Searcharxiv⌕ Search

arXiv subjects

Elena De Momi

Publications and source records attributed to Elena De Momi.

At least 19 recordsLinked to original sources

Safety-Constrained Model Predictive Control for an Omnidirectional Walking Assistive Robot Using Control Barrier Function

Providing safe and effective mobility assistance plays a crucial role in restoring independence and enhancing the quality of life for individuals with motor impairments. In this context, robotic walking assistive devices have recently emerged as promising solutions to provide physically compliant interaction while ensuring user safety and support. This paper presents a novel control framework for an omnidirectional Walking Assistive Robot (I-WANDER) that integrates a Control Barrier Function (CBF) formulation into a Model Predictive Control (MPC) scheme to explicitly enforce collision-avoidance safety constraints while optimizing for energy efficiency and smooth human-robot collaboration. The method was experimentally evaluated with 12 healthy participants performing two different walking tasks using both the proposed CBF-based MPC controller (CB-MPC) and a variable admittance controller (AC). The first task involved structured navigation through a U-shaped corridor, whereas the second consisted of a single-obstacle avoidance task performed blindfolded to ensure the obstacle was unexpected. Comparative results show that the CB-MPC architecture significantly reduces energy consumption and mechanical work (p < 0.01) without compromising motion smoothness, while also decreasing the number of obstacle collisions. Overall, the findings highlight the potential of the proposed control architecture to enhance both safety and efficiency in robotic walking assistance.

cs.RO↗

Evidence-Based Text-Conditioned 3D CT Synthesis for Ovarian Cancer

Ovarian cancer is frequently diagnosed at an advanced stage, making preoperative contrast-enhanced computed tomography (CT) central to staging and surgical planning; yet the scarcity of annotated imaging data, compounded by privacy regulations, limits the development of generalizable computational models in this domain. Text-conditioned 3D CT synthesis has shown promise, but existing pipelines depend on paired radiology reports and have been evaluated only on chest CT. We propose OvESyn (Ovarian Evidence-based Synthesis), a framework that constructs standardized Findings and Impression sections directly from CT-derived imaging descriptors and routine clinical metadata, without any original radiology report, and uses them to condition a latent diffusion model adapted to 493 high-grade serous ovarian carcinoma patients. This is the first text-conditioned 3D CT synthesis framework adapted to an abdomino-pelvic oncologic setting. A systematic ablation over two adaptation axes, vision-language encoder alignment and generator fine-tuning, identifies generator domain adaptation as the operative mechanism for crossing the domain gap and establishing the target anatomy: without it, synthesis remains anchored to the thoracic pretraining domain, with Precision and Recall collapsing to zero and FID2.5D exceeding 140, regardless of encoder alignment. Encoder alignment instead refines intensity and fine detail. The full OvESyn attains the best distributional and intensity fidelity (FID2.5D 29.35, Precision 0.671, Wasserstein-1 0.044), while the generator-only variant maximizes coverage (Recall 0.645), reflecting a fidelity/coverage trade-off governed by encoder adaptation. Requiring only automatic segmentations and routine preoperative metadata, OvESyn supports transferability to report-scarce settings and provides a foundation for synthetic cohort generation in abdomino-pelvic oncologic imaging.

cs.CV↗

Evaluation of Augmented Reality-based Intuitive Interface for Robot-Assisted Transesophageal Echocardiography: A User Study

TransEsophageal Echocardiography (TEE) is essential for diagnosing and guiding Structural Heart Disease (SHD) interventions. However, manual TEE manipulation demands significant operator expertise, is physically demanding, and exposes clinicians to radiation when performed alongside fluoroscopy. Robotic-assisted TEE systems have been introduced to improve probe handling and reduce operator fatigue, yet the design of intuitive and effective user interfaces remains an open challenge. This study presents and evaluates a model-enhanced, Augmented Reality (AR)-based intuitive interface for robot-assisted TEE, designed to improve spatial awareness and control intuitiveness. A robotic TEE platform integrated with electromagnetic tracking and a virtual simulator was used to compare three user interfaces differing in visualization and interaction modalities: 2D jointlevel (2D-JI), 3D joint-level (3D-JI), and 3D tip-level (3D-TI). Thirty six participants performed standardized navigation tasks to reproduce target echocardiographic views, with performance assessed via position and orientation errors, completion time, and NASA-TLX workload scores. Results show that 3D visualization significantly improved spatial accuracy, reducing median position error from 13 mm to 3 mm and halving the orientation error compared with the 2D interface. Tip-level interaction yielded a further 50% reduction in orientation error and reduced interuser variability relative to joint-level control. Overall, the 3D-TI configuration, combining immersive visualization with direct tip-level control, proved the most effective and ergonomic interface, supporting the integration of AR-based visualization and intuitive control paradigms into next-generation robotic TEE systems to enhance operator performance and procedural safety.

cs.RO↗

A Lightweight Fiducial-Based Pipeline for 3D Hyperspectral Mapping of ex-vivo Lumpectomy Specimens

Hyperspectral Imaging (HSI) is a promising modality for intraoperative assessment of resection margins in Breast-Conserving Surgery (BCS), but its clinical translation requires aligning the inherently 2D spectral information onto the 3D shape of the excised tissue so that suspicious regions can be precisely localized for targeted follow-up. We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen from a set of consumer-camera RGB images and a single top-down HSI acquisition. The 3D geometry is reconstructed with a deep-learning Structure-from-Motion backbone, stabilized in a metric reference frame by a custom bundle adjustment that enforces consistency on the corners of four ArUco markers placed around the specimen. The HSI cube is then registered to the reconstruction without recovering the HSI camera pose: the markers, visible in both modalities, define 16 corner correspondences that drive a planar homography, and 3D coordinates are recovered by lookup on an orthographically rendered depth map. Evaluated on two ex-vivo lumpectomy specimens, the pipeline achieves a median 3D registration error below 1~mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware. These results support the feasibility of integrating HSI-guided spatial localization into intraoperative margin assessment workflows for breast-conserving surgery.

cs.CV↗

Predicting Response to Neoadjuvant Chemotherapy in Ovarian Cancer from CT Baseline Using Multi-Loss Deep Learning

Ovarian cancer is the most lethal gynecologic malignancy: around 60% of patients are diagnosed at an advanced stage, with an associated 5-year survival rate of about 30%. Early identification of non-responders to neoadjuvant chemotherapy remains a key unmet need, as it could prevent ineffective therapy and avoid delays in optimal surgical management. This work proposes a non-invasive deep learning framework to predict neoadjuvant chemotherapy response from pre-treatment contrast-enhanced CT by leveraging automatically derived 3D lesion masks. The approach encodes axial slices with a partially fine-tuned pretrained image encoder and aggregates slice-level representations into a volumetric embedding through an attention-based module. Training combines classification loss with supervised contrastive regularization and hard-negative mining to improve separation between ambiguous responders and non-responders. The method was developed on a retrospective single-center cohort from the European Institute of Oncology (Milan, IT), including 280 eligible patients (147 responder, 133 non-responder). On the test cohort, the model achieved a ROC-AUC of 0.73 (95% CI: 0.58-0.86) and an F1-score of 0.70 (95% CI: 0.56-0.82). Overall, these results suggest that the proposed architecture learns clinically relevant predictive patterns and provides a robust foundation for an imaging-based stratification tool.

cs.CV↗

When to Trust the Answer: Question-Aligned Semantic Nearest Neighbor Entropy for Safer Surgical VQA

Safety and reliability are critical for deploying visual question answering (VQA) systems in surgery, where incorrect or ambiguous responses can cause patient harm. A key limitation of existing uncertainty estimation methods, such as Semantic Nearest Neighbor Entropy (SNNE), is that they do not explicitly account for the conditioning question. As a result, they may assign high confidence to answers that are semantically consistent yet misaligned with the clinical question, especially under variation in question phrasing. We propose Question-Aligned Semantic Nearest Neighbor Entropy (QA-SNNE), a black-box uncertainty estimator that incorporates question-answer alignment into semantic entropy through bilateral gating. QA-SNNE measures uncertainty by weighting pairwise semantic similarities among sampled answers according to their relevance to the question, using embedding-based, entailment-based, or cross-encoder alignment strategies. To assess robustness to language variation, we construct an out-of-template rephrased version of a benchmark surgical VQA dataset, where only the question wording is modified while images and ground-truth answers remain unchanged. We evaluate QA-SNNE on five VQA models across two benchmark surgical VQA datasets in both zero-shot and parameter-efficient fine-tuned (PEFT) settings, including out-of-template questions. QA-SNNE improves AUROC on EndoVis18-VQA for two of three zero-shot models in-template (e.g., +15% for Llama3.2 and +21% for Qwen2.5) and achieves up to +8% AUROC improvement under out-of-template rephrasing, with mixed results on external validation. Overall, QA-SNNE provides a practical, model-agnostic safeguard for surgical VQA by linking semantic uncertainty to question relevance.

cs.CV↗

SurgViVQA: Temporally-Grounded Video Question Answering for Surgical Scene Understanding

Video Question Answering (VideoQA) in the surgical domain aims to enhance intraoperative understanding by enabling AI models to reason over temporally coherent events rather than isolated frames. Current approaches are limited to static image features, and available datasets often lack temporal annotations, ignoring the dynamics critical for accurate procedural interpretation. We propose SurgViVQA, a surgical VideoQA model that extends visual reasoning from static images to dynamic surgical scenes. It uses a Masked Video--Text Encoder to fuse video and question features, capturing temporal cues such as motion and tool--tissue interactions, which a fine-tuned large language model (LLM) then decodes into coherent answers. To evaluate its performance, we curated REAL-Colon-VQA, a colonoscopic video dataset that includes motion-related questions and diagnostic attributes, as well as out-of-template questions with rephrased or semantically altered formulations to assess model robustness. Experimental validation on REAL-Colon-VQA and the public EndoVis18-VQA dataset shows that SurgViVQA outperforms existing image-based VQA benchmark models, particularly in keyword accuracy, improving over PitVQA by +11\% on REAL-Colon-VQA and +9\% on EndoVis18-VQA. A perturbation study on the questions further confirms improved generalizability and robustness to variations in question phrasing. SurgViVQA and the REAL-Colon-VQA dataset provide a framework for temporally-aware understanding in surgical VideoQA, enabling AI models to interpret dynamic procedural contexts more effectively. Code and dataset available at https://github.com/madratak/SurgViVQA.

cs.CV↗

Vision Transformers for Preoperative CT-Based Prediction of Histopathologic Chemotherapy Response Score in High-Grade Serous Ovarian Carcinoma

Purpose. High-grade serous ovarian carcinoma (HGSOC) is characterized by pronounced biological and spatial heterogeneity and is frequently diagnosed at an advanced stage. Neoadjuvant chemotherapy (NACT) followed by delayed primary surgery is commonly employed in patients unsuitable for primary cytoreduction. The Chemotherapy Response Score (CRS) is a validated histopathological biomarker of response to NACT, but it is only available postoperatively. In this study, we investigate whether pre-treatment computed tomography (CT) imaging and clinical data can be used to predict CRS as an investigational decision-support adjunct to inform multidisciplinary team (MDT) discussions regarding expected treatment response. Methods. We proposed a 2.5D multimodal deep learning framework that processes lesion-dense omental slices using a pre-trained Vision Transformer encoder and integrates the resulting visual representations with clinical variables through an intermediate fusion module to predict CRS. Results. Our multimodal model, integrating imaging and clinical data, achieved a ROC-AUC of 0.95 alongside 95% accuracy and 80% precision on the internal test cohort (IEO, n=41 patients). On the external test set (OV04, n=70 patients), it achieved a ROC-AUC of 0.68, alongside 67% accuracy and 75% precision. Conclusion. These preliminary results demonstrate the feasibility of transformer-based deep learning for preoperative prediction of CRS in HGSOC using routine clinical data and CT imaging. As an investigational, pre-treatment decision-support tool, this approach may assist MDT discussions by providing early, non-invasive estimates of treatment response.

cs.CV↗

Adapting Foundation Models for Annotation-Efficient Adnexal Mass Segmentation in Cine Images

Adnexal mass evaluation via ultrasound is a challenging clinical task, often hindered by subjective interpretation and significant inter-observer variability. While automated segmentation is a foundational step for quantitative risk assessment, traditional fully supervised convolutional architectures frequently require large amounts of pixel-level annotations and struggle with domain shifts common in medical imaging. In this work, we propose a label-efficient segmentation framework that leverages the robust semantic priors of a pretrained DINOv3 foundational vision transformer backbone. By integrating this backbone with a Dense Prediction Transformer (DPT)-style decoder, our model hierarchically reassembles multi-scale features to combine global semantic representations with fine-grained spatial details. Evaluated on a clinical dataset of 7,777 annotated frames from 112 patients, our method achieves state-of-the-art performance compared to established fully supervised baselines, including U-Net, U-Net++, DeepLabV3, and MAnet. Specifically, we obtain a Dice score of 0.945 and improved boundary adherence, reducing the 95th-percentile Hausdorff Distance by 11.4% relative to the strongest convolutional baseline. Furthermore, we conduct an extensive efficiency analysis demonstrating that our DINOv3-based approach retains significantly higher performance under data starvation regimes, maintaining strong results even when trained on only 25% of the data. These results suggest that leveraging large-scale self-supervised foundations provides a promising and data-efficient solution for medical image segmentation in data-constrained clinical environments. Project Repository: https://github.com/FrancescaFati/MESA

cs.CV↗

Off-Axis Compliant RCM Joint with Near-Isotropic Stiffness and Minimal Parasitic Error

This paper presents an off-axis, monolithic compliant Remote Center of Motion (RCM) joint for neuroendoscopic manipulation, combining near-isotropic stiffness with minimal parasitic motion. Based on the Tetra II concept, the end-effector is placed outside the tetrahedral flexure to improve line of sight, facilitate sterilization, and allow rapid tool release. Design proceeds in two stages: mobility panels are sized with a compliance-based isotropy objective, then constraining panels are synthesized through finite-element feasibility exploration to trade stiffness isotropy against RCM drift. The joint is modeled with beam elements and validated via detailed finite-element analyses, including fatigue-bounded stress constraints. A PA12 prototype is fabricated by selective laser sintering and characterized on a benchtop: a 2 N radial load is applied at the end-effector while a 6-DOF electromagnetic sensor records pose. The selected configuration produces a stiffness-ellipse principal axis ratio (PAR) of 1.37 and a parasitic-to-useful rotation ratio (PRR) of 0.63%. Under a 4.5° commanded rotation, the predicted RCM drift remains sub-millimetric (0.015-0.172 mm). Fatigue analysis predicts a usable rotational workspace of 12.1°-34.4° depending on direction. Experiments reproduce the simulated directional stiffness trend with typical deviations of 6-30%, demonstrating a compact, fabrication-ready RCM module for constrained surgical access.

cs.RO↗

TemporalDoRA: Temporal PEFT for Robust Surgical Video Question Answering

Surgical Video Question Answering (VideoQA) requires accurate temporal grounding while remaining robust to natural variation in how clinicians phrase questions, where linguistic bias can arise. Standard Parameter Efficient Fine Tuning (PEFT) methods adapt pretrained projections without explicitly modeling frame-to-frame interactions within the adaptation pathway, limiting their ability to exploit sparse temporal evidence. We introduce TemporalDoRA, a video-specific PEFT formulation that extends Weight-Decomposed Low-Rank Adaptation by (i) inserting lightweight temporal Multi-Head Attention (MHA) inside the low-rank bottleneck of the vision encoder and (ii) selectively applying weight decomposition only to the trainable low-rank branch rather than the full adapted weight. This design enables temporally-aware updates while preserving a frozen backbone and stable scaling. By mixing information across frames within the adaptation subspace, TemporalDoRA steers updates toward temporally consistent visual cues and improves robustness with minimal parameter overhead. To benchmark this setting, we present REAL-Colon-VQA, a colonoscopy VideoQA dataset with 6,424 clip--question pairs, including paired rephrased Out-of-Template questions to evaluate sensitivity to linguistic variation. TemporalDoRA improves Out-of-Template performance, and ablation studies confirm that temporal mixing inside the low-rank branch is the primary driver of these gains. We also validate on EndoVis18-VQA adapted to short clips and observe consistent improvements on the Out-of-Template split. Code and dataset available at~\href{https://anonymous.4open.science/r/TemporalDoRA-BFC8/}{Anonymous GitHub}.

cs.CV↗

RealSynCol: a high-fidelity synthetic colon dataset for 3D reconstruction applications

Deep learning has the potential to improve colonoscopy by enabling 3D reconstruction of the colon, providing a comprehensive view of mucosal surfaces and lesions, and facilitating the identification of unexplored areas. However, the development of robust methods is limited by the scarcity of large-scale ground truth data. We propose RealSynCol, a highly realistic synthetic dataset designed to replicate the endoscopic environment. Colon geometries extracted from 10 CT scans were imported into a virtual environment that closely mimics intraoperative conditions and rendered with realistic vascular textures. The resulting dataset comprises 28\,130 frames, paired with ground truth depth maps, optical flow, 3D meshes, and camera trajectories. A benchmark study was conducted to evaluate the available synthetic colon datasets for the tasks of depth and pose estimation. Results demonstrate that the high realism and variability of RealSynCol significantly enhance generalization performance on clinical images, proving it to be a powerful tool for developing deep learning algorithms to support endoscopic diagnosis.

cs.CV↗

UnReflectAnything: RGB-Only Highlight Removal by Rendering Synthetic Specular Supervision

Specular highlights distort appearance, obscure texture, and hinder geometric reasoning in both natural and surgical imagery. We present UnReflectAnything, an RGB-only framework that removes highlights from a single image by predicting a highlight map together with a reflection-free diffuse reconstruction. The model uses a frozen vision transformer encoder to extract multi-scale features, a lightweight head to localize specular regions, and a token-level inpainting module that restores corrupted feature patches before producing the final diffuse image. To overcome the lack of paired supervision, we introduce a Virtual Highlight Synthesis pipeline that renders physically plausible specularities using monocular geometry, Fresnel-aware shading, and randomized lighting which enables training on arbitrary RGB images with correct geometric structure. UnReflectAnything generalizes across natural and surgical domains where non-Lambertian surfaces and non-uniform lighting create severe highlights and it achieves competitive performance with state-of-the-art results on several benchmarks. Project Page: https://alberto-rota.github.io/UnReflectAnything/

cs.CV↗

Self-Supervised Contrastive Embedding Adaptation for Endoscopic Image Matching

Accurate spatial understanding is essential for image-guided surgery, augmented reality integration and context awareness. In minimally invasive procedures, where visual input is the sole intraoperative modality, establishing precise pixel-level correspondences between endoscopic frames is critical for 3D reconstruction, camera tracking, and scene interpretation. However, the surgical domain presents distinct challenges: weak perspective cues, non-Lambertian tissue reflections, and complex, deformable anatomy degrade the performance of conventional computer vision techniques. While Deep Learning models have shown strong performance in natural scenes, their features are not inherently suited for fine-grained matching in surgical images and require targeted adaptation to meet the demands of this domain. This research presents a novel Deep Learning pipeline for establishing feature correspondences in endoscopic image pairs, alongside a self-supervised optimization framework for model training. The proposed methodology leverages a novel-view synthesis pipeline to generate ground-truth inlier correspondences, subsequently utilized for mining triplets within a contrastive learning paradigm. Through this self-supervised approach, we augment the DINOv2 backbone with an additional Transformer layer, specifically optimized to produce embeddings that facilitate direct matching through cosine similarity thresholding. Experimental evaluation demonstrates that our pipeline surpasses state-of-the-art methodologies on the SCARED datasets improved matching precision and lower epipolar error compared to the related work. The proposed framework constitutes a valuable contribution toward enabling more accurate high-level computer vision applications in surgical endoscopy.

cs.CV↗

Physiological Measures of the Mental Workload in Users of a Lower Limb Exosuit: A Comparison of Subjective and Objective Metrics

Lower-limb exosuits are particularly relevant for individuals with some degree of mobility impairment, such as post-stroke patients or older adults with reduced movement capabilities. This study aims to investigate the mental workload (MWL) assessment of XoSoft, a lower-limb soft exoskeleton, using and comparing subjective and objective physiological metrics. The NASA-TLX questionnaire, the average percentage change in pupil size (APCPS), and the Baevsky stress index (SI) are compared. The experiments were conducted on 18 healthy subjects while walking and involved mathematical tasks to create a double-task condition. The results show a complex interaction between task difficulty, exoskeleton activation, and pupillary dynamics, suggesting that the subject might reach a saturated condition under a high mental load. Besides, the data indicate that pupil diameter may be an objective mental workload indicator that correlates with subjective NASA-TLX questionnaires. The discordant indications from the stress index suggest how different metrics of the ocular and cardiac levels respond differently to various stimuli and dynamics. Research has also revealed ocular asymmetry, with the right eye more sensitive to cognitive load.

eess.SP↗

Glioblastoma Overall Survival Prediction With Vision Transformers

Glioblastoma is one of the most aggressive and common brain tumors, with a median survival of 10-15 months. Predicting Overall Survival (OS) is critical for personalizing treatment strategies and aligning clinical decisions with patient outcomes. In this study, we propose a novel Artificial Intelligence (AI) approach for OS prediction using Magnetic Resonance Imaging (MRI) images, exploiting Vision Transformers (ViTs) to extract hidden features directly from MRI images, eliminating the need of tumor segmentation. Unlike traditional approaches, our method simplifies the workflow and reduces computational resource requirements. The proposed model was evaluated on the BRATS dataset, reaching an accuracy of 62.5% on the test set, comparable to the top-performing methods. Additionally, it demonstrated balanced performance across precision, recall, and F1 score, overcoming the best model in these metrics. The dataset size limits the generalization of the ViT which typically requires larger datasets compared to convolutional neural networks. This limitation in generalization is observed across all the cited studies. This work highlights the applicability of ViTs for downsampled medical imaging tasks and establishes a foundation for OS prediction models that are computationally efficient and do not rely on segmentation.

cs.CV↗

Impact of a Lower Limb Exosuit Anchor Points on Energetics and Biomechanics

Anchor point placement is a crucial yet often overlooked aspect of exosuit design since it determines how forces interact with the human body. This work analyzes the impact of different anchor point positions on gait kinematics, muscular activation and energetic consumption. A total of six experiments were conducted with 11 subjects wearing the XoSoft exosuit, which assists hip flexion in five configurations. Subjects were instrumented with an IMU-based motion tracking system, EMG sensors, and a mask to measure metabolic consumption. The results show that positioning the knee anchor point on the posterior side while keeping the hip anchor on the anterior part can reduce muscle activation in the hip flexors by up to 10.21\% and metabolic expenditure by up to 18.45\%. Even if the only assisted joint was the hip, all the configurations introduced changes also in the knee and ankle kinematics. Overall, no single configuration was optimal across all subjects, suggesting that a personalized approach is necessary to transmit the assistance forces optimally. These findings emphasize that anchor point position does indeed have a significant impact on exoskeleton effectiveness and efficiency. However, these optimal positions are subject-specific to the exosuit design, and there is a strong need for future work to tailor musculoskeletal models to individual characteristics and validate these results in clinical populations.

physics.med-ph↗

Implementation and Assessment of an Augmented Training Curriculum for Surgical Robotics

The integration of high-level assistance algorithms in surgical robotics training curricula may be beneficial in establishing a more comprehensive and robust skillset for aspiring surgeons, improving their clinical performance as a consequence. This work presents the development and validation of a haptic-enhanced Virtual Reality simulator for surgical robotics training, featuring 8 surgical tasks that the trainee can interact with thanks to the embedded physics engine. This virtual simulated environment is augmented by the introduction of high-level haptic interfaces for robotic assistance that aim at re-directing the motion of the trainee's hands and wrists toward targets or away from obstacles, and providing a quantitative performance score after the execution of each training exercise.An experimental study shows that the introduction of enhanced robotic assistance into a surgical robotics training curriculum improves performance during the training process and, crucially, promotes the transfer of the acquired skills to an unassisted surgical scenario, like the clinical one.

cs.RO↗