SearcharxivSearch

arXiv subjects

Esther Baumann

Publications and source records attributed to Esther Baumann.

12 recordsLinked to original sources

Broadband dual-comb hyperspectral imaging and adaptable spectroscopy with programmable frequency combs

We explore the advantages of a free-form dual-comb spectroscopy (DCS) platform based on time-programmable frequency combs for real-time, penalty-free apodized scanning. In traditional DCS, the fundamental spectral resolution, which equals the comb repetition rate, can be excessively fine for many applications. While the fine resolution is not itself problematic, it comes with the penalty of excess acquisition time. Post-processing apodization (windowing) can be applied to tailor the resolution to the sample, but only with a deadtime penalty proportional to the degree of apodization. The excess acquisition time remains. With free-form DCS, this deadtime is avoided by programming a real-time apodization pattern that dynamically reverses the pulse periods between the dual frequency combs. In this way, one can tailor the spectrometer's resolution and update rate to different applications without penalty. We show operation of a free-form DCS system where the spectral resolution is varied from the intrinsic fine resolution of 160 MHz up to 822 GHz by applying tailored real-time apodization. Because there is no deadtime penalty, the spectral signal-to-noise ratio increases linearly with resolution by 5000x over this range, as opposed to the square root increase observed for postprocessing apodization in traditional DCS. We explore the flexibility to change resolution and update rate to perform hyperspectral imaging at slow camera frame rates, where the penalty-free apodization allows for optimal use of each frame. We obtain dual-comb hyperspectral movies at a 20 Hz spectrum update rate with broad optical spectral coverage of over 10 THz.

physics.optics

10 GHz Generation with Ultra-Low Phase Noise via the Transfer Oscillator Technique

Coherent frequency division of high-stability optical sources permits the extraction of microwave signals with ultra-low phase noise, enabling their application to systems with stringent timing precision. To date, the highest performance systems have required tight phase stabilization of laboratory grade optical frequency combs to Fabry-Perot optical reference cavities for faithful optical-to-microwave frequency division. This requirement limits the technology to highly-controlled laboratory environments. Here, we employ a transfer oscillator technique, which employs digital and RF analog electronics to coherently suppress additive optical frequency comb noise. This relaxes the stabilization requirements and allows for the extraction of multiple independent microwave outputs from a single comb, while at the same time, permitting low-noise microwave generation from combs with higher noise profiles. Using this method we transferred the phase stability of two high-Finesse optical sources at 1157 nm and 1070 nm to two independent 10 GHz signals using a single frequency comb. We demonstrated absolute phase noise below -106 dBc/Hz at 1-Hz from carrier with corresponding 1 second fractional frequency instability below $2\times10^{-15}$. Finally, the latter phase noise levels were attainable for comb linewidths broadened up to 2 MHz, demonstrating the potential for out-of lab use with low SWaP lasers.

physics.optics

20 years of developments in optical frequency comb technology and applications

Optical frequency combs were developed nearly two decades ago to support the world's most precise atomic clocks. Acting as precision optical synthesizers, frequency combs enable the precise transfer of phase and frequency information from a high-stability reference to hundreds of thousands of tones in the optical domain. This versatility, coupled with near-continuous spectroscopic coverage from the terahertz to the extreme ultra-violet, has enabled precision measurement capabilities in both fundamental and applied contexts. This review takes a tutorial approach to illustrate how 20 years of source development and technology has facilitated the journey of optical frequency combs from the lab into the field.

physics.optics

Dual-comb spectroscopy with tailored spectral broadening in Si$_3$N$_4$ nanophotonics

Si$_3$N$_4$ waveguides, pumped at 1550 nm, can provide spectrally smooth, broadband light for gas spectroscopy in the important 2 ${\mathrmμ}$m to 2.5 ${\mathrmμ}$m atmospheric water window, which is only partially accessible with silica-fiber based systems. By combining Er+:fiber frequency combs and supercontinuum generation in tailored Si$_3$N$_4$ waveguides, high signal-to-noise dual-comb spectroscopy (DCS) spanning 2 ${\mathrmμ}$m to 2.5 ${\mathrmμ}$m is demonstrated. Acquired broadband dual-comb spectra of CO and CO$_2$ agree well with database line shape models and have a spectral-signal-to-noise as high as 48$/\sqrt{\mathrm{s}}$, showing that the high coherence between the two combs is retained in the Si$_3$N$_4$ supercontinuum generation. The DCS figure of merit is 6$\times 10^6/\sqrt{\mathrm{s}}$, equivalent to that of all-fiber DCS systems in the 1.6 ${\mathrmμ}$m band. Based on these results, future DCS can combine fiber comb technology with Si$_3$N$_4$ waveguides to access new spectral windows in a robust non-laboratory platform.

physics.optics

Fully self-referenced frequency comb consuming 5 Watts of electrical power

We present a hybrid fiber/waveguide design for a 100-MHz frequency comb that is fully self-referenced and temperature controlled with less than 5 W of electrical power. Self-referencing is achieved by supercontinuum generation in a silicon nitride waveguide, which requires much lower pulse energies (~200 pJ) than with highly nonlinear fiber. These low-energy pulses are achieved with an erbium fiber oscillator/amplifier pumped by two 250-mW passively-cooled pump diodes that consume less than 5 W of electrical power. The temperature tuning of the oscillator, necessary to stabilize the repetition rate in the presence of environmental temperature changes, is achieved by resistive heating of a section of gold-palladium-coated fiber within the laser cavity. By heating only the small thermal mass of the fiber, the repetition rate is tuned over 4.2 kHz (corresponding to an effective temperature change of 4.2 °C) with a fast time constant of 0.5 s, at a low power consumption of 0.077 W/°C, compared to 2.5 W/°C in the conventional 200-MHz comb design.

physics.ins-det

Continuous regional trace gas source attribution using a field-deployed dual frequency comb spectrometer

Identification and quantification of trace gas sources is a major challenge for understanding and regulating air quality and greenhouse gas emissions. Current approaches either provide continuous but localized monitoring, or quasi-instantaneous 'snapshot-in-time' regional monitoring. There is a need for emissions detection that provides both continuous and regional coverage, because sources and sinks can be episodic and spatially variable. We field deploy a dual frequency comb laser spectrometer for the first time, enabling an observing system that provides continuous detection of trace gas sources over multiple-square-kilometer regions. Field tests simulating methane emissions from oil and gas production demonstrate detection and quantification of a 1.6 g min^-1 source (approximate emissions from a small pneumatic valve) from a distance of 1 km, and the ability to discern two leaks among a field of many potential sources. The technology achieves the goal of detecting, quantifying, and attributing emissions sources continuously through time, over large areas, and at emissions rates ~1000x lower than current regional approaches. It therefore provides a useful tool for monitoring and mitigating undesirable sources and closes a major information gap in the atmospheric sciences.

physics.ao-ph

Comparing optical oscillators across the air to milliradians in phase and $10^{-17}$ in frequency

We demonstrate carrier-phase optical two-way time-frequency transfer (carrier-phase OTWTFT) through the two-way exchange of frequency comb pulses. Carrier-phase OTWTFT achieves frequency comparisons with a residual instability of 1.2x10$^{-17}$ at 1 second across a turbulent 4-km free space link, surpassing previous OTWTFT by 10-20x and enabling future high-precision optical clock networks. Furthermore, by exploiting the carrier-phase, this approach is able to continuously track changes in the relative optical phase of distant optical oscillators to 9 mrad (7 attoseconds) at 1-sec averaging, effectively extending optical phase coherence over a broad spatial network for applications such as correlated spectroscopy between distant atomic clocks.

physics.ins-det

High Coherence Mid-Infrared Dual Comb Spectroscopy Spanning 2.6 to 5.2 microns

Mid-infrared dual-comb spectroscopy has the potential to supplant conventional high-resolution Fourier transform spectroscopy in applications that require high resolution, accuracy, signal-to-noise ratio, and speed. Until now, dual-comb spectroscopy in the mid-infrared has been limited to narrow optical bandwidths or to low signal-to-noise ratios. Using a combination of digital signal processing and broadband frequency conversion in waveguides, we demonstrate a mid-infrared dual-comb spectrometer that can measure comb-tooth resolved spectra across an octave of bandwidth in the mid-infrared from 2.6-5.2 $μ$m with sub-MHz frequency precision and accuracy and with a spectral signal-to-noise ratio as high as 6500. As a demonstration, we measure the highly structured, broadband cross-section of propane (C3H8) in the 2860-3020 cm-1 region, the complex phase/amplitude spectrum of carbonyl sulfide (COS) in the 2000 to 2100 cm-1 region, and the complex spectra of methane, acetylene, and ethane in the 2860-3400 cm-1 region.

physics.optics

Accurate frequency referencing for fieldable dual-comb spectroscopy

A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full comb-tooth resolution spanning from 140 THz (2.14 um, 4670 cm^-1) to 184 THz (1.63 um, 6140 cm^-1) in the near infrared with a frequency sampling of 200 MHz (0.0067 cm^-1), ~ 120 kHz frequency resolution, and ~ 1 MHz frequency accuracy. High resolution spectra of water and carbon dioxide transitions at 1.77 um, 1.96 um and 2.06 um show that the molecular transmission acquired with this fieldable system did not deviate from those measured with a laboratory-based system (referenced to a maser and cavity-stabilized laser) to within 5.6x10^-4. Additionally, the fieldable system optimized for carbon dioxide quantification at 1.60 um, demonstrated a sensitivity of 2.8 ppm-km at 1 s integration time, improving to 0.10 ppm-km at 13 minutes of integration time.

physics.ins-det

Synchronization of Distant Optical Clocks at the Femtosecond Level

The use of optical clocks/oscillators in future ultra-precise navigation, gravitational sensing, coherent arrays, and relativity experiments will require time comparison and synchronization over terrestrial or satellite free-space links. Here we demonstrate full unambiguous synchronization of two optical timescales across a free-space link. The time deviation between synchronized timescales is below 1 fs over durations from 0.1 s to 6500 s, despite atmospheric turbulence and kilometer-scale path length variations. Over several days, the time wander is 40 fs peak-to-peak. Our approach relies on the two-way reciprocity of a single-spatial-mode optical link, valid to below 225 attoseconds across a turbulent 4-km path. This femtosecond level of time-frequency transfer should enable optical networks using state-of-the-art optical clocks/oscillators.

physics.optics

Frequency Comb-Based Remote Sensing of Greenhouse Gases over Kilometer Air Paths

We demonstrate coherent dual frequency-comb spectroscopy for detecting variations in greenhouse gases. High signal-to-noise spectra are acquired spanning 5990 to 6260 cm^-1 (1600 to 1670 nm) covering ~700 absorption features from CO2, CH4, H2O, HDO, and 13CO2, across a 2-km open-air path. The transmission of each frequency comb tooth is resolved, leading to spectra with <1 kHz frequency accuracy, no instrument lineshape, and a 0.0033-cm^-1 point spacing. The fitted path-averaged concentrations and temperature yield dry-air mole fractions. These are compared with a point sensor under well-mixed conditions to evaluate current absorption models for real atmospheres. In heterogeneous conditions, time-resolved data demonstrate tracking of strong variations in mole fractions. A precision of <1 ppm for CO2 and <3 ppb for CH4 is achieved in 5 minutes in this initial demonstration. Future portable systems could support regional emissions monitoring and validation of the spectral databases critical to global satellite-based trace gas monitoring.

physics.optics

Optical two-way time and frequency transfer over free space

The transfer of high-quality time-frequency signals between remote locations underpins a broad range of applications including precision navigation and timing, the new field of clock-based geodesy, long-baseline interferometry, coherent radar arrays, tests of general relativity and fundamental constants, and the future redefinition of the second [1-7]. However, present microwave-based time-frequency transfer [8-10] is inadequate for state-of-the-art optical clocks and oscillators [1,11-15] that have femtosecond-level timing jitter and accuracies below 1E-17; as such, commensurate optically-based transfer methods are needed. While fiber-based optical links have proven suitable [16,17], they are limited to comparisons between fixed sites connected by a specialized bidirectional fiber link. With the exception of tests of the fundamental constants, most applications instead require more flexible connections between remote and possibly portable optical clocks and oscillators. Here we demonstrate optical time-frequency transfer over free-space via a two-way exchange between coherent frequency combs, each phase-locked to the local optical clock or oscillator. We achieve femtosecond-scale timing deviation, a residual instability below 1E-18 at 1000 s and systematic offsets below 4E-19, despite frequent signal fading due to atmospheric turbulence or obstructions across the 2-km link. This free-space transfer would already enable terrestrial links to support clock-based geodesy. If combined with satellite-based free-space optical communications, it provides a path toward global-scale geodesy, high-accuracy time-frequency distribution, satellite-based relativity experiments, and "optical GPS" for precision navigation.

physics.optics