SearcharxivSearch

arXiv subjects

Enrico Verroi

Publications and source records attributed to Enrico Verroi.

7 recordsLinked to original sources

Observations of Low-Energy-Electron Production and Experimental Characterization of the Test-Mass Charging Process in the LISA Gravitational Reference Sensor with the BART Experiment

The Laser Interferometer Space Antenna (LISA) is a space-based gravitational-wave observatory that uses free-falling test masses as inertial references to detect milliHertz frequency signals. Interactions between test masses and galactic or solar energetic particles cause charge buildup and Coulomb forces, source of acceleration noise that must be accurately modeled. LISA Pathfinder measurements showed that the Poissonian test mass charging noise was considerably larger than that in pre launch simulations, indicating missing physical processes in early models. Emission of low energy secondary electrons (LEE) from test mass and housing surfaces has been proposed as a key mechanism affecting charging and the sensor electrostatic response. We report a particle accelerator based experiment that directly tests the LEE hypothesis by measuring proton induced test mass charging in a LISA like Gravitational Reference Sensor geometry as a function of the test mass electrostatic potential.

hep-ex

Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup

Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications in cancer therapy. For particle physics experiments requiring a single-particle resolution, pileup can significantly degrade data quality, making precise knowledge of the beam time structure essential for selecting appropriate readout parameters. However, such information is often unavailable from the facilities and challenging to determine experimentally. Here, we report measurements of the spill time structure at two medical accelerator facilities using a silicon carbide (SiC) particle sensor coupled to a high-frequency readout system. Owing to its high carrier saturation velocity and the tolerance to large bias voltages, SiC is well suited for fast readout and measurements requiring precise timing. Using a 6 GHz readout with custom SiC diodes, we characterize the micro-spill structure of both cyclotron and synchrotron beams on a sub-nanosecond timescale. The measured arrival-time distributions exhibit modulation with the accelerator RF frequencies, reflecting features of the extraction process. The resolved micro-spill structure enables quantitative estimation of pileup contributions and provides design constraints for future readout electronics. The presented results emphasize the importance of the characterization of the beam time-structure characterization for the development of precise readout systems.

physics.ins-det

Space applications of GAGG:Ce scintillators: a study of afterglow emission by proton irradiation

We discuss the results of a proton irradiation campaign of a GAGG:Ce (Cerium-doped Gadolinium Aluminium Gallium Garnet) scintillation crystal, carried out in the framework of the HERMES-TP/SP (High Energy Rapid Modular Ensemble of Satellites -- Technological and Scientific Pathfinder) mission. A scintillator sample was irradiated with 70 MeV protons, at levels equivalent to those expected in equatorial and sun-synchronous low-Earth orbits over orbital periods spanning 6 months to 10 years. The data we acquired are used to introduce an original model of GAGG:Ce afterglow emission. Results from this model are applied to the HERMES-TP/SP scenario, aiming at an upper-bound estimate of the detector performance degradation resulting from afterglow emission.

astro-ph.IM

New technique for determining a pulsar period: Waterfall principal component analysis

This paper describes a new technique for determining the optimal period of a pulsar and consequently its light curve. The implemented technique makes use of the Principal Component Analysis (PCA) applied to the so-called waterfall diagram, which is a bidimensional representation of the pulsar acquired data. In this context we have developed the python package pywpf to easily retrieve the period with the presented method. We applied this technique to sets of data of the brightest pulsars in visible light that we obtained with the fast photon counter Iqueye. Our results are compared with those obtained by different and more classical analyses (e.g., epoch folding), showing that the periods so determined agree within the errors, and that the errors associated to the waterfall-PCA folding technique are slightly smaller than those obtained by the $χ^2$ epoch folding technique. We also simulated extremely noisy situations, showing that by means of a new merit function associated to the waterfall-PCA folding it is possible to get more confidence on the determined period with respect to the $χ^2$ epoch folding technique.

astro-ph.IM

Radiation damage on SiPMs for Space Applications

Silicon Photo-multipliers (SiPMs) are very sensitive photo-detectors that experienced a big development in the last years in several applications, like LIDAR, astrophysics, medical imaging and high energy physics (HEP) experiments. In HEP experiments, in particular, they are often exposed to significant radiation doses. The main purpose of this manuscript is the characterization of several FBK SiPM technologies when exposed to 74 $MeV$ protons with a total fluence comparable to the one that they would experience in space along circular Low Earth Orbits (LEO), Polar, during a five years mission. In this work, we estimated the expected proton fluences along the selected orbit, by means of the SPENVIS software. Several fluence steps were chosen to consider dense fluence intervals and have a more accurate sight on the whole damage process. We estimated a maximum fluence achieved during the tests of $6.4 \times 10^{11}$ $n_{eq}/cm^2$. Based on such simulations, we irradiated several SiPM technologies. We developed a custom experimental setup, which was used to perform online reverse voltage-current, right after each irradiation step, to minimize the effect of the annealing on the measurement. The results are then displayed, in particular the currents, the noise and the Photon Detection Efficiency. Also a 30-days study on the annealing of the devices was performed. Lastly, the conclusions are drawn on the basis of the Signal-to-Noise Ratio (SNR), taking into account the standard parameters of famous satellites using similar orbits as the ones considered into this work.

physics.ins-det

Metis: the Solar Orbiter visible light and ultraviolet coronal imager

Metis is the first solar coronagraph designed for a space mission capable of performing simultaneous imaging of the off-limb solar corona in both visible and UV light. The observations obtained with Metis aboard the Solar Orbiter ESA-NASA observatory will enable us to diagnose, with unprecedented temporal coverage and spatial resolution, the structures and dynamics of the full corona from 1.7 $R_\odot$ to about 9 $R_\odot$. Due to the uniqueness of the Solar Orbiter mission profile, Metis will be able to observe the solar corona from a close vantage point (down to 0.28 AU), achieving out-of-ecliptic views with the increase of the orbit inclination over time. Moreover, observations near perihelion, during the phase of lower rotational velocity of the solar surface relative to the spacecraft, will allow longer-term studies of the coronal features. Thanks to a novel occultation design and a combination of a UV interference coating of the mirrors and a spectral bandpass filter, Metis images the solar corona simultaneously in the visible light band, between 580 and 640 nm, and in the UV H I Lyman-α line at 121.6 nm. The coronal images in both the UV Lyman-α and polarised visible light are obtained at high spatial resolution with a spatial scale down to about 2000 km and 15000 km at perihelion, in the cases of the visible and UV light, respectively. A temporal resolution down to 1 second can be achieved when observing coronal fluctuations in visible light. The Metis measurements will allow for complete characterisation of the main physical parameters and dynamics of the electron and neutral hydrogen/proton plasma components of the corona in the region where the solar wind undergoes acceleration and where the onset and initial propagation of coronal mass ejections take place, thus significantly improving our understanding of the region connecting the Sun to the heliosphere.

astro-ph.SR

A 3.9 km baseline intensity interferometry photon counting experiment

In the last years we have operated two very similar ultrafast photon counting photometers (Iqueye and Aqueye+) on different telescopes. The absolute time accuracy in time tagging the detected photon with these instruments is of the order of 500 ps for hours of observation, allowing us to obtain, for example, the most accurate ever light curve in visible light of the optical pulsars. Recently we adapted the two photometers for working together on two telescopes at Asiago (Italy), for realizing an Hanbury-Brown and Twiss Intensity Interferometry like experiment with two 3.9 km distant telescopes. In this paper we report about the status of the activity and on the very preliminary results of our first attempt to measure the photon intensity correlation.

astro-ph.IM