Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs

Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI.

physics.med-ph↗

First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.

physics.med-ph↗

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.

physics.med-ph↗

Feasibility studies of dark photon searches with the J-PET detector

The positronium, a bound state of electron and positron is a unique system to perform highly precise tests, due to no hadronic background and precise Quantum Electrodynamics (QED) predictions. Being a system of lepton and antilepton, its properties are precisely described by QED in the Standard Model (SM). The final events topology can be simulated using Monte Carlo techniques. The J-PET detector is a multi-purpose, large acceptance system that is very well-suitable to the studies of positronium decay due to its excellent angular (1$^o$) and timing resolutions. \\ We present preliminary results on the feasibility of searching for Dark Matter (DM) candidates in the decay o-Ps $\rightarrow$ invisible with the J-PET, which is well suited for the detection of positronium decay products. Toy Monte Carlo simulations have been prepared to incorporate DM decay models to the o-Ps decay expectations in order to assess the detector capabilities to search for such an elusive component of our Universe.

nucl-ex↗

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph↗

B boson search at KLOE/KLOE-2

Following the many contributions, KLOE-2 has done to Dark Matter (DM) searches, an alternative model, where the Dark Force mediator is a hypothetical leptophobic B boson, in contra-position to the U boson or "dark photon", is investigated. The B boson couples mainly to quarks and it can be searched in the Phi decay to η-B where B will decay in π0-γ. So far, investigation of the π0 -γ invariant mass shows no clear structure belonging to the signal of the DM mediator, hence, an upper limit in the number of events at 90% with CLs the technique will be established for the decay.

hep-ex↗

Physics Beyond the Standard Model with the J-PET detector

The Positronium (Ps) system, a bound state of an electron and a positron, is suitable for testing the predictions of quantum electrodynamics (QED), since its properties can be perturbatively calculated to high accuracy and, unlike the hydrogen system, is not affected by the finite size or QCD effects at the current experimental precision level. This makes the Ps atom a good laboratory to test the Fundamental Symmetries of Physics and also search for new particles not included in the Standard Model (SM) of physics. On one hand, time reversal (T) and CP symmetry violation have never been observed in pure leptonic systems like the Ps atom, and the current experimental limits for CP and CPT violation in the decays of Ps is currently set at the level of 10^-3, while for C violation are at the level of 10^-7. These limits are still six and two orders of magnitude lower than the expected precision of 10^-9 set by photon-photon interactions. Secondly, experiments searching for invisible decays of the Ps triplet state, the ortho-Positronium (o-Ps), which mainly decays to three photons, are being conducted, since they are sensitive to new physics scenarios, e.g. Mirror Matter (MM), a suitable Dark Matter candidate, proposed to restore parity (P) violation. By performing a high precision measurement of the o-Ps lifetime, the accuracy of the present QED calculations can be tested and a search for the invisible decays of the o-Ps can be performed. These studies are conducted with the novel total-body Positron-Electron Tomography (PET) scanner at the JagiellonianUniversity.

nucl-ex↗

The KLOE-2 experiment: overview of recent results

The KLOE detector at the DA$Φ$NE $ϕ$-factory has been operating in two periods from 2001 to 2006 and from 2014 to 2018 collecting a large sample of $ϕ$-meson decays. This allowed to perform precision measurements and studies of fundamental symmetries, and searches of New Physics phenomena. In this overview, the results of KLOE and KLOE-2 Collaborations are presented. The most recent results from the KLOE experiment are discussed, covering: the measurement of the running fine-structure constant $α_{em}$, the Dalitz plot measurement of $η\rightarrow π^+π^-π^0$, the search of a U boson, tests of discrete symmetries and quantum decoherence.

hep-ex↗

Dark Forces Searches at KLOE-2

Direct searches of dark matter are performed at accelerator facilities. The existence of a new vector boson has been postulated in different scenarios where in the most basic scheme the coupling to the SM can be achieved via a kinetic mixing term due to the U boson. The KLOE experiment at DA$ϕ$NE searched for the U boson both in Dalitz decays of the $ϕ$ meson and in continuum events. For all of these searches an upper limit for the U boson coupling $ε^{2}$ has been established in the mass range $50 \, \text{MeV} < m_U < 1000\,\text{MeV}$. A summary of the different models and searches along with results are presented.