SearcharxivSearch

arXiv subjects

Edward H. Wishnow

Publications and source records attributed to Edward H. Wishnow.

4 recordsLinked to original sources

Design and Performance of the Carruthers Geocoronal Imager

The GeoCoronal Imager (GCI) onboard the Carruthers Geocorona Observatory is the primary scientific instrument of the mission. It is designed to measure far ultraviolet light at 121.6 nm (Lyman-alpha) emitted by hydrogen (H) atoms in Earth's exosphere with the sensitivity, accuracy and precision to meet the mission's scientific objectives regarding the nature of terrestrial exospheric structure and dynamics on both global and regional scales. The GCI is comprised of two co-aligned UV imaging systems. The Narrow Field Imager (NFI) acquires nearly continuous images of exospheric Lyman-alpha radiance near and above the Earth's limb at relatively high spatial and temporal resolution, while the Wide Field Imager (WFI) uses relatively higher optical sensitivity and a wider field of view to detect faint Lyman-alpha emission from the exosphere's outermost extent. Both imaging channels feature identical active pixel sensor cameras, gain-intensifiers, and 6-position optical filter wheels. This paper outlines the instrument design requirements, informed by mission science goals, as well as its performance as measured in the vacuum ultraviolet laboratory test and calibration.

astro-ph.IM

A Search for Monochromatic Light Toward the Galactic Centre

A region 140 square degrees toward the Galactic Centre was searched for monochromatic optical light, both pulses shorter than 1 sec and continuous emission. A novel instrument was constructed that acquires optical spectra of every point within 6 square degrees every second, able to distinguish lasers from astrophysical sources. The system consists of a modified Schmidt telescope, a wedge prism over the 0.28-meter aperture, and a fast CMOS camera with 9500 x 6300 pixels. During 2021, a total of 34800 exposures were obtained and analyzed for monochromatic sources, both sub-second pulses and continuous in time. No monochromatic light was found. A benchmark laser with a 10-meter aperture and located 100 light years away would be detected if it had a power more than ~60 megawatt during 1 sec, and from 1000 light years away, 6000 MW is required. This non-detection of optical lasers adds to previous optical SETI non-detections from more than 5000 nearby stars of all masses, from the Solar gravitational lens focal points of Alpha Centauri, and from all-sky searches for broadband optical pulses. These non-detections, along with those of broadband pulses, constitute a growing SETI desert in the optical domain.

astro-ph.EP

Laser Communication with Proxima and Alpha Centauri using the Solar Gravitational Lens

A search was conducted for laser signals, both sub-second pulses and continuous emission, from the regions of the sky opposite Proxima and Alpha Centauri. These regions are located at the foci of the gravitational lensing caused by the Sun, ideal for amplifying transmissions between our Solar System and those two nearest stellar neighbors. During six months in 2020 and 2021, 88000 exposures for Proxima Cen and 47000 exposures for Alpha Cen were obtained. No evidence was detected of light pulses or continuous laser emission in the wavelength range of 380 to 950 nm. We would have detected a laser having a power of just 100 Watts.

astro-ph.IM

Precise Stellar Radial Velocities of an M Dwarf with a Michelson Interferometer and a Medium-resolution Near-infrared Spectrograph

Precise near-infrared radial velocimetry enables efficient detection and transit verification of low-mass extrasolar planets orbiting M dwarf hosts, which are faint for visible-wavelength radial velocity surveys. The TripleSpec Exoplanet Discovery Instrument, or TEDI, is the combination of a variable-delay Michelson interferometer and a medium-resolution (R=2700) near-infrared spectrograph on the Palomar 200" Hale Telescope. We used TEDI to monitor GJ 699, a nearby mid-M dwarf, over 11 nights spread across 3 months. Analysis of 106 independent observations reveals a root-mean-square precision of less than 37 m/s for 5 minutes of integration time. This performance is within a factor of 2 of our expected photon-limited precision. We further decompose the residuals into a 33 m/s white noise component, and a 15 m/s systematic noise component, which we identify as likely due to contamination by telluric absorption lines. With further development this technique holds promise for broad implementation on medium-resolution near-infrared spectrographs to search for low-mass exoplanets orbiting M dwarfs, and to verify low-mass transit candidates.

astro-ph.IM