SearcharxivSearch

arXiv subjects

Eleonora Polini

Publications and source records attributed to Eleonora Polini.

7 recordsLinked to original sources

Demonstration of length control for a filter cavity with coherent control sidebands

For broadband quantum noise reduction of gravitational-wave detectors, a frequency-dependent squeezed vacuum field realized using a filter cavity is the most promising technique and will be implemented in Advanced LIGO and Advanced Virgo in the fourth observing run. To obtain the benefit of frequency-dependent squeezing, the length and alignment of the filter cavity with respect to the squeezed vacuum field must be accurately controlled. To this purpose, a new length and alignment control scheme for a filter cavity, using coherent control sidebands, was suggested [Phys. Rev. D 102, 042003 (2020)]. The coherent control sidebands are already used to control the squeezing angle in squeezed vacuum sources for gravitational-wave detectors. As both the squeezed vacuum field and coherent control sidebands have the same mode-matching conditions and almost the same frequency, the length and alignment of the filter cavity with respect to the squeezed vacuum field can be accurately controlled with this scheme. In this paper, we experimentally demonstrate the new control scheme for a filter cavity with coherent control sidebands. In addition to the conventional filter cavity control with the green field, we succeed in controlling the length of a 300-m filter cavity with coherent control sidebands and reduce the filter cavity length noise (rms) from 6.8 to 2.1 pm.

physics.ins-det

NovaMoon: A Strategic Lunar Reference Station for Positioning, Timing, and Largely Enhanced Science in the Earth-Moon System

The renewed interest in lunar exploration and the development of future lunar communication and navigation services highlight the need for a precise, stable, and interoperable geodetic and timing infrastructure on the Moon. NovaMoon, proposed as a scientific and navigation payload for ESA's Argonaut lander, is designed as a lunar-based local differential, geodetic, and timing station supporting both operational needs in the Moon's south polar region and a broad range of scientific investigations. The payload integrates a lunar laser retroreflector, a Very Long Baseline Interferometry transmitter, a receiver for navigation signals compatible with LunaNet standards, high-stability atomic clocks, and direct-to-Earth radio links -- making it the first lunar station to co-locate multiple ranging, tracking, and timing techniques. NovaMoon will enable sub-metre to decimetre positioning, provide local differential corrections for lunar users, and ensure an accurate and stable realisation of position and time. Preliminary simulation studies show that this multi-technique dataset improves the lunar reference frame, orientation and ephemerides, and estimates of interior parameters like tidal response and core properties. NovaMoon will also provide the first long-duration physical realisation of a lunar time reference. Beyond its primary goals, it supports improved cartography, precise surface geolocation, and higher-resolution topography, contributing to safer landings and operations. It also enables new tests of fundamental physics, including constraints on relativity and possible deviations from classical gravity.

astro-ph.EP

50-km fiber interferometer for testing gravitational signatures in quantum interference

Quantum mechanics and general relativity are the foundational pillars of modern physics, yet experimental tests that combine the two frameworks remain rare. Measuring optical phase shifts of massless photons in a gravitational potential provides a unique quantum platform to probe gravity beyond Newtonian descriptions, but laboratory-based interferometers have not yet reached the sensitivity needed to access this regime. Here, we report the realization of a 50-km table-top Mach-Zehnder fiber interferometer operating at the single-photon level, achieving a phase sensitivity of $4.42\times10^{-6}$ rad root-mean-square (RMS) within the frequency range of 0.01 Hz to 5 Hz. We demonstrate that this sensitivity is sufficient to resolve a phase-shift signal of $(6.18 \pm 0.44)\times10^{-5}$ rad RMS at 0.1 Hz, associated with a modulated gravity-induced signal. Our results establish a milestone for quantum sensing with large-scale optical interferometry, demonstrating the capability to detect gravitational redshifts in a local laboratory, thereby paving the way for testing quantum phenomena within general relativistic frameworks.

quant-ph

High-Sensitivity Fiber Interferometer for Gravitational Phase Shift Measurement on Entangled States

In this contribution, we describe the status of our experiment aimed at measuring the gravitationally induced phase shift on path-entangled photons. We use a kilometer-scale fiber interferometer whose arms are vertically displaced in the Earth gravitational potential, allowing photons propagating at different heights to accumulate different phases. To date, this is the first experiment to measure this effect on massless particles, thereby experimentally combining general relativity and quantum mechanics.

quant-ph

A high angular resolution interferometric backscatter meter

Backscatter limits many interferometric measurements, including gravitational wave detectors, by creating spurious interference. We describe an experimental method to directly and quantitatively measure the backscatter interference. We derive and verify experimentally a relation between backscatter interference, beam radius and the scattering sample bidirectional reflectance distribution function. We also demonstrate that our method is able to measure backscatter from high quality optics for angles as low as 500 urad with a 160 urad angular resolution.

physics.optics

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

physics.ins-det

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

astro-ph.IM