EchoLVFM: One-Step Video Generation via Latent Flow Matching for Echocardiogram Synthesis

Echocardiography is widely used for assessing cardiac function, where clinically meaningful parameters such as left-ventricular ejection fraction (EF) play a central role in diagnosis and management. Generative models capable of synthesising realistic echocardiogram videos with explicit control over such parameters are valuable for data augmentation, counterfactual analysis, and specialist training. However, existing approaches typically rely on computationally expensive multi-step sampling and aggressive temporal normalisation, limiting efficiency and applicability to heterogeneous real-world data. We introduce EchoLVFM, a one-step latent video flow-matching framework for controllable echocardiogram generation. Operating in the latent space, EchoLVFM synthesises temporally coherent videos in a single inference step, achieving a $\mathbf{\sim 50\times}$ improvement in sampling efficiency compared to multi-step flow baselines while maintaining visual fidelity. The model supports global conditioning on clinical variables, demonstrated through precise control of EF, and enables reconstruction and counterfactual generation from partially observed sequences. A masked conditioning strategy further removes fixed-length constraints, allowing shorter sequences to be retained rather than discarded. We evaluate EchoLVFM on the CAMUS dataset under challenging single-frame conditioning. Quantitative and qualitative results demonstrate competitive video quality, strong EF adherence, and 57.9% discrimination accuracy by expert clinicians which is close to chance. These findings indicate that efficient, one-step flow matching can enable practical, controllable echocardiogram video synthesis without sacrificing fidelity. Code available at: https://github.com/EngEmmanuel/EchoLVFM

eess.IV

From Transthoracic to Transesophageal: Cross-Modality Generation using LoRA Diffusion

Deep diffusion models excel at realistic image synthesis but demand large training sets-an obstacle in data-scarce domains like transesophageal echocardiography (TEE). While synthetic augmentation has boosted performance in transthoracic echo (TTE), TEE remains critically underrepresented, limiting the reach of deep learning in this high-impact modality. We address this gap by adapting a TTE-trained, mask-conditioned diffusion backbone to TEE with only a limited number of new cases and adapters as small as $10^5$ parameters. Our pipeline combines Low-Rank Adaptation with MaskR$^2$, a lightweight remapping layer that aligns novel mask formats with the pretrained model's conditioning channels. This design lets users adapt models to new datasets with a different set of anatomical structures to the base model's original set. Through a targeted adaptation strategy, we find that adapting only MLP layers suffices for high-fidelity TEE synthesis. Finally, mixing less than 200 real TEE frames with our synthetic echoes improves the dice score on a multiclass segmentation task, particularly boosting performance on underrepresented right-heart structures. Our results demonstrate that (1) semantically controlled TEE images can be generated with low overhead, (2) MaskR$^2$ effectively transforms unseen mask formats into compatible formats without damaging downstream task performance, and (3) our method generates images that are effective for improving performance on a downstream task of multiclass segmentation.

eess.IV

Transesophageal Echocardiography Generation using Anatomical Models

Through automation, deep learning (DL) can enhance the analysis of transesophageal echocardiography (TEE) images. However, DL methods require large amounts of high-quality data to produce accurate results, which is difficult to satisfy. Data augmentation is commonly used to tackle this issue. In this work, we develop a pipeline to generate synthetic TEE images and corresponding semantic labels. The proposed data generation pipeline expands on an existing pipeline that generates synthetic transthoracic echocardiography images by transforming slices from anatomical models into synthetic images. We also demonstrate that such images can improve DL network performance through a left-ventricle semantic segmentation task. For the pipeline's unpaired image-to-image (I2I) translation section, we explore two generative methods: CycleGAN and contrastive unpaired translation. Next, we evaluate the synthetic images quantitatively using the Fréchet Inception Distance (FID) Score and qualitatively through a human perception quiz involving expert cardiologists and the average researcher. In this study, we achieve a dice score improvement of up to 10% when we augment datasets with our synthetic images. Furthermore, we compare established methods of assessing unpaired I2I translation and observe a disagreement when evaluating the synthetic images. Finally, we see which metric better predicts the generated data's efficacy when used for data augmentation.