SearcharxivSearch

arXiv subjects

Esteve Farres

Publications and source records attributed to Esteve Farres.

3 recordsLinked to original sources

Soil Moisture Monitorization Using GNSS Reflected Signals

The use of GNSS signals as a source of opportunity for remote sensing applications, GNSS-R, has been a research area of interest for more than a decade. One of the possible applications of this technique is soil moisture monitoring. The retrieval of soil moisture with GNSS-R systems is based on the variability of the ground dielectric properties associated to soil moisture. Higher concentrations of water in the soil yield a higher dielectric constant and reflectivity, which incurs in signals that reflect from the Earth surface with higher peak power. Previous investigations have demonstrated the capability of GPS bistatic scatterometers to obtain high enough signal to noise ratios in order to sense small changes in surface reflectivity. Furthermore, these systems present some advantages with respect to others currently used to retrieve soil moisture. Upcoming satellite navigation systems, such as the European Galileo, will represent an excellent source of opportunity for soil moisture remote sensing for various reasons. First, the existence of pilot signals will provide the possibility to extend coherent integration times, which will contribute to the increase of received signals SNR. In addition, the availability of Galileo L1 and L5 signals will allow the multi-spectral analysis of the reflected signals and the development of inversion models which will be able to account more precisely for adverse effects, such as surface roughness and vegetation canopy. In this paper we present some of the recent theoretical work and experiments carried out at Starlab focusing on the development of dedicated Soil Moisture GNSS-R systems.

physics.geo-ph

ENOBIO - First tests of a dry electrophysiology electrode using carbon nanotubes

We describe the development and first tests of Enobio, a dry electrode sensor concept for biopotential applications. In the proposed electrodes, the tip of the electrode is covered with a forest of multi-walled CNTs that can be coated with Ag/AgCl to provide ionic-electronic transduction. The CNT brush-like structure is to penetrate the outer layers of the skin improving electrical contact as well as increae the contact surface area. In this paper, we report the results of the first tests of this concept -- immersion on saline solution and pig skin signal detection. These indicate performance on a par with state of the art research-oriented wet electrodes.

physics.med-ph

A dry electrophysiology electrode using CNT arrays

We describe the concept of a dry electrode sensor for biopotential measurement applications (ENOBIO) designed to eliminate the noise and inconvenience associated to the use of electrolytic gel. ENOBIO uses nanotechnology to remove gel-related noise, as well as maintaining a good contact impedance to minimise interference noise. The contact surface of the electrode will be covered with an array/forest of carbon nanotubes and will also be tested with an Ag/AgCl coating to provide ionic-electronic transduction. The nanotubes are to penetrate the outer layers of the skin, the Stratum Corneum, improving electrical contact. We discuss requirements, skin properties, nanotube penetration and transduction, noise sources, prototype design logic and biocompatibility. A future paper will report test results.

physics.med-ph