SearcharxivSearch

arXiv subjects

Elad Alon

Publications and source records attributed to Elad Alon.

5 recordsLinked to original sources

Feedforward Nonlinear Equalizer for Short- to Medium-Reach Wireline Links

This paper presents a feedforward nonlinear equalizer (FFNE) framework for short- to medium-reach wireline links that removes the feedback-timing bottleneck of decision-feedback equalizers (DFEs) while approaching the noise-margin advantage within a characterized operating region. The proposed FFNE reduces short-window maximum-likelihood sequence estimation to a compact binary decision rule, enabling a low-complexity feedforward realization without transmitter-side encoding. For the single-postcursor NRZ case, the mathematical foundation, hardware implementation, tap adaptation, statistical analysis, and equalization limit relative to an ideal 1-tap DFE are established. A window-length-3 FFNE quantifies the performance-complexity tradeoff of longer sequence windows. The framework is further extended to PAM-4 modulation and simultaneous precursor/postcursor equalization through a pattern-detection-based FFNE (PD-FFNE), which outperforms conventional FFE+DFE baselines under representative channel conditions.

eess.SP

MRDust: Wireless Implant Data Uplink & Localization via Magnetic Resonance Image Modulation

Magnetic resonance imaging (MRI) exhibits rich and clinically useful endogenous contrast mechanisms, which can differentiate soft tissues and are sensitive to flow, diffusion, magnetic susceptibility, blood oxygenation level, and more. However, MRI sensitivity is ultimately constrained by Nuclear Magnetic Resonance (NMR) physics, and its spatiotemporal resolution is limited by SNR and spatial encoding. On the other hand, miniaturized implantable sensors offer highly localized physiological information, yet communication and localization can be challenging when multiple implants are present. This paper introduces the MRDust, an active ``contrast agent" that integrates active sensor implants with MRI, enabling the direct encoding of highly localized physiological data into MR images to augment the anatomical images. MRDust employs a micrometer-scale on-chip coil to actively modulate the local magnetic field, enabling MR signal amplitude and phase modulation for digital data transmission. Since MRI inherently captures the anatomical tissue structure, this method has the potential to enable simultaneous data communication, localization, and image registration with multiple implants. This paper presents the underlying physical principles, design tradeoffs, and design methodology for this approach. To validate the concept, a 900 $\times$ 990 $\mu$m$^2$ chip was designed using TSMC 28 nm technology, with an on-chip coil measuring 630 $\mu$m in diameter. The chip was tested with custom hardware in an MR750W GE3T MRI scanner. Successful voxel amplitude modulation is demonstrated with Spin-Echo Echo-Planar-Imaging (SE-EPI) sequence, achieving a contrast-to-noise ratio (CNR) of 25.58 with a power consumption of 130 $\mu$W.

eess.SY

Optimizing the LO Distribution Architecture of mm-Wave Massive MIMO Receivers

Wireless networks at millimeter wavelengths have significant implementation difficulties. The path loss at these frequencies naturally leads us to consider antenna arrays with many elements. In these arrays, local oscillator (LO) generation is particularly challenging since the LO specifications affect the system architecture, signal processing design, and circuit implementation. We thoroughly analyze the effect of LO architecture design choices on the performance of a mm-wave massive MIMO uplink. This investigation focuses on the tradeoffs involved in centralized and distributed LO generation, correlated and uncorrelated phase noise sources, and the bandwidths of PLLs and carrier recovery loops. We show that, from both a performance and implementation complexity standpoint, the optimal LO architecture uses several distributed subarrays locked to a single intermediate-frequency reference in the low GHz range. Additionally, we show that the choice of PLL and carrier recovery loop bandwidths strongly affects the performance; for typical system parameters, loop bandwidths on the order of tens of MHz achieve SINRs suitable for high-order constellations. Finally, we present system simulations incorporating a complete model of the LO generation system and consider the case of a 128-element array with 16x-spatial multiplexing and a 2 GHz channel bandwidth at 75 GHz carrier. Using our optimization procedure we show that the system can support 16-way spatial multiplexing with 64-QAM modulation.

eess.SP

Physical Principles for Scalable Neural Recording

Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely new approaches may be required, motivating an analysis of the fundamental physical constraints on the problem. We outline the physical principles governing brain activity mapping using optical, electrical,magnetic resonance, and molecular modalities of neural recording. Focusing on the mouse brain, we analyze the scalability of each method, concentrating on the limitations imposed by spatiotemporal resolution, energy dissipation, and volume displacement. We also study the physics of powering and communicating with microscale devices embedded in brain tissue.

q-bio.NC

Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces

A major hurdle in brain-machine interfaces (BMI) is the lack of an implantable neural interface system that remains viable for a lifetime. This paper explores the fundamental system design trade-offs and ultimate size, power, and bandwidth scaling limits of neural recording systems built from low-power CMOS circuitry coupled with ultrasonic power delivery and backscatter communication. In particular, we propose an ultra-miniature as well as extremely compliant system that enables massive scaling in the number of neural recordings from the brain while providing a path towards truly chronic BMI. These goals are achieved via two fundamental technology innovations: 1) thousands of 10 - 100 μm scale, free-floating, independent sensor nodes, or neural dust, that detect and report local extracellular electrophysiological data, and 2) a sub-cranial interrogator that establishes power and communication links with the neural dust.

q-bio.NC