}$. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV/c$^2$ mass WIMP on nucleons is set at 6$\times$10$^{-43}$ cm$^2$, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the $[1.2, 3.6]$ GeV/c$^2$ WIMP mass range.

hep-ex

Search for dark matter-nucleon interactions via Migdal effect with DarkSide-50

Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12306 $\pm$ 184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c$^2$. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below $3.6$ GeV/c$^2$.

hep-ex

Search for dark matter particle interactions with electron final states with DarkSide-50

We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark photon kinetic mixing parameter $κ$. We also set the first dark matter direct-detection constraints on the mixing angle $\left|U_{e4}\right|^2$ for keV sterile neutrinos.

hep-ex

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

The Silicon Vertex Detector of the Belle II Experiment

In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.

physics.ins-det

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all kind of observed events, is essential for an optimal design of the new experiment. In this paper, we report on a particular set of events, which were not used for dark matter searches. Namely, standard two-pulse scintillation-ionization signals accompanied by a small amplitude third pulse, originating from single or few electrons, in a time window of less than a maximum drift time. We compare our findings to those of a recent paper of the LUX Collaboration (D.S.Akerib et al. Phys.Rev.D 102, 092004). Indeed, both experiments observe events related to photoionization of the cathode. From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths around 128 nm, in liquid argon. Also, both experiments observe events likely related to photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be one order of magnitude smaller in DarkSide-50 than in LUX. This result, together with the much larger measured electron lifetime, coherently hints toward a lower concentration of contaminants in DarkSide-50 than in LUX.

physics.ins-det

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to $\sim$180~eV$_{er}$, exploiting $^{37}$Ar and $^{39}$Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to $\sim$500~eV$_{nr}$, the lowest ever achieved in liquid argon, using \textit{in situ} neutron calibration sources and external datasets from neutron beam experiments.

physics.ins-det

Directional dark matter detection sensitivity of a two-phase liquid argon detector

We examine the sensitivity of a large scale two-phase liquid argon detector to the directionality of the dark matter signal. This study was performed under the assumption that, above 50 keV of recoil energy, one can determine (with some resolution) the direction of the recoil nucleus without head-tail discrimination, as suggested by past studies that proposed to exploit the dependence of columnar recombination on the angle between the recoil nucleus direction and the electric field. In this paper we study the differential interaction recoil rate as a function of the recoil direction angle with respect to the zenith for a detector located at the Laboratori Nazionali del Gran Sasso and we determine its diurnal and seasonal modulation. Using a likelihood-ratio based approach we show that, with the angular information alone, 100 events are enough to reject the isotropic hypothesis at three standard deviation level. For an exposure of 100 tonne years this would correspond to a spin independent WIMP-nucleon cross section of about 10^-46 cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong motivation for the experimental determination of directional recoil effects in two-phase liquid argon detectors.

astro-ph.CO

Demonstrator of the Belle II Online Tracking and Pixel Data Reduction on the High Level Trigger System

The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, a DEPFET-technology based silicon detector with pixel readout. A large fraction of the background hits can be rejected by defining a set of Regions Of Interest (ROI) on the pixel detector sensors and then recording just the data from the pixels inside the ROI. The ROIs are defined on an event by event basis by extrapolating back onto the PXD the charged tracks detected in the outer trackers (a 4 layer double-sided silicon strip detector surrounded by a wire chamber). The tracks are reconstructed in real time on the High Level Trigger (HLT). The pixel detector is then read out based on the ROI information. A demonstrator of this architecture was under beam test earlier this year in DESY (Hamburg, Germany). The demonstrator was operated in an electron beam whose momentum was in the 2-6 GeV/c range with a typical trigger rate of a few kHz in a magnetic field of strength up to 1 T. The demonstrator consists of one pixel sensor and 4 silicon strip sensors arranged in a 5 layers configuration mimicking the Belle II vertex detector. The detector readout was a scaled down version of the full Belle II DAQ + HLT chain. The demonstrator was used to detect the particles, reconstruct in real time the trajectories, identify the ROIs on the PXD plane and record the PXD data within. We describe the requirements and the architecture of the final system together with the results obtained with the demonstrator.

physics.ins-det