SearcharxivSearch

arXiv subjects

Egor Sobolev

Publications and source records attributed to Egor Sobolev.

6 recordsLinked to original sources

Train-Resolved Statistical Recovery of Weak SAXS Signals in Liquids at the European XFEL

We present a train-resolved SAXS methodology for recovering weak scattering signals from high-repetition-rate XFEL datasets and apply it to aqueous L-cysteine solutions measured at the European XFEL. Independent scale-plus-offset fitting was performed for matched cysteine and water train pairs, followed by subtraction of transmission-matched water--water controls. The 0.5 M dataset reveals a reproducible sign-changing residual SAXS signal that increases with incident XFEL transmission and remains after removal of detector-wide scaling, additive offsets, and matched water--water control residuals. Convergence and block-averaging analyses show that the residual emerges progressively as independent train pairs are accumulated and exhibits uncertainty scaling close to the expected inverse square-root dependence on N. These results establish a statistically robust transmission-dependent residual SAXS contribution whose microscopic origin remains unresolved, while demonstrating that train-resolved observables combined with matched controls can substantially improve sensitivity to weak scattering signals in high-repetition-rate XFEL experiments.

physics.optics

Time Resolved Study of Laser Induced Ultrafast Alloying Processes in Au/Pd Core Shell Nanorods

Femtosecond laser-induced alloying presents a novel approach to modifying bimetallic systems. Visualizing ultrafast processes during laser-induced alloying is essential to uncover fundamental mechanisms associated with phase transformations, which enables precise control over material composition and structure at the atomic level. In this study, we investigated the ultrafast dynamics of laser-induced alloying of Au/Pd core-shell nanorods using a time-resolved X-ray diffraction technique at an X-ray free-electron laser facility, capturing the structural evolution from picoseconds to microsecond timescales. We found that a laser fluence threshold of ~ 48 mJ/cm2 with 800 nm excitation is sufficient for melting and subsequent alloy formation. Above this threshold, the formation of Au1.51Pd0.49 was observed, and we found that alloying is not a single-step phenomenon; instead, it is a dynamic process involving interdiffusion.

cond-mat.mtrl-sci

Single-particle incoherent diffractive imaging and amplified spontaneous emission in copper nanocubes

We demonstrate element-specific incoherent diffractive imaging (IDI) of single copper nanocubes using intensity correlations of K$\alpha$ fluorescence at a hard X-ray free-electron laser. Combining single particle diffraction classification with IDI, we retrieve the form factor of 88 nm cubes with 20 nm resolution, extending IDI to the destructive single-particle regime with a large gain in resolution. IDI visibility drops sharply above a fluence of $10^2$ J/cm$^2$, consistent with the assumption of amplified spontaneous emission. Our results reveal fundamental limits for high-fluence nanoimaging towards future single-particle X-ray imaging.

physics.optics

Nonlinear phenomena in X-ray fluorescence from single nanoparticles under extreme conditions

Materials exposed to intense femtosecond X-ray pulses with energies above their K-shell absorption edge can enter an extremely ionized state, which could give rise to nonlinear phenomena, such as saturable absorption and reverse saturable absorption. In this work, we investigate these effects on single copper nanoparticles irradiated by an X-ray free-electron laser pulse. We study the properties of the K$\alpha$ fluorescence for two different short pulse durations and three X-ray incident energies below and above the K-shell absorption edge, and correlate these with incident fluence estimates based on coherent diffraction. We observe that the incident fluence of the pulse and not its duration, is the main factor that modulates the nonlinear response, which leads to an effective shortening of the fluorescence emission. Our findings have implications for fluorescence-based methods for imaging single particles using transiently coherent fluorescence, or diffractive imaging through transient resonances.

physics.optics

Online dynamic flat-field correction for MHz Microscopy data at European XFEL

The X-ray microscopy technique at the European X-ray free-electron laser (EuXFEL), operating at a MHz repetition rate, provides superior contrast and spatial-temporal resolution compared to typical microscopy techniques at other X-ray sources. In both online visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as phase retrieval and modal decomposition. In addition, access to normalized projections during data acquisition can play an important role in decision-making and improve the quality of the data. However, the stochastic nature of XFEL sources hinders the use of existing flat-flied normalization methods during MHz X-ray microscopy experiments. Here, we present an online dynamic flat-field correction method based on principal component analysis of dynamically evolving flat-field images. The method is used for the normalization of individual X-ray projections and has been implemented as an online analysis tool at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of EuXFEL.

physics.ins-det

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

physics.ins-det