Searcharxiv⌕ Search

arXiv subjects

Erich Leistenschneider

Publications and source records attributed to Erich Leistenschneider.

2 recordsLinked to original sources

The mass of $^{101}$Sn and Bayesian extrapolations to the proton drip line

The favorable energy configurations of nuclei at magic numbers of ${N}$ neutrons and ${Z}$ protons are fundamental for understanding the evolution of nuclear structure. The ${Z=50}$ (tin) isotopic chain is a frontier for such studies, with particular interest at and around the doubly-magic \textsuperscript{100}Sn isotope, for which the mass is a topic of debate. Precise mass values for neutron-deficient isotopes provide necessary anchor points for mass models to test extrapolations near the proton drip line, where experimental studies remain out of reach. In this work, we report the first Penning trap mass measurement of \textsuperscript{101}Sn. The determined mass excess of $-59\,889.89(96)$~keV for \textsuperscript{101}Sn represents a factor of 300 improvement over the current precision and indicates that \textsuperscript{101}Sn is less bound than previously thought. Mass predictions from a recently developed Bayesian model combination (BMC) framework employing statistical machine learning and nuclear masses computed within seven global models based on nuclear Density Functional Theory (DFT) agree within 1$σ$ with experimental masses from the $48 \le Z \le 52$ isotopic chains. The framework's resilience to new mass data gave confidence in the extrapolation of tin masses down to $N=46$. Our calculations suggest that \textsuperscript{96}Sn is a two-proton drip line nucleus and predict a mass excess of $-58\,090(800)$~keV for $^{100}$Sn, showing a preference within 1$σ$ for the mass of \textsuperscript{100}Sn derived from the $β$-delayed $Q$-value measured at GSI.

nucl-ex↗

Enhancing the mass resolving power of FRIB's proposed high-voltage MR-ToF mass separator and spectrometer: addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of \( m / Δm = 10^6 \). Achieving \( m / Δm > 3 \cdot 10^6 \) would provide the ability to resolve \( >90\% \) of all known isomeric states with half-lives above 10~\text{ms}. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. To this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30~\text{keV} beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at \( <3~\text{keV} \) beam energy will already enable mass resolving powers approaching \( 10^6 \) for FRIB's high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching \( 10^7 \) might become feasible.

physics.ins-det↗