SearcharxivSearch

arXiv subjects

E. Traykov

Publications and source records attributed to E. Traykov.

18 recordsLinked to original sources

Calibration of a $\Delta$E-E telescope based on CeBr$_3$ scintillator for secondary charged particles measurements in hadron therapy

Hadrontherapy is an established cancer treatment method that enables a more localized dose deposition compared to conventional radiotherapy, potentially reducing the dose to surrounding healthy tissues in certain clinical cases. However, a key limitation in current treatment planning lies in the limited experimental data available for the characterization of secondary particles generated by nuclear interactions of the primary beam with tissues, which directly impacts the accuracy of Monte Carlo tools and analytical models used in dose calculations. Indeed, this leads to the adoption of larger safety margins and can limit the use of hadrontherapy for treating certain complex or sensitive tumor locations. This work is part of the context of the characterization of secondary charged particles generated by ion beams in the energy range relevant for particle therapy applications, using a $\Delta E-E$ telescope comprising a CeBr$_3$ crystal scintillator and a plastic scintillator. The calibration and response of this telescope to ions commonly used in clinical settings is presented in this work, highlighting adherence to Birks' law for accurate energy measurements. This study is the first to optimize a $\Delta E-E$ telescope combining CeBr$_3$ and plastic scintillators specifically for secondary particle detection in hadrontherapy. It represents an essential step toward the experimental acquisition of nuclear data, enabling accurate measurement and identification of secondary charged particles generated by therapeutic beams in tissue-equivalent materials. The system is designed for use in controlled experimental setups that reproduce clinical conditions, with the goal of improving the predictive accuracy of treatment planning software through enhanced Monte Carlo simulation inputs.

physics.ins-det

LEEx-B: Low Energy Experimental Bench Development at IPHC-CNRS Strasbourg

As a part of future developments of beam diagnostics, a low energy experimental bench (LEEx-B) has been recently designed, built and commissioned at IPHC-CNRS of Strasbourg. The bench is composed of a Cs+ ion gun installed on a HV platform and providing beams up to 25 keV. A beam profiler and an Allison-type emittance-meter allow the qualification of the setup and also the characterization of the beam. During the commissioning process, the electronics, and the control system were upgraded in order to push the limits towards low beam currents measured by the emittance-meter.

physics.acc-ph

Green beam lines, a challenging concept

Due to increasing environmental and economic constraints, optimization of ion beam transport and equipment design becomes essential. The future should be equipped with planet-friendly facilities, that is, solutions that reduce environmental impact and improve economic competitiveness. The tendency to increase the intensity of the current and the power of the beams obliges us and brings us to new challenges. Installations tend to have larger dimensions with increased areas, volumes, weights and costs. A new ion beam transport prototype was developed and used as a test bed to identify key issues to reduce beam losses and preserve transverse phase-space distributions with large acceptance conditions.

physics.acc-ph

Design and Commissioning of the first two CYRC\'e Extension Beamlines

CYRC\'e is a TR24 cyclotron installed at the Institut Pluridisciplinaire Hubert Curien (IPHC) of Strasbourg operating at energies of 16-25 MeV and at intensities up to 400 $\mu$A. The accelerator is used to produce and provide radioelements for PET and for SPECT. In 2015, IPHC started to develop a platform with the aim of performing radiobiological experiments. The PRECy platform foresees to contain three-to-five experimental stations linked to beamlines expanded from the second exit port of the cyclotron. This extension allows devoting one of the beamlines for detector studies within the framework of the CMS project. The design, the development and the commissioning of the first two beamlines are discussed in this paper.

physics.acc-ph

New exotic beams from the SPIRAL 1 upgrade

Since 2001, the SPIRAL 1 facility has been one of the pioneering facilities in ISOL techniques for reaccelerating radioactive ion beams: the fragmentation of the heavy ion beams of GANIL on graphite targets and subsequent ionization in the Nanogan ECR ion source has permitted to deliver beams of gaseous elements (He, N, O, F, Ne, Ar, Kr) to numerous experiments. Thanks to the CIME cyclotron, energies up to 20 AMeV could be obtained. In 2014, the facility was stopped to undertake a major upgrade, with the aim to extend the production capabilities of SPIRAL 1 to a number of new elements. This upgrade, which is presently under commissioning, consists in the integration of an ECR booster in the SPIRAL 1 beam line to charge breed the beam of different 1+ sources. A FEBIAD source (the so-called VADIS from ISOLDE) was chosen to be the future workhorse for producing many metallic ion beams. The charge breeder is an upgraded version of the Phoenix booster which was previously tested in ISOLDE. The performances of the aforementioned ingredients of the upgrade (targets, 1+ source and charge breeder) have been and are still being optimized in the frame of different European projects (EMILIE, ENSAR and ENSAR2). The upgraded SPIRAL 1 facility will provide soon its first new beams for physics and further beam development are undertaken to prepare for the next AGATA campaign. The results obtained during the on-line commissioning period permit to evaluate intensities for new beams from the upgraded facility.

physics.acc-ph

Measurement of the half-life of the T=$\frac{1}{2}$ mirror decay of $^{19}$Ne and its implication on physics beyond the standard model

The $\frac{1}{2}^+ \rightarrow \frac{1}{2}^+$ superallowed mixed mirror decay of $^{19}$Ne to $^{19}$F is excellently suited for high precision studies of the weak interaction. However, there is some disagreement on the value of the half-life. In a new measurement we have determined this quantity to be $T_{1/2}$ = $17.2832 \pm 0.0051_{(stat)}$ $\pm 0.0066_{(sys)}$ s, which differs from the previous world average by 3 standard deviations. The impact of this measurement on limits for physics beyond the standard model such as the presence of tensor currents is discussed.

nucl-ex

Hyperfine Field and Hyperfine Anomalies of Copper Impurities in Iron

A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but is an order of magnitude more precise. It is consistent with predictions from ab initio calculations. Comparing the hyperfine field values obtained for the individual isotopes, the hyperfine anomalies in Fe were determined to be 59Δ69=0.15(9)% and 71Δ69=0.07(11)%.

nucl-ex

The half-life of $^{221}$Fr in Si and Au at 4K and at mK temperatures

The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the most precise value available in literature.

nucl-ex

Precision measurements of the $^{60}$Co $β$-asymmetry parameter in search for tensor currents in weak interactions

The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PIN diode operating at a temperature of about 10 K in a magnetic field of 0.6 T. Extensive GEANT4 Monte-Carlo simulations were performed to gain control over the systematic effects. Our result, $\widetilde{A} = -1.014(12)_{stat}(16)_{syst}$, is in agreement with the Standard-Model value of $-0.987(9)$, which includes recoil-order corrections that were addressed for the first time for this isotope. Further, it enables limits to be placed on possible tensor-type charged weak currents as well as other physics beyond the Standard Model.

nucl-ex

The beta-gamma decay of 21Na

A new and independent determination of the Gamow-Teller branching ratio in the beta-decay of 21Na is reported. The value obtained of 5.13 +- 0.43 % is in agreement with the currently adopted value and the most recent measurement. In contrast to previous experiments, the present method was based on the counting of the parent 21Na ions and the resulting 351 keV gamma-rays without coincident beta-particle detection.

nucl-ex

Beta asymmetry parameter in the decay of 114In

The beta asymmetry parameter A for the pure Gamow-Teller decay of 114In is reported. The low temperature nuclear orientation method was combined with a GEANT4 based simulation code allowing for the first time to address in detail the effects of scattering and of the magnetic field. The result, A = -0.994 +/- 0.010stat +/- 0.010syst, constitutes the most accurate value for the asymmetry parameter of a nuclear beta transition to date. The value is in agreement with the Standard Model prediction of A = -1 and provides new limits on tensor type charged weak currents.

nucl-ex

A GEANT4 Monte-Carlo Simulation Code for precision beta spectroscopy

The measurement of the beta asymmetry parameter in nuclear beta decay is a potentially very sensitive tool to search for non V-A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects that modify the emission pattern of the beta radiation, i.e. the geometry of the setup, the effect of the magnetic field on the trajectories of beta particles as well as (back)scattering in the source, on the sample holder and on the detector, have to be correctly taken into account in the analysis of the data. A thorough study of these effects and a new method based on detailed GEANT4 Monte-Carlo simulations that was developed for this purpose is presented here. The code was developed for beta asymmetry measurements by means of the Low Temperature Nuclear Orientation (LTNO) method, but can in principle be generalized to other experimental setups using other polarization techniques.

nucl-ex

Performance of silicon PIN photodiodes at low temperatures and in high magnetic fields

The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sen- sitive detector operating at cryogenic temperatures (~10 K) and in magnetic fields up to 11 T was investigated, using a 207Bi conversion electron source. It was found that the detector still performs well under these conditions, with small changes in the response function being observed in high magnetic fields, e.g. a 30% to 50% decrease in energy resolution. A GEANT4 Monte Carlo simulation showed that the observed effects are mainly due to the modified trajectories of the electrons due to the influence of the magnetic field, which changes the scattering conditions, rather than to intrinsic changes of the performance of the detector itself.

nucl-ex

Development of a thermal ionizer as ion catcher

An effective ion catcher is an important part of a radioactive beam facility that is based on in-flight production. The catcher stops fast radioactive products and emits them as singly charged slow ions. Current ion catchers are based on stopping in He and H$_2$ gas. However, with increasing intensity of the secondary beam the amount of ion-electron pairs created eventually prevents the electromagnetic extraction of the radioactive ions from the gas cell. In contrast, such limitations are not present in thermal ionizers used with the ISOL production technique. Therefore, at least for alkaline and alkaline earth elements, a thermal ionizer should then be preferred. An important use of the TRI$μ$P facility will be for precision measurements using atom traps. Atom trapping is particularly possible for alkaline and alkaline earth isotopes. The facility can produce up to 10$^9$ s$^{-1}$ of various Na isotopes with the in-flight method. Therefore, we have built and tested a thermal ionizer. An overview of the operation, design, construction, and commissioning of the thermal ionizer for TRI$μ$P will be presented along with first results for $^{20}$Na and $^{21}$Na.

nucl-ex

Production and trapping of radioactive atoms at the TRI\muP facility

The structures for the TRI$μ$P facility have been completed and commissioned. At the facility radioactive nuclides are produced to study fundamental interactions and symmetries. An important feature is the possibility to trap radioactive atoms in order to obtain and hold a pure substrate-free sample for precision measurements. In the TRI$μ$P facility a production target is followed by a magnetic separator, where radioactive isotopes are produced in inverse reaction kinematics. Separation up to 99.95% could be achieved for $^{21}$Na. A novel transmitting thermal ionizing device was developed to stop the energetic isotopes. Some 50% of stopped $^{21}$Na could be extracted and transported as low energy singly charged ions into a radio frequency quadrupole cooler and buncher with 35% transmission efficiency. The ions are transported lossless via a drift tube and a low energy electrostatic beam line into the experimental setup. Such ions can be neutralized on hot metal foils and the resulting atoms can be stored in a magneto-optical trap. The functioning of that principle was demonstrated with stable Na extracted from the thermal ionizer, radioactive beams will follow next.

nucl-ex

Production of Radioactive Nuclides in Inverse Reaction Kinematics

Efficient production of short-lived radioactive isotopes in inverse reaction kinematics is an important technique for various applications. It is particularly interesting when the isotope of interest is only a few nucleons away from a stable isotope. In this article production via charge exchange and stripping reactions in combination with a magnetic separator is explored. The relation between the separator transmission efficiency, the production yield, and the choice of beam energy is discussed. The results of some exploratory experiments will be presented.

nucl-ex

Aspects of Cooling at the TRI$μ$P Facility

The Tri$μ$P facility at KVI is dedicated to provide short lived radioactive isotopes at low kinetic energies to users. It comprised different cooling schemes for a variety of energy ranges, from GeV down to the neV scale. The isotopes are produced using beam of the AGOR cyclotron at KVI. They are separated from the primary beam by a magnetic separator. A crucial part of such a facility is the ability to stop and extract isotopes into a low energy beamline which guides them to the experiment. In particular we are investigating stopping in matter and buffer gases. After the extraction the isotopes can be stored in neutral atoms or ion traps for experiments. Our research includes precision studies of nuclear $β$-decay through $β$-$ν$ momentum correlations as well as searches for permanent electric dipole moments in heavy atomic systems like radium. Such experiments offer a large potential for discovering new physics.

physics.atom-ph

Dual Magnetic Separator for TRI$μ$P

The TRI$μ$P facility, under construction at KVI, requires the production and separation of short-lived and rare isotopes. Direct reactions, fragmentation and fusion-evaporation reactions in normal and inverse kinematics are foreseen to produce nuclides of interest with a variety of heavy-ion beams from the superconducting cyclotron AGOR. For this purpose, we have designed, constructed and commissioned a versatile magnetic separator that allows efficient injection into an ion catcher, i.e., gas-filled stopper/cooler or thermal ionizer, from which a low energy radioactive beam will be extracted. The separator performance was tested with the production and clean separation of $^{21}$Na ions, where a beam purity of 99.5% could be achieved. For fusion-evaporation products, some of the features of its operation as a gas-filled recoil separator were tested.

nucl-ex