SearcharxivSearch

arXiv subjects

Emmanuel Vander Poorten

Publications and source records attributed to Emmanuel Vander Poorten.

14 recordsLinked to original sources

Catheter Monitoring in Intelligent Endovascular Navigation Systems: Interactive Simulations and Mixed Reality for Enhanced Navigational Awareness

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter-vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was tested in-vitro using a sensorized catheter with Fiber Bragg Grating and electromagnetic sensors as it was advanced through a silicone replica of the vascular anatomy. Real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens 2. The performance and accuracy of FEM-computed vessel wall displacement were validated against experimental ground-truth obtained via stereo frames triangulation. Results: The simulated time exceeded the real temporal extent by 12% during initial navigation and by 45% when the catheter reached the most tortuous portion. Hololens 2 rendering remained stable at 35-40 frames per second. The median relative displacement error between FEM-computed and ground-truth vessel wall displacements remained below 1 mm and 2.33 mm for these two phases, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter-vessel interactions, with mixed reality visualization serving as a user interface to support operator decision-making.

cs.HC

Localising under the drape: proprioception in the era of distributed surgical robotic system

Despite their mechanical sophistication, surgical robots remain blind to their surroundings. This lack of spatial awareness causes collisions, system recoveries, and workflow disruptions, issues that will intensify with the introduction of distributed robots with independent interacting arms. Existing tracking systems rely on bulky infrared cameras and reflective markers, providing only limited views of the surgical scene and adding hardware burden in crowded operating rooms. We present a marker-free proprioception method that enables precise localisation of surgical robots under their sterile draping despite associated obstruction of visual cues. Our method solely relies on lightweight stereo-RGB cameras and novel transformer-based deep learning models. It builds on the largest multi-centre spatial robotic surgery dataset to date (1.4M self-annotated images from human cadaveric and preclinical in vivo studies). By tracking the entire robot and surgical scene, rather than individual markers, our approach provides a holistic view robust to occlusions, supporting surgical scene understanding and context-aware control. We demonstrate an example of potential clinical benefits during in vivo breathing compensation with access to tissue dynamics, unobservable under state of the art tracking, and accurately locate in multi-robot systems for future intelligent interaction. In addition, and compared with existing systems, our method eliminates markers and improves tracking visibility by 25%. To our knowledge, this is the first demonstration of marker-free proprioception for fully draped surgical robots, reducing setup complexity, enhancing safety, and paving the way toward modular and autonomous robotic surgery.

cs.RO

Force-Displacement Profiling for Robot-Assisted Deployment of a Left Atrial Appendage Occluder Using FBG-EM Distal Sensing

Atrial fibrillation (AF) increases the risk of thromboembolic events due to impaired function of the left atrial appendage (LAA). Left atrial appendage closure (LAAC) is a minimally invasive intervention designed to reduce stroke risk by sealing the LAA with an expandable occluder device. Current deployment relies on manual catheter control and imaging modalities like fluoroscopy and transesophageal echocardiography, which carry limitations including radiation exposure and limited positioning precision. In this study, we leverage a previously developed force-sensing delivery sheath integrating fiber Bragg gratings (FBGs) at the interface between the catheter and the occluder. Combined with electromagnetic (EM) tracking, this setup enables real-time measurement of interaction forces and catheter tip position during robot-assisted LAAC deployment in an anatomical phantom. We present a novel force-displacement profiling method that characterizes occluder deployment dynamics and identifies key procedural steps without relying on ionizing radiation. The force profiles reveal low-magnitude interaction forces, suggesting minimal mechanical stress on the surrounding anatomy. This approach shows promise in providing clinicians with enhanced intraoperative feedback, improving deployment outcome. Future work will focus on automating deployment steps classification and validating the sensing strategy in dynamic, realistic environments.

cs.RO

Robust Path Planning via Learning from Demonstrations for Robotic Catheters in Deformable Environments

Objective: Navigation through tortuous and deformable vessels using catheters with limited steering capability underscores the need for reliable path planning. State-of-the-art path planners do not fully account for the deformable nature of the environment. Methods: This work proposes a robust path planner via a learning from demonstrations method, named Curriculum Generative Adversarial Imitation Learning (C-GAIL). This path planning framework takes into account the interaction between steerable catheters and vessel walls and the deformable property of vessels. Results: In-silico comparative experiments show that the proposed network achieves a 38% higher success rate in static environments and 17% higher in dynamic environments compared to a state-of-the-art approach based on GAIL. In-vitro validation experiments indicate that the path generated by the proposed C-GAIL path planner achieves a targeting error of 1.26$\pm$0.55mm and a tracking error of 5.18$\pm$3.48mm. These results represent improvements of 41% and 40% over the conventional centerline-following technique for targeting error and tracking error, respectively. Conclusion: The proposed C-GAIL path planner outperforms the state-of-the-art GAIL approach. The in-vitro validation experiments demonstrate that the path generated by the proposed C-GAIL path planner aligns better with the actual steering capability of the pneumatic artificial muscle-driven catheter utilized in this study. Therefore, the proposed approach can provide enhanced support to the user in navigating the catheter towards the target with greater accuracy, effectively meeting clinical accuracy requirements. Significance: The proposed path planning framework exhibits superior performance in managing uncertainty associated with vessel deformation, thereby resulting in lower tracking errors.

cs.RO

Vision and Contact based Optimal Control for Autonomous Trocar Docking

Future operating theatres will be equipped with robots to perform various surgical tasks including, for example, endoscope control. Human-in-the-loop supervisory control architectures where the surgeon selects from several autonomous sequences is already being successfully applied in preclinical tests. Inserting an endoscope into a trocar or introducer is a key step for every keyhole surgical procedure -- hereafter we will only refer to this device as a "trocar". Our goal is to develop a controller for autonomous trocar docking. Autonomous trocar docking is a version of the peg-in-hole problem. Extensive work in the robotics literature addresses this problem. The peg-in-hole problem has been widely studied in the context of assembly where, typically, the hole is considered static and rigid to interaction. In our case, however, the trocar is not fixed and responds to interaction. We consider a variety of surgical procedures where surgeons will utilize contact between the endoscope and trocar in order to complete the insertion successfully. To the best of our knowledge, we have not found literature that explores this particular generalization of the problem directly. Our primary contribution in this work is an optimal control formulation for automated trocar docking. We use a nonlinear optimization program to model the task, minimizing a cost function subject to constraints to find optimal joint configurations. The controller incorporates a geometric model for insertion and a force-feedback (FF) term to ensure patient safety by preventing excessive interaction forces with the trocar. Experiments, demonstrated on a real hardware lab setup, validate the approach. Our method successfully achieves trocar insertion on our real robot lab setup, and simulation trials demonstrate its ability to reduce interaction forces.

cs.RO

Filasofia: A Framework for Streamlined Development of Real-Time Surgical Simulations

Virtual reality simulation has become a popular approach for training and assessing medical students. It offers diverse scenarios, realistic visuals, and quantitative performance metrics for objective evaluation. However, creating these simulations can be time-consuming and complex, even for experienced users. The SOFA framework is an open-source solution that efficiently simulates finite element (FE) models in real-time. Yet, some users find it challenging to navigate the software due to the numerous components required for a basic simulation and their variability. Additionally, SOFA has limited visual rendering capabilities, leading developers to integrate other software for high-quality visuals. To address these issues, we developed Filasofia, a dedicated framework that simplifies development, provides modern visualization, and allows fine-tuning using SOFA objects. Our experiments demonstrate that Filasofia outperforms conventional SOFA simulations, even with real-time subdivision. Our design approach aims to streamline development while offering flexibility for fine-tuning. Future work will focus on further simplification of the development process for users.

cs.SE

Autonomous Navigation for Robot-assisted Intraluminal and Endovascular Procedures: A Systematic Review

Increased demand for less invasive procedures has accelerated the adoption of Intraluminal Procedures (IP) and Endovascular Interventions (EI) performed through body lumens and vessels. As navigation through lumens and vessels is quite complex, interest grows to establish autonomous navigation techniques for IP and EI for reaching the target area. Current research efforts are directed toward increasing the Level of Autonomy (LoA) during the navigation phase. One key ingredient for autonomous navigation is Motion Planning (MP) techniques. This paper provides an overview of MP techniques categorizing them based on LoA. Our analysis investigates advances for the different clinical scenarios. Through a systematic literature analysis using the PRISMA method, the study summarizes relevant works and investigates the clinical aim, LoA, adopted MP techniques, and validation types. We identify the limitations of the corresponding MP methods and provide directions to improve the robustness of the algorithms in dynamic intraluminal environments. MP for IP and EI can be classified into four subgroups: node, sampling, optimization, and learning-based techniques, with a notable rise in learning-based approaches in recent years. One of the review's contributions is the identification of the limiting factors in IP and EI robotic systems hindering higher levels of autonomous navigation. In the future, navigation is bound to become more autonomous, placing the clinician in a supervisory position to improve control precision and reduce workload.

cs.RO

RL-Based Guidance in Outpatient Hysteroscopy Training: A Feasibility Study

This work presents an RL-based agent for outpatient hysteroscopy training. Hysteroscopy is a gynecological procedure for examination of the uterine cavity. Recent advancements enabled performing this type of intervention in the outpatient setup without anaesthesia. While being beneficial to the patient, this approach introduces new challenges for clinicians, who should take additional measures to maintain the level of patient comfort and prevent tissue damage. Our prior work has presented a platform for hysteroscopic training with the focus on the passage of the cervical canal. With this work, we aim to extend the functionality of the platform by designing a subsystem that autonomously performs the task of the passage of the cervical canal. This feature can later be used as a virtual instructor to provide educational cues for trainees and assess their performance. The developed algorithm is based on the soft actor critic approach to smooth the learning curve of the agent and ensure uniform exploration of the workspace. The designed algorithm was tested against the performance of five clinicians. Overall, the algorithm demonstrated high efficiency and reliability, succeeding in 98% of trials and outperforming the expert group in three out of four measured metrics.

cs.AI

Robotic Endoscope Control via Autonomous Instrument Tracking

Many keyhole interventions rely on bi-manual handling of surgical instruments, forcing the main surgeon to rely on a second surgeon to act as a camera assistant. In addition to the burden of excessively involving surgical staff, this may lead to reduced image stability, increased task completion time and sometimes errors due to the monotony of the task. Robotic endoscope holders, controlled by a set of basic instructions, have been proposed as an alternative, but their unnatural handling may increase the cognitive load of the (solo) surgeon, which hinders their clinical acceptance. More seamless integration in the surgical workflow would be achieved if robotic endoscope holders collaborated with the operating surgeon via semantically rich instructions that closely resemble instructions that would otherwise be issued to a human camera assistant, such as "focus on my right-hand instrument". As a proof of concept, this paper presents a novel system that paves the way towards a synergistic interaction between surgeons and robotic endoscope holders. The proposed platform allows the surgeon to perform a bimanual coordination and navigation task, while a robotic arm autonomously performs the endoscope positioning tasks. Within our system, we propose a novel tooltip localization method based on surgical tool segmentation and a novel visual servoing approach that ensures smooth and appropriate motion of the endoscope camera. We validate our vision pipeline and run a user study of this system. The clinical relevance of the study is ensured through the use of a laparoscopic exercise validated by the European Academy of Gynaecological Surgery which involves bi-manual coordination and navigation. Successful application of our proposed system provides a promising starting point towards broader clinical adoption of robotic endoscope holders.

cs.RO

Real-Time Segmentation of Non-Rigid Surgical Tools based on Deep Learning and Tracking

Real-time tool segmentation is an essential component in computer-assisted surgical systems. We propose a novel real-time automatic method based on Fully Convolutional Networks (FCN) and optical flow tracking. Our method exploits the ability of deep neural networks to produce accurate segmentations of highly deformable parts along with the high speed of optical flow. Furthermore, the pre-trained FCN can be fine-tuned on a small amount of medical images without the need to hand-craft features. We validated our method using existing and new benchmark datasets, covering both ex vivo and in vivo real clinical cases where different surgical instruments are employed. Two versions of the method are presented, non-real-time and real-time. The former, using only deep learning, achieves a balanced accuracy of 89.6% on a real clinical dataset, outperforming the (non-real-time) state of the art by 3.8% points. The latter, a combination of deep learning with optical flow tracking, yields an average balanced accuracy of 78.2% across all the validated datasets.

cs.CV

Deep Placental Vessel Segmentation for Fetoscopic Mosaicking

During fetoscopic laser photocoagulation, a treatment for twin-to-twin transfusion syndrome (TTTS), the clinician first identifies abnormal placental vascular connections and laser ablates them to regulate blood flow in both fetuses. The procedure is challenging due to the mobility of the environment, poor visibility in amniotic fluid, occasional bleeding, and limitations in the fetoscopic field-of-view and image quality. Ideally, anastomotic placental vessels would be automatically identified, segmented and registered to create expanded vessel maps to guide laser ablation, however, such methods have yet to be clinically adopted. We propose a solution utilising the U-Net architecture for performing placental vessel segmentation in fetoscopic videos. The obtained vessel probability maps provide sufficient cues for mosaicking alignment by registering consecutive vessel maps using the direct intensity-based technique. Experiments on 6 different in vivo fetoscopic videos demonstrate that the vessel intensity-based registration outperformed image intensity-based registration approaches showing better robustness in qualitative and quantitative comparison. We additionally reduce drift accumulation to negligible even for sequences with up to 400 frames and we incorporate a scheme for quantifying drift error in the absence of the ground-truth. Our paper provides a benchmark for fetoscopy placental vessel segmentation and registration by contributing the first in vivo vessel segmentation and fetoscopic videos dataset.

cs.CV

Deep Sequential Mosaicking of Fetoscopic Videos

Twin-to-twin transfusion syndrome treatment requires fetoscopic laser photocoagulation of placental vascular anastomoses to regulate blood flow to both fetuses. Limited field-of-view (FoV) and low visual quality during fetoscopy make it challenging to identify all vascular connections. Mosaicking can align multiple overlapping images to generate an image with increased FoV, however, existing techniques apply poorly to fetoscopy due to the low visual quality, texture paucity, and hence fail in longer sequences due to the drift accumulated over time. Deep learning techniques can facilitate in overcoming these challenges. Therefore, we present a new generalized Deep Sequential Mosaicking (DSM) framework for fetoscopic videos captured from different settings such as simulation, phantom, and real environments. DSM extends an existing deep image-based homography model to sequential data by proposing controlled data augmentation and outlier rejection methods. Unlike existing methods, DSM can handle visual variations due to specular highlights and reflection across adjacent frames, hence reducing the accumulated drift. We perform experimental validation and comparison using 5 diverse fetoscopic videos to demonstrate the robustness of our framework.

eess.IV

Automatic Tool Landmark Detection for Stereo Vision in Robot-Assisted Retinal Surgery

Computer vision and robotics are being increasingly applied in medical interventions. Especially in interventions where extreme precision is required they could make a difference. One such application is robot-assisted retinal microsurgery. In recent works, such interventions are conducted under a stereo-microscope, and with a robot-controlled surgical tool. The complementarity of computer vision and robotics has however not yet been fully exploited. In order to improve the robot control we are interested in 3D reconstruction of the anatomy and in automatic tool localization using a stereo microscope. In this paper, we solve this problem for the first time using a single pipeline, starting from uncalibrated cameras to reach metric 3D reconstruction and registration, in retinal microsurgery. The key ingredients of our method are: (a) surgical tool landmark detection, and (b) 3D reconstruction with the stereo microscope, using the detected landmarks. To address the former, we propose a novel deep learning method that detects and recognizes keypoints in high definition images at higher than real-time speed. We use the detected 2D keypoints along with their corresponding 3D coordinates obtained from the robot sensors to calibrate the stereo microscope using an affine projection model. We design an online 3D reconstruction pipeline that makes use of smoothness constraints and performs robot-to-camera registration. The entire pipeline is extensively validated on open-sky porcine eye sequences. Quantitative and qualitative results are presented for all steps.

cs.CV

ToolNet: Holistically-Nested Real-Time Segmentation of Robotic Surgical Tools

Real-time tool segmentation from endoscopic videos is an essential part of many computer-assisted robotic surgical systems and of critical importance in robotic surgical data science. We propose two novel deep learning architectures for automatic segmentation of non-rigid surgical instruments. Both methods take advantage of automated deep-learning-based multi-scale feature extraction while trying to maintain an accurate segmentation quality at all resolutions. The two proposed methods encode the multi-scale constraint inside the network architecture. The first proposed architecture enforces it by cascaded aggregation of predictions and the second proposed network does it by means of a holistically-nested architecture where the loss at each scale is taken into account for the optimization process. As the proposed methods are for real-time semantic labeling, both present a reduced number of parameters. We propose the use of parametric rectified linear units for semantic labeling in these small architectures to increase the regularization ability of the design and maintain the segmentation accuracy without overfitting the training sets. We compare the proposed architectures against state-of-the-art fully convolutional networks. We validate our methods using existing benchmark datasets, including ex vivo cases with phantom tissue and different robotic surgical instruments present in the scene. Our results show a statistically significant improved Dice Similarity Coefficient over previous instrument segmentation methods. We analyze our design choices and discuss the key drivers for improving accuracy.

cs.CV