SearcharxivSearch

arXiv subjects

Emanuele Perinati

Publications and source records attributed to Emanuele Perinati.

7 recordsLinked to original sources

High-statistics simulations of NewAthena WFI background using Geant4

The observation of hot gas structures is one science goal of the Wide Field Imager (WFI) on ESA's NewAthena X-ray observatory. Because the measurement of these faint diffuse sources is limited by background from cosmic ray particle interactions within the instrument, understanding and reducing this background is critical. To this end, we employ a two-pronged approach, performing high-fidelity Geant4 simulations on both detailed, realistic geometry models as well as complementary simple geometry models. The former can reveal subtle sensitivities of background to details of the instrument design. The latter allows for fast iteration, useful in guiding and understanding the larger simulations. We show how we leverage High Performance Computing (HPC) resources to achieve simultaneously high throughput and fast time to result. We discuss our recent results, which are applicable not only to WFI, but also other X-ray missions.

astro-ph.IM

Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors

The level and uncertainty of the particle induced background in CCD detectors plays a crucial role for future X-ray instruments, such as the Wide Field Imager (WFI) onboard Athena. To mitigate the background systematic uncertainties, which will limit the Athena science goals, we aim to understand the relationship between the energetic charged particles interacting in the detector and satellite, and the instrumental science background to an unprecedented level. These particles produce easily identified "cosmic-ray tracks" along with less easily identified signals produced by secondary particles, e.g., X-rays generated by particle interactions with the instrument and indistinguishable from genuine sky X-rays. We utilize the Small Window Mode of the PN camera onboard XMM-Newton to understand the time, spatial and energy dependence of the various background components, particularly the particle induced background. While the distribution of particle events follows expected detector readout patterns, we find a particle track length distribution inconsistent with the simple, isotropic model. We also find that the detector mode-specific readout results in a shifted Cu fluorescent line. We illustrate that on long timescales the variability of the particle background correlates well with the solar cycle. This 20-year lightcurve, can be reproduced by a particle detector onboard Chandra, the HRC anti-coincidence shield. We conclude that the self-anti-coincidence method of removing X-ray-like events near detected particle tracks in the same frame can be optimized with the inclusion of additional information, such as the energy of the X-ray. The results presented here are relevant for any future pixelated X-ray imaging detector, and could allow the WFI to probe to truly faint X-ray surface brightness.

astro-ph.IM

Geant4 simulation of the residual background in the ATHENA Wide Field Imager from protons deflected by the Charged Particle Diverter

X-ray telescopes opened up a new window into the high-energy universe. However, the last generation of these telescopes encountered an unexpected problem: their optics focused not only X-rays but low-energy (so called soft) protons as well. These protons are very hard to model and can not be distinguished from X-rays. For example, 40\% of XMM-Newton observations is significantly contaminated by soft proton induced background flares. In order to minimize the background from such low-energy protons the Advanced Telescope for High ENergy Astrophysics (ATHENA) satellite introduced a novel concept, the so called Charged Particle Diverter (CPD). It is an array of magnets in a Hallbach design, which deflects protons below 76 keV before they would hit the Wide Field Imager (WFI) detector. In this work, we investigate the effect of scattering of the deflected protons with the CPD walls and the inner surfaces of the WFI detector assembly. Such scattered protons can loose energy, change direction and still hit the WFI. In order to adopt the most realistic instrument model, we imported the CAD model of both the CPD and the WFI focal plane assembly. Soft protons corresponding to $\approx$2.5 hours of exposure to the L1 solar wind are simulated in this work. The inhomogeneous magnetic field of the CPD is included in the simulation. We present a preliminary estimate of the WFI residual background induced by soft proton secondary scattering, in the case of the optical blocking filter present in the field of view. A first investigation of the volumes responsible for scattering the protons back into the field of view is reported.

astro-ph.IM

Athena charged particle diverter simulations: effects of micro-roughness on proton scattering using Geant4

The last generation of X-ray focusing telescopes operating outside the Earth's radiation belt discovered that optics were able to focus not only astrophysical X-ray photons, but also low-energy heliophysical protons entering the Field of View (FOV). This "soft proton" contamination affects around 40\% of the observation time of XMM-Newton. The ATHENA Charged Particle Diverter (CPD) was designed to use magnetic fields to move these soft protons away from the FOV of the detectors, separating the background-contributing ions in the focused beam from the photons of interest. These magnetically deflected protons can hit other parts of the payload and scatter back to the focal plane instruments. Evaluating the impact of this secondary scattering with accurate simulations is essential for the CPD scientific assessment. However, while Geant4 simulations of grazing soft proton scattering on X-ray mirrors have been recently validated, the scattering on the unpolished surfaces of the payload (e.g. the baffle or the diverter itself) is still to be verified with experimental results. Moreover, the roughness structure can affect the energy and angle of the scattered protons, with a scattering efficiency depending on the specific target volume. Using Atomic Force Microscopy to take nanometer-scale surface roughness measurements from different materials and coating samples, we use Geant4 together with the CADMesh library to shoot protons at these very detailed surface roughness models to understand the effects of different material surface roughnesses, coatings, and compositions on proton energy deposition and scattering angles. We compare and validate the simulation results with laboratory experiments, and propose a framework for future proton scattering experiments.

astro-ph.IM

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

astro-ph.IM

The Large Area Detector onboard the eXTP mission

The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.

astro-ph.IM

A setup for soft proton irradiation of X-ray detectors for future astronomical space missions

Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, impinging on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detectors with soft protons has been constructed at the Van-de-Graaff accelerator of the Physikalisches Institut of the University of Tübingen. Key advantages are a high flux uniformity over a large area, to enable irradiations of large detectors, and a monitoring system for the applied fluence, the beam uniformity, and the spectrum, that allows testing of detector prototypes in early development phases, when readout electronics are not yet available. Two irradiation campaigns have been performed so far with this setup. The irradiated detectors are silicon drift detectors, designated for the use on-board the LOFT space mission. This paper gives a description of the experimental setup and the associated monitoring system.

astro-ph.IM