SearcharxivSearch

arXiv subjects

Eleonora Capocasa

Publications and source records attributed to Eleonora Capocasa.

11 recordsLinked to original sources

Improving Beam Quality in Gravitational-Wave Interferometers Illuminated by Higher-Order Laguerre-Gaussian Modes

Higher-order Laguerre-Gaussian (LG) laser modes have been proposed to reduce test-mass thermal noise in laser interferometric gravitational-wave detectors, owing to their more homogeneous intensity profiles compared to the currently employed fundamental Gaussian beam. However, LG beams such as the LG$_{3,3}$ mode suffer significant beam quality degradation in Fabry-Perot arm cavities in GW detectors with realistic state-of-the-art mirror surface figure errors, due to scattering into degenerate modes of the same order, which are resonantly enhanced by shared cavity resonance conditions. In this work, we investigate an alternative ''donut-shaped'' LG$_{0,\ell}$-like mode, specifically the LG$_{0,6}$ mode, and demonstrate strategies to improve its performance. These include the introduction of a tailored circular mirror mask with anti-reflective coating in the central region, which selectively increases the losses of parasitic degenerate modes while minimally impacting the LG$_{0,6}$ mode due to its limited overlap with the masked area. We further assess the marginal benefits of anticipated improvements in mirror surface figure errors and the potential reduction of cavity finesse. We demonstrate that these strategies can reduce the average contrast defect by more than two orders of magnitude and lower the mode loss by nearly a factor of five, achieving performance at or below the typical values observed in current detectors. This work opens up new research and development pathways for employing LG$_{0,\ell}$-type modes that achieve significant thermal noise reduction while maintaining beam quality and optical performance comparable to current gravitational-wave interferometers.

astro-ph.IM

Demonstration of length control for a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.

physics.ins-det

Simultaneous Misalignment and Mode Mismatch Sensing in Optical Cavities Using Intensity-Only Measurements

Precise sensing and control of spatial mode content is essential for the performance of precision optical systems, particularly interferometric gravitational-wave detectors, where misalignment and mode mismatch can lead to significant optical losses and degraded quantum noise suppression. Conventional approaches, including heterodyne wavefront sensing and phase camera techniques, are effective but can be limited by hardware complexity and systematic uncertainties arising from restricted reference-beam overlap. This paper presents a novel two-step deep learning pipeline for robust beam diagnostics based solely on beam intensity images. In the first stage, a multi-intensity-image convolutional neural network (CNN) performs accurate mode decomposition, recovering the complex modal content of distorted beams. In the second stage, the predicted mode coefficients are fed into a downstream regression network that simultaneously estimates all eight degrees of freedom (DoFs) associated with misalignment and mode mismatch, including beam tilt, lateral offset, and waist size and position mismatches in both transverse directions. The proposed CNN-based framework achieves a mean absolute error (MAE) of 0.0034 in the mode decomposition stage, which propagates to a total MAE of 0.0062 in the recovered beam imperfection parameters at the final stage. This corresponds to an average residual optical loss of 39 ppm per DoF (310 ppm total). This approach relies only on standard CCD imaging and is robust to random intensity noise, eliminating the need for complex interferometric hardware. The results demonstrate that the proposed deep learning pipeline enables real-time, high-accuracy wavefront sensing and mode-mismatch diagnostics, providing a scalable and hardware-efficient tool for improving the stability and sensitivity of precision optical systems.

astro-ph.IM

Performance of multiple filter-cavity schemes for frequency-dependent squeezing in gravitational-wave detectors

Gravitational-wave detectors use state-of-the-art quantum technologies to reduce the noise induced by vacuum fluctuations, via injection of squeezed states of light. Future detectors, such as Einstein Telescope, may require the use of two filter cavities or a 3-mirror coupled filter cavity to achieve a complex rotation of the squeezing ellipse, in order to reduce the quantum noise over the whole detector bandwidth. In this work, we compare the theoretical feasibility and performances of these two optical layouts and their resilience with respect to different degradation sources (optical losses, mismatching, locking precision), analytically and numerically. We extend previous analysis on squeezing degradation and find that the coupled cavity scheme provides similar or better performances than the two-cavity option, in terms of resilience with respect to imperfections and optical losses. We further highlight the role of mode-mismatch phases in limiting squeezing. Finally, we propose a possible two-step implementation scheme for Einstein Telescope using a single filter cavity that can be possibly upgraded into a coupled filter cavity.

gr-qc

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det

Control of a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, frequency-dependent squeezed vacuum states realized using a filter cavity is a mature technique and will be implemented in Advanced LIGO and Advanced Virgo from the fourth observation run. To obtain the benefit of frequency-dependent squeezing, detuning and alignment of the filter cavity with respect to squeezed vacuum states must be controlled accurately. To this purpose, we suggest a new length and alignment control scheme, using coherent control sidebands which are already used to control the squeezing angle. Since both squeezed vacuum states and coherent control sidebands have the same mode matching conditions and almost the same frequency, detuning and alignment of the filter cavity can be controlled accurately with this scheme. In this paper, we show the principle of this scheme and its application to a gravitational-wave detector.

physics.ins-det

Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA

Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.

gr-qc

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM

Estimation of losses in a 300 m filter cavity and quantum noise reduction in the KAGRA gravitational-wave detector

The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection of squeezed states of light, where the squeezing angle is dynamically rotated by a Fabry-Pérot filter cavity. One of the main issues in the filter cavity design and realization is the optical losses due to the mirror surface imperfections. In this work we present a study of the specifications for the mirrors to be used in a 300 m filter cavity for the KAGRA detector. A prototype of the cavity will be constructed at the National Astronomical Observatory of Japan, inside the infrastructure of the former TAMA interferometer. We also discuss the potential improvement of the KAGRA sensitivity, based on a model of various realistic sources of losses and their influence on the squeezing amplitude.

astro-ph.IM

Prospects for improving the sensitivity of KAGRA gravitational wave detector

KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.

gr-qc

Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors

Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multi-wavelength technique, the round trip losses have been measured to be between 50 ppm and 90 ppm. This result demonstrates that with realistic assumption on the input squeeze factor and on the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.

astro-ph.IM