UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

cs.CV

Automatic spinal curvature measurement on ultrasound spine images using Faster R-CNN

Ultrasound spine imaging technique has been applied to the assessment of spine deformity. However, manual measurements of scoliotic angles on ultrasound images are time-consuming and heavily rely on raters experience. The objectives of this study are to construct a fully automatic framework based on Faster R-CNN for detecting vertebral lamina and to measure the fitting spinal curves from the detected lamina pairs. The framework consisted of two closely linked modules: 1) the lamina detector for identifying and locating each lamina pairs on ultrasound coronal images, and 2) the spinal curvature estimator for calculating the scoliotic angles based on the chain of detected lamina. Two hundred ultrasound images obtained from AIS patients were identified and used for the training and evaluation of the proposed method. The experimental results showed the 0.76 AP on the test set, and the Mean Absolute Difference (MAD) between automatic and manual measurement which was within the clinical acceptance error. Meanwhile the correlation between automatic measurement and Cobb angle from radiographs was 0.79. The results revealed that our proposed technique could provide accurate and reliable automatic curvature measurements on ultrasound spine images for spine deformities.

eess.IV

Automatic segmentation of vertebral features on ultrasound spine images using Stacked Hourglass Network

Objective: The spinous process angle (SPA) is one of the essential parameters to denote three-dimensional (3-D) deformity of spine. We propose an automatic segmentation method based on Stacked Hourglass Network (SHN) to detect the spinous processes (SP) on ultrasound (US) spine images and to measure the SPAs of clinical scoliotic subjects. Methods: The network was trained to detect vertebral SP and laminae as five landmarks on 1200 ultrasound transverse images and validated on 100 images. All the processed transverse images with highlighted SP and laminae were reconstructed into a 3D image volume, and the SPAs were measured on the projected coronal images. The trained network was tested on 400 images by calculating the percentage of correct keypoints (PCK); and the SPA measurements were evaluated on 50 scoliotic subjects by comparing the results from US images and radiographs. Results: The trained network achieved a high average PCK (86.8%) on the test datasets, particularly the PCK of SP detection was 90.3%. The SPAs measured from US and radiographic methods showed good correlation (r>0.85), and the mean absolute differences (MAD) between two modalities were 3.3{\deg}, which was less than the clinical acceptance error (5{\deg}). Conclusion: The vertebral features can be accurately segmented on US spine images using SHN, and the measurement results of SPA from US data was comparable to the gold standard from radiography.

eess.IV

Assessing Bone Quality of Spine on Children with Scoliosis Using Ultrasound Reflection FAI Method -- A Preliminary Study

Osteopenia is indicated as a common phenomenon in patients who have scoliosis. Quantitative ultrasound (QUS) has been used to assess skeletal status for decades, and recently ultrasound imaging using reflection signals from vertebra were as well applied to measure spinal curvatures on children with scoliosis. The objectives of this study are to develop a new method which can robustly extract a parameter from ultrasound spinal data for estimating bone quality of scoliotic patients and to investigate the potential for the parameter on predicting curve progression. The frequency amplitude index (FAI) was calculated based on the spectrum of the original radio frequency (RF) signals reflected from the tissue-vertebra interface. The correlation between FAI and reflection coefficient was validated using decalcified bovine bone samples in vitro, and the FAIs of scoliotic subjects were investigated in vivo referring to BMI, Cobb angles and curve progression status. The results showed that the intra-rater measures were highly reliable between different trials (ICC=0.997). The FAI value was strongly correlated to the reflection coefficient of bone tissue ($R^{2}=0.824$), and the lower FAI indicated the higher risk of curve progression for the non-mild cases. This preliminary study reported that the FAI method can provide a feasible and promising approach to assess bone quality and monitor curve progression of the patients who have AIS.

physics.med-ph