SearcharxivSearch

arXiv subjects

Edward Z. Zhang

Publications and source records attributed to Edward Z. Zhang.

3 recordsLinked to original sources

Photoacoustic Reconstruction Using Sparsity in Curvelet Frame: Image versus Data Domain

Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests near equivalence between the recovery of the initial pressure and PAT data from compressed/subsampled measurements when assuming sparsity in Curvelet frame. As the latter is computationally more tractable, investigation to which extent this equivalence holds conducted in this paper is of immediate practical significance. To this end we formulate and compare DR, a two step approach based on the recovery of the complete volume of the photoacoustic data from the subsampled data followed by the acoustic inversion, and p0R, a one step approach where the photoacoustic image (the initial pressure, p0) is directly recovered from the subsampled data. Effective representation of the photoacoustic data requires basis defined on the range of the photoacoustic forward operator. To this end we propose a novel wedge-restriction of Curvelet transform which enables us to construct such basis. Both recovery problems are formulated in a variational framework. As the Curvelet frame is heavily overdetermined, we use reweighted l1 norm penalties to enhance the sparsity of the solution. The data reconstruction problem DR is a standard compressed sensing recovery problem, which we solve using an ADMMtype algorithm, SALSA. Subsequently, the initial pressure is recovered using time reversal as implemented in the k-Wave Toolbox. The p0 reconstruction problem, p0R, aims to recover the photoacoustic image directly via FISTA, or ADMM when in addition including a non-negativity constraint. We compare and discuss the relative merits of the two approaches and illustrate them on 2D simulated and 3D real data in a fair and rigorous manner.

cs.CV

Single-shot hybrid photoacoustic-fluorescent microendoscopy through a multi-mode fiber with wavefront shaping

We present a minimally-invasive endoscope based on a multimode fiber that combines photoacoustic and fluorescence sensing. From the measurement of a transmission matrix during a prior calibration step, a focused spot is produced and raster-scanned over a sample at the distal tip of the fiber by use of a fast spatial light modulator. An ultra-sensitive fiber-optic ultrasound sensor for photoacoustic detection placed next to the fiber is combined with a photodetector to obtain both fluorescence and photoacoustic images with a distal imaging tip no larger than 250um. The high signal-to-noise ratio provided by wavefront shaping based focusing and the ultra-sensitive ultrasound sensor enables imaging with a single laser shot per pixel, demonstrating fast two-dimensional hybrid imaging of red blood cells and fluorescent beads.

physics.optics

Acoustic Wave Field Reconstruction from Compressed Measurements with Application in Photoacoustic Tomography

We present a method for the recovery of compressively sensed acoustic fields using patterned, instead of point-by-point, detection. From a limited number of such compressed measurements, we propose to reconstruct the field on the sensor plane in each time step independently assuming its sparsity in a Curvelet frame. A modification of the Curvelet frame is proposed to account for the smoothing effects of data acquisition and motivated by a frequency domain model for photoacoustic tomography. An ADMM type algorithm, SALSA, is used to recover the pointwise data in each individual time step from the patterned measurements. For photoacoustic applications, the photoacoustic image of the initial pressure is reconstructed using time reversal in ${\bf k}$-Wave Toolbox.

math.NA