SearcharxivSearch

arXiv subjects

Eamon Egan

Publications and source records attributed to Eamon Egan.

6 recordsLinked to original sources

Continuous Ultra-Low-Frequency Solar Radio Monitoring with ALBATROS from the High Arctic

In the Canadian High Arctic, nearly five months of continuous daylight enable uninterrupted low-frequency solar monitoring. We present the first solar science results from the Array of Long Baseline Antennas for Taking Radio Observations from Seventy-Ninth Parallel (ALBATROS). This broadband radio array is designed to explore the largely uncharted radio sky below 30 MHz, where polar ionospheric conditions permit access to frequencies rarely accessible from ground-based sites. Using observations spanning 1-125 MHz, we detect bright solar radio bursts exhibiting complex spectral and polarised structure. The bursts are observed simultaneously by all eight autonomous stations, demonstrating the stability and consistency of the array. Comparison with concurrent soft X-ray measurements reveals a strong temporal correlation between the radio and X-ray emission. These observations establish ALBATROS as a new facility for ultra-low-frequency solar monitoring, opening a new window on solar radio bursts, space weather, and the dynamic heliosphere.

astro-ph.IM

A low-cost ice melt monitoring system using wind-induced motion of mass-balance stakes

Surface ablation measurements of glaciers are critical for understanding mass change over time. Mass-balance stakes are commonly used for localized measurements, with the exposed length typically measured manually at infrequent intervals. This paper presents the design and validation of new instrumentation that automates mass-balance stake readings, thus enabling continuous measurements with high temporal resolution. The instrumentation comprises readout electronics that are mounted on mass-balance stakes to measure wind-induced vibrations. The stake vibrational frequency depends sensitively on the exposed length, and changes in the measured frequency therefore probe glacier surface melt and accumulation. Initial instrumentation field tests conducted at Color Lake on Umingmat Nunaat (Axel Heiberg Island), Nunavut, demonstrate centimeter-level precision on length measurements. The instrumentation can be attached to existing mass-balance stakes and is low-cost (~ $50 USD) in comparison to many other systems that perform automated surface ablation measurements. The accessibility of this instrumentation opens new possibilities for localized, high temporal resolution measurements of glacier surface activity at any locations where mass balance stakes are deployed.

physics.ins-det

Measuring dark currents in multiple cryogenic SiPMs with sub-pA sensitivity using an automated IV multiplexer

We present the design of an automated current-voltage (IV) multiplexer (MUX) that enables accurate measurement of the dark current in cryogenic silicon photomultipliers (SiPMs), achieving a sensitivity equivalent to detecting less than one avalanche per second. Dynamic pulse-counting measurements were used as a benchmark for reconstructing the dark current in static IV measurements. The IV-MUX features 15 channels on a single board and up to seven boards can be connected in parallel under the control of one Arduino microcontroller. To minimize leakage and enhance performance, the layout includes guard rings and high-isolation relays, enabling resolution of currents as small as 49 fA. The IV-MUX can be integrated into systems designed for IV or pulse-counting measurements, enabling seamless switching between IV and pulse-counting modes. Moreover, the IV-MUX is vacuum-compatible, validated by testing an SiPM array in a cryostat. This feature reduces the need for multiple feedthroughs when testing sensor arrays in vacuum. The design is open source and can be used to facilitate rapid and automated testing of SiPMs or similar low-current devices in one measurement cycle.

physics.ins-det

First Use of GPS Satellites for Beam Calibration of Radio Dish Telescopes

We present results from the first application of the Global Navigation Satellite System (GNSS; e.g., the Global Positioning System, GPS) for radio beam calibration using a commercial GNSS receiver with the Deep Dish Development Array (D3A) at the Dominion Radio Astrophysical Observatory (DRAO). Several GNSS satellites pass through the main and sidelobes of the beam each day, enabling efficient mapping of the 2D beam structure. Due to the high SNR and abundance of GNSS satellites, we find evidence that GNSS can probe several sidelobes of the beam through repeatable measurements of the beam over several days. Over three days of measurements, the smallest observed difference in the primary beam's main lobe was 0.56 dB-Hz. We also compare our results in the sidelobes to simulations and find rough agreement in shape. When scaling the observations and simulations to match in the main lobe power levels, we find deviations in at least one of the first few nulls of approximately 5 dB or less. There is saturation in the main lobe for most satellites, which can likely be mitigated by better attenuation before the receiver input. We compare our work to other satellite systems that have been successful and are likely complementary to this technique. However, GNSS offers key advantages, including continuous transmission, broader frequency coverage relevant to CHORD, SKA-mid, and the DSA-2000, as well as more frequent satellite passes, making it a promising calibration method. These results also motivate further development of this technique for radio astronomy applications.

astro-ph.IM

Drone-Based Antenna Beam Calibration in the High Arctic

Precision calibration is a critical requirement for future ultra-low-frequency observations of the early universe. The Array of Long Baseline Antennas for Taking Radio Observations from the Seventy-Ninth Parallel (ALBATROS), a radio interferometer located in the Canadian high Arctic, is designed to map Galactic foreground emission as a pathfinder for these future experiments. Accurate antenna beam characterization at these frequencies is therefore essential, yet remains uniquely challenging. We present PteroSoar, a custom-built drone platform equipped with a calibrated radio-frequency transmitter that enables controlled, in-situ measurements of low-frequency antenna beams. As an initial demonstration, we produce a two-dimensional beam map of an ALBATROS antenna at 50~MHz to a precision of approximately $10\%$ near zenith. We identify the dominant sources of systematic uncertainty, including timing imprecision, and outline hardware and software improvements that are expected to reduce beam measurement uncertainties to below $5\%$. This target is sub-dominant to the $\sim20\%$ amplitude variability introduced by ionospheric scintillation at these frequencies, providing a practical pathway toward precision beam calibration for ALBATROS and other ultra-low-frequency radio experiments.

astro-ph.IM

Simulation Study of Photon-to-Digital Converter (PDC) Timing Specifications for LoLX Experiment

The Light only Liquid Xenon (LoLX) experiment is a prototype detector aimed to study liquid xenon (LXe) light properties and various photodetection technologies. LoLX is also aimed to quantify LXe's time resolution as a potential scintillator for 10~ps time-of-flight (TOF) PET. Another key goal of LoLX is to perform a time-based separation of Cerenkov and scintillation photons for new background rejection methods in LXe experiments. To achieve this separation, LoLX is set to be equipped with photon-to-digital converters (PDCs), a photosensor type that provides a timestamp for each observed photon. To guide the PDC design, we explore requirements for time-based Cerenkov separation. We use a PDC simulator, whose input is the light information from the Geant4-based LoLX simulation model, and evaluate the separation quality against time-to-digital converter (TDC) parameters. Simulation results with TDC parameters offer possible configurations supporting a good separation. Compared with the current filter-based approach, simulations show Cerenkov separation level increases from 54% to 71% when using PDC and time-based separation. With the current photon time profile of LoLX simulation, the results also show 71% separation is achievable with just 4 TDCs per PDC. These simulation results will lead to a specification guide for the PDC as well as expected results to compare against future PDC-based experimental measurements. In the longer term, the overall LoLX results will assist large LXe-based experiments and motivate the assembly of a LXe-based TOF-PET demonstrator system.

physics.ins-det