Searcharxiv⌕ Search

arXiv subjects

Elliot R. McVeigh

Publications and source records attributed to Elliot R. McVeigh.

3 recordsLinked to original sources

Temporal Training Strategies for Left Atrium and Left Atrial Appendage Segmentation in Dynamic Contrast 4DCT

Dynamic contrast-enhanced cardiac CT enables time-resolved analysis of contrast filling and washout in the left atrium (LA) and left atrial appendage (LAA), with potential applications for assessing blood stasis in atrial fibrillation (AF). Accurate segmentation across all frames is required for such analysis but is challenging due to large temporal contrast variations and the use of a single annotation per registered sequence. This creates a trade-off between training for robustness and limiting label noise. In this study, we investigate how temporal training-set design affects nnUNet-based segmentation of the LA and LAA in dynamic 4DCT. We compare training using a minimal two-frame dataset reflecting standard clinical practice, a physiologically selected subset of frames, and the full 27-frame sequence. We further evaluate the impact of foreground-based normalization. Training with all frames yielded the best performance in early low-contrast phases. However, the physiologically selected subset achieved comparable performance from the filling phase onward. Applying normalization parameters derived from the full dataset improved performance of reduced datasets in low-contrast frames, but did not fully close the gap. These findings highlight the importance of temporal diversity in training data for robust segmentation in dynamic CT, while indicating that carefully selected frame subsets may provide an effective trade-off between performance and efficiency for downstream applications.

cs.CV↗

Estimation of Blood Flow Parameters in the Left Atrial Appendage from 4DCT Dynamic Contrast Enhancement

Cardiac CT is often used clinically in electrophysiology to evaluate cardiac morphology. One such case is to evaluate patients with Atrial Fibrillation (AF). AF can cause regions of slow blood flow and blood stasis through the left atrial appendage (LAA), and therefore, it may be preferable to evaluate blood flow through the LAA in addition to morphology. Although CT cannot measure flow directly, CT data has been used to estimate flow using modeling approaches such as Computational Fluid Dynamics, which take into account the cardiac geometry to simulate flow. Advances in CT technology now enable high-resolution imaging of the whole heart with low radiation doses. With multi-heartbeat imaging during a contrast injection, we can obtain 4-dimentional CT (4DCT) images to measure dynamic contrast enhancement directly. In this study, we use high-resolution 4DCT to acquire images of contrast enhancement across the LAA over multiple heartbeats. The CT contrast signal at each voxel over time is used to create dynamic contrast enhancement maps of parameters derived from a gamma-variate fit. These contrast enhancement maps enable quantification and visualization of spatial-temporal characteristics of flow parameters across the LAA.

eess.IV↗

Protocol Optimization for Functional Cardiac CT Imaging Using Noise Emulation in the Raw Data Domain

Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across several heartbeats is still a concern. A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable. Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the low dose threshold, a projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector. Experiments were performed to validate the noise emulation method with both phantom and clinical data. For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude, artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. In conclusion, a detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

physics.med-ph↗