Radiation tolerance tests on key components of the ePIC-dRICH readout card

The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5x5x12 cm^3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.

physics.ins-det

Electron identification and hadron discrimination using Cherenkov radiation in air and SiPMs

This paper presents a method to identify electrons using the Cherenkov light emitted when a charged particle travels in air and photons are detected with a Silicon PhotoMultiplier (SiPM). The analysis is based on a photon-counting approach using SPAD cells and uses data collected during a test beam at CERN PS. The results are well described by a simple Monte Carlo simulation, which further demonstrates that a very good electron identification and a strong pion/hadron rejection could be obtained over a wide momentum range.

hep-ex

Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active area of around 3x3 mm$^\text{2}$ and a single-cell area of 40 $\mu$m$^\text{2}$. In addition, the SiPM performance after irradiation, in terms of timing response and dark count rate, has been evaluated for sensors with a 1x1 mm$^\text{2}$ area, demonstrating that SiPMs can maintain excellent timing capabilities and a low dark count rate when an appropriate threshold is applied to the signal.