SearcharxivSearch

arXiv subjects

Elisabeth Renner

Publications and source records attributed to Elisabeth Renner.

3 recordsLinked to original sources

Noninvasive ion fraction quantification of dual-species beams in synchrotrons

The ion composition of dual-species beams in synchrotrons is typically inferred from invasive measurements performed after beam extraction. This paper introduces a complementary noninvasive method to determine the ion composition of such beams directly inside the synchrotron. The approach is applicable to low- and medium-energy synchrotrons and to small relative mass-to-charge ratio offsets, typically at the 1e-4 level. The method exploits dispersive orbit offsets between the two species and corresponding frequency corrections applied by the synchrotron RF radial regulation loop. This capability is of particular interest for ongoing research on online monitoring in carbon ion beam therapy using mixed 4He2+ and 12C6+ beams, which feature a relative mass-to-charge ratio offset of 0.065%. The proposed method is analytically derived and tested with particle tracking simulations using Xsuite. Its applicability under realistic experimental conditions is demonstrated at the MedAustron facility using mixed 4He2+ and 12C6+ beams. The results show good agreement with independent post-extraction measurements.

physics.acc-ph

A double multi-turn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities

The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately three times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently "mixing" them at injection energy in the synchrotron with a double multi-turn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multi-turn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multi-turn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode (LGAD) detector are presented.

physics.acc-ph

Pulsed RF Knock-Out Extraction: A Potential Enabler for FLASH Hadrontherapy in the Bragg Peak

One challenge on the path to delivering FLASH-compatible beams with a synchrotron is facilitating an accurate dose-control for the required ultra-high dose rates. We propose the use of pulsed RFKO extraction instead of continuous beam delivery as a way to control the dose delivered per Voxel. In a first feasibility test dose rates in pulses of up to 600 Gy/s were observed, while the granularity at which the dose was delivered is expected to be well below 0.5 Gy.

physics.med-ph