Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC

The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.

physics.ins-det

Physics case for an LHCb Upgrade II - Opportunities in flavour physics, and beyond, in the HL-LHC era

The LHCb Upgrade II will fully exploit the flavour-physics opportunities of the HL-LHC, and study additional physics topics that take advantage of the forward acceptance of the LHCb spectrometer. The LHCb Upgrade I will begin operation in 2020. Consolidation will occur, and modest enhancements of the Upgrade I detector will be installed, in Long Shutdown 3 of the LHC (2025) and these are discussed here. The main Upgrade II detector will be installed in long shutdown 4 of the LHC (2030) and will build on the strengths of the current LHCb experiment and the Upgrade I. It will operate at a luminosity up to $ 2 \times 10^{34} \rm cm^{-2}s^{-1}$, ten times that of the Upgrade I detector. New detector components will improve the intrinsic performance of the experiment in certain key areas. An Expression Of Interest proposing Upgrade II was submitted in February 2017. The physics case for the Upgrade II is presented here in more depth. $CP$-violating phases will be measured with precisions unattainable at any other envisaged facility. The experiment will probe $b\to s \ell^+\ell^-$ and $b\to d \ell^+\ell^-$ transitions in both muon and electron decays in modes not accessible at Upgrade I. Minimal flavour violation will be tested with a precision measurement of the ratio of $B(B^0\toμ^+μ^-)/B(B_s^0\to μ^+μ^-)$. Probing charm $CP$ violation at the $10^{-5}$ level may result in its long sought discovery. Major advances in hadron spectroscopy will be possible, which will be powerful probes of low energy QCD. Upgrade II potentially will have the highest sensitivity of all the LHC experiments on the Higgs to charm-quark couplings. Generically, the new physics mass scale probed, for fixed couplings, will almost double compared with the pre-HL-LHC era; this extended reach for flavour physics is similar to that which would be achieved by the HE-LHC proposal for the energy frontier.

hep-ex

Experimental study of a liquid Xenon PET prototype module

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any parallax effect. This work reports on the performances of the first LXe prototype module, equipped with a position sensitive PMT operating in the VUV range (178 nm).

physics.med-ph

Variable placement of templates technique in a 2D parameter space for binary inspiral searches

In the search for binary systems inspiral signal in interferometric gravitational waves detectors, one needs the generation and placement of a grid of templates. We present an original technique for the placement in the associated parameter space, that makes use of the variation of size of the isomatch ellipses in order to reduce the number of templates necessary to cover the parameter space. This technique avoids the potentially expensive computation of the metric at every point, at the cost of having a small number of ``holes'' in the coverage, representing a few percent of the surface of the parameter space, where the match is slightly lower than specified. A study of the covering efficiency, as well as a comparison with a very simple regular tiling using a single ellipse is made. Simulations show an improvement varying between 6% and 30% for the computing cost in this comparison.

gr-qc

GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography

GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented : the design optimization of a liquid Xe micro-PET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 micro-PET camera.

physics.med-ph

The QCD/SM Working Group: Summary Report

This Report documents the results obtained by the Working Group on Quantum ChromoDynamics and the Standard Model for the Workshop ``Physics at TeV Colliders'', Les Houches, France, 21 May - 1 June 2001. The account of uncertainties in Parton Distribution Functions is reviewed. Progresses in the description of multiparton final states at Next-to-Leading Order and the extension of calculations for precision QCD observables beyond this order are summarized. Various issues concerning the relevance of resummation for observables at TeV colliders is examined. Improvements to algorithms of jet reconstruction are discussed and predictions for diphoton and photon pi-zero production at the LHC are made for kinematic variables of interest regarding searches for a Higgs boson decaying into two photons. Finally, several improvements implemented in Monte-Carlo event generators are documented.

hep-ph

Electroweak Results from LEP and SLC and Tests of the Standard Model

An update of the electroweak measurements at LEP and SLC is presented. These measurements are used to perform precise tests of the Standard Model. A constraint on the Standard Model Higgs mass is obtained when the direct measurements of $m_{top}$ and $M_W$ are included in the fit. A combination with the direct Higgs search is also shown.

hep-ex

Initial-Final-State Interference in the Z line-shape

The uncertainty in the determination of the Z line-shape parameters coming from the precision of the calculation of the Initial-State Radiation and Initial--Final-State Interference is 2 10**(-4) for the total cross section sigma zero(had) at the Z peak, 0.15 MeV for the Z mass M Z, and 0.1 MeV for the Z width Gamma Z. Corrections to Initial--Final-State Interference beyond \Order{α^1} are discussed.

hep-ph