Searcharxiv⌕ Search

arXiv subjects

Enzo Ferrante

Publications and source records attributed to Enzo Ferrante.

At least 37 records · Page 2Linked to original sources

Performance Estimation for Supervised Medical Image Segmentation Models on Unlabeled Data Using UniverSeg

The performance of medical image segmentation models is usually evaluated using metrics like the Dice score and Hausdorff distance, which compare predicted masks to ground truth annotations. However, when applying the model to unseen data, such as in clinical settings, it is often impractical to annotate all the data, making the model's performance uncertain. To address this challenge, we propose the Segmentation Performance Evaluator (SPE), a framework for estimating segmentation models' performance on unlabeled data. This framework is adaptable to various evaluation metrics and model architectures. Experiments on six publicly available datasets across six evaluation metrics including pixel-based metrics such as Dice score and distance-based metrics like HD95, demonstrated the versatility and effectiveness of our approach, achieving a high correlation (0.956$\pm$0.046) and low MAE (0.025$\pm$0.019) compare with real Dice score on the independent test set. These results highlight its ability to reliably estimate model performance without requiring annotations. The SPE framework integrates seamlessly into any model training process without adding training overhead, enabling performance estimation and facilitating the real-world application of medical image segmentation algorithms. The source code is publicly available

eess.IV↗

Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI

Cardiovascular magnetic resonance imaging is emerging as a crucial tool to examine cardiac morphology and function. Essential to this endeavour are anatomical 3D surface and volumetric meshes derived from CMR images, which facilitate computational anatomy studies, biomarker discovery, and in-silico simulations. Traditional approaches typically follow complex multi-step pipelines, first segmenting images and then reconstructing meshes, making them time-consuming and prone to error propagation. In response, we introduce HybridVNet, a novel architecture for direct image-to-mesh extraction seamlessly integrating standard convolutional neural networks with graph convolutions, which we prove can efficiently handle surface and volumetric meshes by encoding them as graph structures. To further enhance accuracy, we propose a multi-view HybridVNet architecture which processes both long axis and short axis CMR, showing that it can increase the performance of cardiac MR mesh generation. Our model combines traditional convolutional networks with variational graph generative models, deep supervision and mesh-specific regularisation. Experiments on a comprehensive dataset from the UK Biobank confirm the potential of HybridVNet to significantly advance cardiac imaging and computational cardiology by efficiently generating high-fidelity meshes from CMR images. Multi-view HybridVNet outperforms the state-of-the-art, achieving improvements of up to $\sim$27\% reduction in Mean Contour Distance (from 1.86 mm to 1.35 mm for the LV Myocardium), up to $\sim$18\% improvement in Hausdorff distance (from 4.74 mm to 3.89mm, for the LV Endocardium), and up to $\sim$8\% in Dice Coefficient (from 0.78 to 0.84, for the LV Myocardium), highlighting its superior accuracy.

eess.IV↗

Global MMLU: Understanding and Addressing Cultural and Linguistic Biases in Multilingual Evaluation

Cultural biases in multilingual datasets pose significant challenges for their effectiveness as global benchmarks. These biases stem not only from differences in language but also from the cultural knowledge required to interpret questions, reducing the practical utility of translated datasets like MMLU. Furthermore, translation often introduces artefacts that can distort the meaning or clarity of questions in the target language. A common practice in multilingual evaluation is to rely on machine-translated evaluation sets, but simply translating a dataset is insufficient to address these challenges. In this work, we trace the impact of both of these issues on multilingual evaluations and ensuing model performances. Our large-scale evaluation of state-of-the-art open and proprietary models illustrates that progress on MMLU depends heavily on learning Western-centric concepts, with 28% of all questions requiring culturally sensitive knowledge. Moreover, for questions requiring geographic knowledge, an astounding 84.9% focus on either North American or European regions. Rankings of model evaluations change depending on whether they are evaluated on the full portion or the subset of questions annotated as culturally sensitive, showing the distortion to model rankings when blindly relying on translated MMLU. We release Global MMLU, an improved MMLU with evaluation coverage across 42 languages -- with improved overall quality by engaging with compensated professional and community annotators to verify translation quality while also rigorously evaluating cultural biases present in the original dataset. This comprehensive Global MMLU set also includes designated subsets labeled as culturally sensitive and culturally agnostic to allow for more holistic, complete evaluation.

cs.CL↗

Fairness of Deep Ensembles: On the interplay between per-group task difficulty and under-representation

Ensembling is commonly regarded as an effective way to improve the general performance of models in machine learning, while also increasing the robustness of predictions. When it comes to algorithmic fairness, heterogeneous ensembles, composed of multiple model types, have been employed to mitigate biases in terms of demographic attributes such as sex, age or ethnicity. Moreover, recent work has shown how in multi-class problems even simple homogeneous ensembles may favor performance of the worst-performing target classes. While homogeneous ensembles are simpler to implement in practice, it is not yet clear whether their benefits translate to groups defined not in terms of their target class, but in terms of demographic or protected attributes, hence improving fairness. In this work we show how this simple and straightforward method is indeed able to mitigate disparities, particularly benefiting under-performing subgroups. Interestingly, this can be achieved without sacrificing overall performance, which is a common trade-off observed in bias mitigation strategies. Moreover, we analyzed the interplay between two factors which may result in biases: sub-group under-representation and the inherent difficulty of the task for each group. These results revealed that, contrary to popular assumptions, having balanced datasets may be suboptimal if the task difficulty varies between subgroups. Indeed, we found that a perfectly balanced dataset may hurt both the overall performance and the gap between groups. This highlights the importance of considering the interaction between multiple forces at play in fairness.

cs.LG↗

ViG-Bias: Visually Grounded Bias Discovery and Mitigation

The proliferation of machine learning models in critical decision making processes has underscored the need for bias discovery and mitigation strategies. Identifying the reasons behind a biased system is not straightforward, since in many occasions they are associated with hidden spurious correlations which are not easy to spot. Standard approaches rely on bias audits performed by analyzing model performance in pre-defined subgroups of data samples, usually characterized by common attributes like gender or ethnicity when it comes to people, or other specific attributes defining semantically coherent groups of images. However, it is not always possible to know a-priori the specific attributes defining the failure modes of visual recognition systems. Recent approaches propose to discover these groups by leveraging large vision language models, which enable the extraction of cross-modal embeddings and the generation of textual descriptions to characterize the subgroups where a certain model is underperforming. In this work, we argue that incorporating visual explanations (e.g. heatmaps generated via GradCAM or other approaches) can boost the performance of such bias discovery and mitigation frameworks. To this end, we introduce Visually Grounded Bias Discovery and Mitigation (ViG-Bias), a simple yet effective technique which can be integrated to a variety of existing frameworks to improve both, discovery and mitigation performance. Our comprehensive evaluation shows that incorporating visual explanations enhances existing techniques like DOMINO, FACTS and Bias-to-Text, across several challenging datasets, including CelebA, Waterbirds, and NICO++.

cs.CV↗

Predicting risk of cardiovascular disease using retinal OCT imaging

Cardiovascular diseases (CVD) are the leading cause of death globally. Non-invasive, cost-effective imaging techniques play a crucial role in early detection and prevention of CVD. Optical coherence tomography (OCT) has gained recognition as a potential tool for early CVD risk prediction, though its use remains underexplored. In this study, we investigated the potential of OCT as an additional imaging technique to predict future CVD events. We analysed retinal OCT data from the UK Biobank. The dataset included 612 patients who suffered a myocardial infarction (MI) or stroke within five years of imaging and 2,234 controls without CVD (total: 2,846 participants). A self-supervised deep learning approach based on Variational Autoencoders (VAE) was used to extract low-dimensional latent representations from high-dimensional 3D OCT images, capturing distinct features of retinal layers. These latent features, along with clinical data, were used to train a Random Forest (RF) classifier to differentiate between patients at risk of future CVD events (MI or stroke) and healthy controls. Our model achieved an AUC of 0.75, sensitivity of 0.70, specificity of 0.70, and accuracy of 0.70, outperforming the QRISK3 score (the third version of the QRISK cardiovascular disease risk prediction algorithm; AUC = 0.60, sensitivity = 0.60, specificity = 0.55, accuracy = 0.55). The choroidal layer in OCT images was identified as a key predictor of future CVD events, revealed through a novel model explainability approach. This study demonstrates that retinal OCT imaging is a cost-effective, non-invasive alternative for predicting CVD risk, offering potential for widespread application in optometry practices and hospitals.

eess.IV↗

On dataset transferability in medical image classification

Current transferability estimation methods designed for natural image datasets are often suboptimal in medical image classification. These methods primarily focus on estimating the suitability of pre-trained source model features for a target dataset, which can lead to unrealistic predictions, such as suggesting that the target dataset is the best source for itself. To address this, we propose a novel transferability metric that combines feature quality with gradients to evaluate both the suitability and adaptability of source model features for target tasks. We evaluate our approach in two new scenarios: source dataset transferability for medical image classification and cross-domain transferability. Our results show that our method outperforms existing transferability metrics in both settings. We also provide insight into the factors influencing transfer performance in medical image classification, as well as the dynamics of cross-domain transfer from natural to medical images. Additionally, we provide ground-truth transfer performance benchmarking results to encourage further research into transferability estimation for medical image classification. Our code and experiments are available at https://github.com/DovileDo/transferability-in-medical-imaging.

cs.CV↗

SignAttention: On the Interpretability of Transformer Models for Sign Language Translation

This paper presents the first comprehensive interpretability analysis of a Transformer-based Sign Language Translation (SLT) model, focusing on the translation from video-based Greek Sign Language to glosses and text. Leveraging the Greek Sign Language Dataset, we examine the attention mechanisms within the model to understand how it processes and aligns visual input with sequential glosses. Our analysis reveals that the model pays attention to clusters of frames rather than individual ones, with a diagonal alignment pattern emerging between poses and glosses, which becomes less distinct as the number of glosses increases. We also explore the relative contributions of cross-attention and self-attention at each decoding step, finding that the model initially relies on video frames but shifts its focus to previously predicted tokens as the translation progresses. This work contributes to a deeper understanding of SLT models, paving the way for the development of more transparent and reliable translation systems essential for real-world applications.

cs.CL↗

Deep vessel segmentation with joint multi-prior encoding

The precise delineation of blood vessels in medical images is critical for many clinical applications, including pathology detection and surgical planning. However, fully-automated vascular segmentation is challenging because of the variability in shape, size, and topology. Manual segmentation remains the gold standard but is time-consuming, subjective, and impractical for large-scale studies. Hence, there is a need for automatic and reliable segmentation methods that can accurately detect blood vessels from medical images. The integration of shape and topological priors into vessel segmentation models has been shown to improve segmentation accuracy by offering contextual information about the shape of the blood vessels and their spatial relationships within the vascular tree. To further improve anatomical consistency, we propose a new joint prior encoding mechanism which incorporates both shape and topology in a single latent space. The effectiveness of our method is demonstrated on the publicly available 3D-IRCADb dataset. More globally, the proposed approach holds promise in overcoming the challenges associated with automatic vessel delineation and has the potential to advance the field of deep priors encoding.

eess.IV↗

Fitting Skeletal Models via Graph-based Learning

Skeletonization is a popular shape analysis technique that models an object's interior as opposed to just its boundary. Fitting template-based skeletal models is a time-consuming process requiring much manual parameter tuning. Recently, machine learning-based methods have shown promise for generating s-reps from object boundaries. In this work, we propose a new skeletonization method which leverages graph convolutional networks to produce skeletal representations (s-reps) from dense segmentation masks. The method is evaluated on both synthetic data and real hippocampus segmentations, achieving promising results and fast inference.

cs.CV↗

Source Matters: Source Dataset Impact on Model Robustness in Medical Imaging

Transfer learning has become an essential part of medical imaging classification algorithms, often leveraging ImageNet weights. The domain shift from natural to medical images has prompted alternatives such as RadImageNet, often showing comparable classification performance. However, it remains unclear whether the performance gains from transfer learning stem from improved generalization or shortcut learning. To address this, we conceptualize confounders by introducing the Medical Imaging Contextualized Confounder Taxonomy (MICCAT) and investigate a range of confounders across it -- whether synthetic or sampled from the data -- using two public chest X-ray and CT datasets. We show that ImageNet and RadImageNet achieve comparable classification performance, yet ImageNet is much more prone to overfitting to confounders. We recommend that researchers using ImageNet-pretrained models reexamine their model robustness by conducting similar experiments. Our code and experiments are available at https://github.com/DovileDo/source-matters.

cs.CV↗

Open Challenges on Fairness of Artificial Intelligence in Medical Imaging Applications

Recently, the research community of computerized medical imaging has started to discuss and address potential fairness issues that may emerge when developing and deploying AI systems for medical image analysis. This chapter covers some of the pressing challenges encountered when doing research in this area, and it is intended to raise questions and provide food for thought for those aiming to enter this research field. The chapter first discusses various sources of bias, including data collection, model training, and clinical deployment, and their impact on the fairness of machine learning algorithms in medical image computing. We then turn to discussing open challenges that we believe require attention from researchers and practitioners, as well as potential pitfalls of naive application of common methods in the field. We cover a variety of topics including the impact of biased metrics when auditing for fairness, the leveling down effect, task difficulty variations among subgroups, discovering biases in unseen populations, and explaining biases beyond standard demographic attributes.

cs.CV↗

FUTURE-AI: International consensus guideline for trustworthy and deployable artificial intelligence in healthcare

Despite major advances in artificial intelligence (AI) for medicine and healthcare, the deployment and adoption of AI technologies remain limited in real-world clinical practice. In recent years, concerns have been raised about the technical, clinical, ethical and legal risks associated with medical AI. To increase real world adoption, it is essential that medical AI tools are trusted and accepted by patients, clinicians, health organisations and authorities. This work describes the FUTURE-AI guideline as the first international consensus framework for guiding the development and deployment of trustworthy AI tools in healthcare. The FUTURE-AI consortium was founded in 2021 and currently comprises 118 inter-disciplinary experts from 51 countries representing all continents, including AI scientists, clinicians, ethicists, and social scientists. Over a two-year period, the consortium defined guiding principles and best practices for trustworthy AI through an iterative process comprising an in-depth literature review, a modified Delphi survey, and online consensus meetings. The FUTURE-AI framework was established based on 6 guiding principles for trustworthy AI in healthcare, i.e. Fairness, Universality, Traceability, Usability, Robustness and Explainability. Through consensus, a set of 28 best practices were defined, addressing technical, clinical, legal and socio-ethical dimensions. The recommendations cover the entire lifecycle of medical AI, from design, development and validation to regulation, deployment, and monitoring. FUTURE-AI is a risk-informed, assumption-free guideline which provides a structured approach for constructing medical AI tools that will be trusted, deployed and adopted in real-world practice. Researchers are encouraged to take the recommendations into account in proof-of-concept stages to facilitate future translation towards clinical practice of medical AI.

cs.CY↗

Are demographically invariant models and representations in medical imaging fair?

Medical imaging models have been shown to encode information about patient demographics such as age, race, and sex in their latent representation, raising concerns about their potential for discrimination. Here, we ask whether requiring models not to encode demographic attributes is desirable. We point out that marginal and class-conditional representation invariance imply the standard group fairness notions of demographic parity and equalized odds, respectively. In addition, however, they require matching the risk distributions, thus potentially equalizing away important group differences. Enforcing the traditional fairness notions directly instead does not entail these strong constraints. Moreover, representationally invariant models may still take demographic attributes into account for deriving predictions, implying unequal treatment - in fact, achieving representation invariance may require doing so. In theory, this can be prevented using counterfactual notions of (individual) fairness or invariance. We caution, however, that properly defining medical image counterfactuals with respect to demographic attributes is fraught with challenges. Finally, we posit that encoding demographic attributes may even be advantageous if it enables learning a task-specific encoding of demographic features that does not rely on social constructs such as 'race' and 'gender.' We conclude that demographically invariant representations are neither necessary nor sufficient for fairness in medical imaging. Models may need to encode demographic attributes, lending further urgency to calls for comprehensive model fairness assessments in terms of predictive performance across diverse patient groups.

cs.LG↗

CheXmask: a large-scale dataset of anatomical segmentation masks for multi-center chest x-ray images

The development of successful artificial intelligence models for chest X-ray analysis relies on large, diverse datasets with high-quality annotations. While several databases of chest X-ray images have been released, most include disease diagnosis labels but lack detailed pixel-level anatomical segmentation labels. To address this gap, we introduce an extensive chest X-ray multi-center segmentation dataset with uniform and fine-grain anatomical annotations for images coming from five well-known publicly available databases: ChestX-ray8, Chexpert, MIMIC-CXR-JPG, Padchest, and VinDr-CXR, resulting in 657,566 segmentation masks. Our methodology utilizes the HybridGNet model to ensure consistent and high-quality segmentations across all datasets. Rigorous validation, including expert physician evaluation and automatic quality control, was conducted to validate the resulting masks. Additionally, we provide individualized quality indices per mask and an overall quality estimation per dataset. This dataset serves as a valuable resource for the broader scientific community, streamlining the development and assessment of innovative methodologies in chest X-ray analysis. The CheXmask dataset is publicly available at: https://physionet.org/content/chexmask-cxr-segmentation-data/

eess.IV↗

Supervision by Denoising for Medical Image Segmentation

Learning-based image reconstruction models, such as those based on the U-Net, require a large set of labeled images if good generalization is to be guaranteed. In some imaging domains, however, labeled data with pixel- or voxel-level label accuracy are scarce due to the cost of acquiring them. This problem is exacerbated further in domains like medical imaging, where there is no single ground truth label, resulting in large amounts of repeat variability in the labels. Therefore, training reconstruction networks to generalize better by learning from both labeled and unlabeled examples (called semi-supervised learning) is problem of practical and theoretical interest. However, traditional semi-supervised learning methods for image reconstruction often necessitate handcrafting a differentiable regularizer specific to some given imaging problem, which can be extremely time-consuming. In this work, we propose "supervision by denoising" (SUD), a framework that enables us to supervise reconstruction models using their own denoised output as soft labels. SUD unifies stochastic averaging and spatial denoising techniques under a spatio-temporal denoising framework and alternates denoising and model weight update steps in an optimization framework for semi-supervision. As example applications, we apply SUD to two problems arising from biomedical imaging -- anatomical brain reconstruction (3D) and cortical parcellation (2D) -- to demonstrate a significant improvement in the image reconstructions over supervised-only and stochastic averaging baselines.

eess.IV↗

Unsupervised bias discovery in medical image segmentation

It has recently been shown that deep learning models for anatomical segmentation in medical images can exhibit biases against certain sub-populations defined in terms of protected attributes like sex or ethnicity. In this context, auditing fairness of deep segmentation models becomes crucial. However, such audit process generally requires access to ground-truth segmentation masks for the target population, which may not always be available, especially when going from development to deployment. Here we propose a new method to anticipate model biases in biomedical image segmentation in the absence of ground-truth annotations. Our unsupervised bias discovery method leverages the reverse classification accuracy framework to estimate segmentation quality. Through numerical experiments in synthetic and realistic scenarios we show how our method is able to successfully anticipate fairness issues in the absence of ground-truth labels, constituting a novel and valuable tool in this field.

cs.CV↗

Maximum Entropy on Erroneous Predictions (MEEP): Improving model calibration for medical image segmentation

Modern deep neural networks achieved remarkable progress in medical image segmentation tasks. However, it has recently been observed that they tend to produce overconfident estimates, even in situations of high uncertainty, leading to poorly calibrated and unreliable models. In this work we introduce Maximum Entropy on Erroneous Predictions (MEEP), a training strategy for segmentation networks which selectively penalizes overconfident predictions, focusing only on misclassified pixels. Our method is agnostic to the neural architecture, does not increase model complexity and can be coupled with multiple segmentation loss functions. We benchmark the proposed strategy in two challenging segmentation tasks: white matter hyperintensity lesions in magnetic resonance images (MRI) of the brain, and atrial segmentation in cardiac MRI. The experimental results demonstrate that coupling MEEP with standard segmentation losses leads to improvements not only in terms of model calibration, but also in segmentation quality.

cs.CV↗