SearcharxivSearch

arXiv subjects

Elsa Fouragnan

Publications and source records attributed to Elsa Fouragnan.

2 recordsLinked to original sources

A Practical Guide to Transcranial Ultrasonic Stimulation from the IFCN-endorsed ITRUSST Consortium

Low-intensity Transcranial Ultrasonic Stimulation (TUS) is a non-invasive brain stimulation technique enabling cortical and deep brain targeting with unprecedented spatial accuracy. Given the high rate of adoption by new users with varying levels of expertise and interdisciplinary backgrounds, practical guidelines are needed to ensure state-of-the-art TUS application and reproducible outcomes. Therefore, the International Transcranial Ultrasonic Stimulation Safety and Standards (ITRUSST) consortium has formed a subcommittee, endorsed by the International Federation of Clinical Neurophysiology (IFCN), to develop recommendations for best practice in TUS applications in humans. The practical guide presented here provides a brief introduction into ultrasound physics and sonication parameters. It explains the requirements of TUS lab equipment and transducer selection and discusses experimental design and procedures alongside potential confounds and control conditions. Finally, the guide elaborates on essential steps of application planning for stimulation safety and efficacy, as well as considerations when combining TUS with neuroimaging, electrophysiology, or other brain stimulation techniques. We hope that this practical guide to TUS will assist both novice and experienced users in planning and conducting high-quality studies and provide a solid foundation for further advancements in this promising field.

physics.med-ph

ITRUSST Consensus on Biophysical Safety for Transcranial Ultrasound Stimulation

Transcranial ultrasound stimulation (TUS) is an emerging technology for non-invasive brain stimulation. The International Transcranial Ultrasonic Stimulation Safety and Standards consortium (ITRUSST) has established consensus on considerations for nonsignificant biophysical risk of TUS, drawing upon the literature and established regulations for biomedical devices. Here, we assume the application of TUS to individuals without contraindications, compromised thermoregulation, vascular vulnerabilities, or administered ultrasound contrast agents. In this context, we present a concise yet comprehensive set of levels for nonsignificant risks of TUS application. For mechanical effects, it is non-significant risk if the mechanical index (MI) or the mechanical index for transcranial application (MItc) does not exceed 1.9. For thermal effects, it is non-significant risk if any of the following three levels are met: the peak temperature rise does not exceed 2{\deg}C or the peak absolute temperature does not exceed 39{\deg}C, assuming a baseline temperature of 37{\deg}C, the thermal dose does not exceed 2 CEM43 in brain tissue, 16 CEM43 in bone tissue, and 21 CEM43 in skin tissue, or specific values of the thermal index (TI) for a given exposure time. This report reflects a consensus expert opinion and can inform, but not replace, regulatory guidelines or official international standards. Similarly, this consensus can inform, but not replace, ethical evaluation, which weighs the total burden, risks, and benefits of the proposed action. The stated levels are not safety limits per se, and further data is needed to establish the threshold for significant risk. We review literature relevant to our considerations and discuss limitations and future developments of our approach.

physics.bio-ph