Sub-Pixel Electron Beam Alignment for Machine Learning Characterization of Hybrid Pixel Detectors

Due to their radiation hardness, kilohertz frame rates, and high dynamic range, hybrid pixel detectors have recently expanded their application range to electron diffraction and recently also electron imaging. However, these detectors typically have pixel sizes about ten times larger than those of direct electron detectors commonly used for imaging and more prominent electron multiple scattering effects. To overcome these limitations, machine learning approaches can be utilized to reconstruct the electron entrance point and achieve super-resolution. As this process is inherently stochastic, and machine learning relies on suitable training data, high-quality, representative training data are essential for developing models that achieve the best possible resolution. In this work, we present two novel experimental methods for generating such training data. The first method employs precise microscope alignment to scan the detector plane using a finely focused electron beam of 2 μm diameter, enabling controlled sub-pixel mapping. The second method utilizes specially designed aperture masks with sub-pixel-sized holes to accurately localize electron entry points. We developed and validated two experimental strategies for collecting training data at acceleration voltages of 60, 80, 120, and 200 keV, which enable sub-pixel labeling for hybrid pixel detectors. Notably, our methodology is broadly applicable to a wide range of hybrid pixel detectors.

physics.ins-det

Calibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin

In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.

physics.ins-det