SearcharxivSearch

arXiv subjects

Emiliano Votta

Publications and source records attributed to Emiliano Votta.

9 recordsLinked to original sources

Evaluation of Augmented Reality-based Intuitive Interface for Robot-Assisted Transesophageal Echocardiography: A User Study

TransEsophageal Echocardiography (TEE) is essential for diagnosing and guiding Structural Heart Disease (SHD) interventions. However, manual TEE manipulation demands significant operator expertise, is physically demanding, and exposes clinicians to radiation when performed alongside fluoroscopy. Robotic-assisted TEE systems have been introduced to improve probe handling and reduce operator fatigue, yet the design of intuitive and effective user interfaces remains an open challenge. This study presents and evaluates a model-enhanced, Augmented Reality (AR)-based intuitive interface for robot-assisted TEE, designed to improve spatial awareness and control intuitiveness. A robotic TEE platform integrated with electromagnetic tracking and a virtual simulator was used to compare three user interfaces differing in visualization and interaction modalities: 2D jointlevel (2D-JI), 3D joint-level (3D-JI), and 3D tip-level (3D-TI). Thirty six participants performed standardized navigation tasks to reproduce target echocardiographic views, with performance assessed via position and orientation errors, completion time, and NASA-TLX workload scores. Results show that 3D visualization significantly improved spatial accuracy, reducing median position error from 13 mm to 3 mm and halving the orientation error compared with the 2D interface. Tip-level interaction yielded a further 50% reduction in orientation error and reduced interuser variability relative to joint-level control. Overall, the 3D-TI configuration, combining immersive visualization with direct tip-level control, proved the most effective and ergonomic interface, supporting the integration of AR-based visualization and intuitive control paradigms into next-generation robotic TEE systems to enhance operator performance and procedural safety.

cs.RO

Catheter Monitoring in Intelligent Endovascular Navigation Systems: Interactive Simulations and Mixed Reality for Enhanced Navigational Awareness

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter-vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was tested in-vitro using a sensorized catheter with Fiber Bragg Grating and electromagnetic sensors as it was advanced through a silicone replica of the vascular anatomy. Real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens 2. The performance and accuracy of FEM-computed vessel wall displacement were validated against experimental ground-truth obtained via stereo frames triangulation. Results: The simulated time exceeded the real temporal extent by 12% during initial navigation and by 45% when the catheter reached the most tortuous portion. Hololens 2 rendering remained stable at 35-40 frames per second. The median relative displacement error between FEM-computed and ground-truth vessel wall displacements remained below 1 mm and 2.33 mm for these two phases, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter-vessel interactions, with mixed reality visualization serving as a user interface to support operator decision-making.

cs.HC

Physics-driven Sonification for Improving Multisensory Needle Guidance in Percutaneous Epicardial Access

Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin and moving pericardium remains highly challenging and risky. To address this problem, we present a physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception during the critical needle landing phase in PEA. Dynamic cardiac anatomy from 4D CTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided the position of the needle tip relative to moving cardiac structures and drove an audio-visual feedback module. The visual display presented navigational cues and dynamic anatomy, while the auditory display encoded physiological cardiac states using a multilayer physical membrane model. A phantom study was conducted with twelve cardiologists performing needle insertions under visual-only and multisensory feedback. The multisensory method significantly improved navigation safety ($χ^2 = 11.30$, $p < 0.01$), reducing myocardial contact (3.64% vs. 7.27%) and increasing correct access (90.91% vs. 52.73%). Needle placement accuracy improved, with closer membrane proximity (Cliff delta = 0.19) and reduced variability ($p < 0.05$). Execution time was comparable, while time-accuracy correlations differed significantly between modalities ($p < 0.01$). NASA-TLX indicated lower cognitive load with multisensory guidance ($p < 0.01$). These results demonstrate the feasibility of physics-driven sonification for improving spatiotemporal awareness and supporting user-centered surgical navigation.

cs.HC

BioSonix: Can Physics-Based Sonification Perceptualize Tissue Deformations From Tool Interactions?

Perceptualizing tool interactions with deformable structures in surgical procedures remains challenging, as unimodal visualization techniques often fail to capture the complexity of these interactions due to constraints such as occlusion and limited depth perception. This paper presents a novel approach to augment tool navigation in mixed reality environments by providing auditory representations of tool-tissue dynamics, particularly for interactions with soft tissue. BioSonix, a physics-informed design framework, utilizes tissue displacements in 3D space to compute excitation forces for a sound model encoding tissue properties such as stiffness and density. Biomechanical simulations were employed to model particle displacements resulting from tool-tissue interactions, establishing a robust foundation for the method. An optimization approach was used to define configurations for capturing diverse interaction scenarios with varying tool trajectories. Experiments were conducted to validate the accuracy of the sound-displacement mappings. Additionally, two user studies were performed: the first involved two clinical professionals (a neuroradiologist and a cardiologist), who confirmed the method's impact and achieved high task accuracy; the second included 22 biomedical experts, who demonstrated high discrimination accuracy in tissue differentiation and targeting tasks. The results revealed a strong correlation between tool-tissue dynamics and their corresponding auditory profiles, highlighting the potential of these sound representations to enhance the intuitive understanding of complex interactions.

cs.SD

MitraClip Device Automated Localization in 3D Transesophageal Echocardiography via Deep Learning

The MitraClip is the most widely percutaneous treatment for mitral regurgitation, typically performed under the real-time guidance of 3D transesophagel echocardiography (TEE). However, artifacts and low image contrast in echocardiography hinder accurate clip visualization. This study presents an automated pipeline for clip detection from 3D TEE images. An Attention UNet was employed to segment the device, while a DenseNet classifier predicted its configuration among ten possible states, ranging from fully closed to fully open. Based on the predicted configuration, a template model derived from computer-aided design (CAD) was automatically registered to refine the segmentation and enable quantitative characterization of the device. The pipeline was trained and validated on 196 3D TEE images acquired using a heart simulator, with ground-truth annotations refined through CAD-based templates. The Attention UNet achieved an average surface distance of 0.76 mm and 95% Hausdorff distance of 2.44 mm for segmentation, while the DenseNet achieved an average weighted F1-score of 0.75 for classification. Post-refinement, segmentation accuracy improved, with average surface distance and 95% Hausdorff distance reduced to 0.75 mm and 2.05 mm, respectively. This pipeline enhanced clip visualization, providing fast and accurate detection with quantitative feedback, potentially improving procedural efficiency and reducing adverse outcomes.

q-bio.QM

A Deep Learning-Based Fully Automated Pipeline for Regurgitant Mitral Valve Anatomy Analysis From 3D Echocardiography

Three-dimensional transesophageal echocardiography (3DTEE) is the recommended imaging technique for the assessment of mitral valve (MV) morphology and lesions in case of mitral regurgitation (MR) requiring surgical or transcatheter repair. Such assessment is key to thorough intervention planning and to intraprocedural guidance. However, it requires segmentation from 3DTEE images, which is timeconsuming, operator-dependent, and often merely qualitative. In the present work, a novel workflow to quantify the patient-specific MV geometry from 3DTEE is proposed. The developed approach relies on a 3D multi-decoder residual convolutional neural network (CNN) with a U-Net architecture for multi-class segmentation of MV annulus and leaflets. The CNN was trained and tested on a dataset comprising 55 3DTEE examinations of MR-affected patients. After training, the CNN is embedded into a fully automatic, and hence fully repeatable, pipeline that refines the predicted segmentation, detects MV anatomical landmarks and quantifies MV morphology. The trained 3D CNN achieves an average Dice score of $0.82 \pm 0.06$, mean surface distance of $0.43 \pm 0.14$ mm and 95% Hausdorff Distance (HD) of $3.57 \pm 1.56$ mm before segmentation refinement, outperforming a state-of-the-art baseline residual U-Net architecture, and provides an unprecedented multi-class segmentation of the annulus, anterior and posterior leaflet. The automatic 3D linear morphological measurements of the annulus and leaflets, specifically diameters and lengths, exhibit differences of less than 1.45 mm when compared to ground truth values. These measurements also demonstrate strong overall agreement with analyses conducted by semi-automated commercial software. The whole process requires minimal user interaction and requires approximately 15 seconds

cs.CV

A CT-based deep learning system for automatic assessment of aortic root morphology for TAVI planning

Accurate planning of transcatheter aortic implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly done through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks (CNNs) with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performed AR segmentation and model 2 identified the aortic annulus and sinotubular junction (STJ) contours. Results were validated against manual measurements of 178 TAVI candidates. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. The trained CNNs effectively segmented the AR, annulus and STJ, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 1.16 mm and 1.30 mm for the annulus and STJ, respectively. Automatic measurements were in good agreement with manual annotations, yielding annulus diameters that differed by 0.52 [-2.96, 4.00] mm (bias and 95% limits of agreement for manual minus algorithm). Evaluating the area-derived diameter, bias and limits of agreement were 0.07 [-0.25, 0.39] mm. STJ and sinuses diameters computed by the automatic method yielded differences of 0.16 [-2.03, 2.34] and 0.1 [-2.93, 3.13] mm, respectively. The proposed tool is a fully automatic solution to quantify morphological biomarkers for pre-TAVI planning. The method was validated against manual annotation from clinical experts and showed to be quick and effective in assessing AR anatomy, with potential for time and cost savings.

q-bio.QM

Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta

Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoracic aortic aneurysms (ATAA). To accurately reproduce hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow boundary conditions (BCs). However, the limited availability of in vivo velocity measurements still makes researchers resort to idealized BCs. In this study we generated and thoroughly characterized a large dataset of synthetic 4D aortic velocity profiles suitable to be used as BCs for CFD simulations. 4D flow MRI scans of 30 subjects with ATAA were processed to extract cross-sectional planes along the ascending aorta, ensuring spatial alignment among all planes and interpolating all velocity fields to a reference configuration. Velocity profiles of the clinical cohort were extensively characterized by computing flow morphology descriptors of both spatial and temporal features. By exploiting principal component analysis (PCA), a statistical shape model (SSM) of 4D aortic velocity profiles was built and a dataset of 437 synthetic cases with realistic properties was generated. Comparison between clinical and synthetic datasets showed that the synthetic data presented similar characteristics as the clinical population in terms of key morphological parameters. The average velocity profile qualitatively resembled a parabolic-shaped profile, but was quantitatively characterized by more complex flow patterns which an idealized profile would not replicate. Statistically significant correlations were found between PCA principal modes of variation and flow descriptors. We built a data-driven generative model of 4D aortic velocity profiles, suitable to be used in computational studies of blood flow. The proposed software system also allows to map any of the generated velocity profiles to the inlet plane of any virtual subject given its coordinate set.

q-bio.TO

Simulation of left ventricle fluid dynamics with mitral regurgitation from magnetic resonance images with fictitious elastic structure regularization

Computer modeling can provide quantitative insight into cardiac fluid dynamics phenomena that are not evident from standard imaging tools. We propose a new approach to modeling left ventricle fluid dynamics based on an image-driven model-based description of ventricular motion. In this approach, the end-diastolic geometry and time-dependent deformation of the left ventricle cavity are obtained from cardiac magnetic resonance images and a fictitious elastic structure is used to impose the contractile behavior of the left ventricle. This allows seamless treatment of the isovolumic phases. Besides the ventricular motion, the intracavitary fluid dynamics is controlled by the mitral valve. Three different mitral valve models are included in the simulation: an idealized diode (with or without regurgitation) and a lumped parameter model accounting for the opening dynamics of the valve and including regurgitation.

physics.med-ph