SearcharxivSearch

arXiv subjects

Ettore Majorana

Publications and source records attributed to Ettore Majorana.

6 recordsLinked to original sources

Cryogenic payloads for the Einstein Telescope -- Baseline design with heat extraction, suspension thermal noise modelling and sensitivity analyses

The Einstein Telescope (ET) is a third generation gravitational wave detector that includes a room-temperature high-frequency (ET-HF) and a cryogenic low-frequency laser interferometer (ET-LF). The cryogenic ET-LF is crucial for exploiting the full scientific potential of ET. We present a new baseline design for the cryogenic payload that is thermally and mechanically consistent and compatible with the design sensitivity curve of ET. The design includes two options for the heat extraction from the marionette, based on a monocrystalline high-conductivity marionette suspension fiber and a thin-wall titanium tube filled with static He-II, respectively. Following a detailed description of the design options and the suspension thermal noise (STN) modelling, we present the sensitivity curves of the two baseline designs, discuss the influence of various design parameters on the sensitivity of ET-LF and conclude with an outlook to future R&D activities.

astro-ph.IM

3G R&D: R&D for the Next Generation of Ground-based Gravitational-wave Detectors

To deliver on the promise of next generation gravitational-wave observatories, a sustained and coordinated detector research and development program is required. This report examines in detail the wide range of nearer- and longer-term detector R&D programs needed for next generation GW detectors commensurate with the key science targets presented in "The Next Generation Global Gravitational Wave Observatory: The Science Book", including considerations of site selection and large-scale vacuum infrastructure. The report makes a series of detailed recommendations on the needed advances in detector technology and the timescales needed to achieve those advances. It also identifies areas where larger-scale globally coordinated R&D efforts will be critical to ensuring success while minimizing costs. This report is the third in a six part series of reports by the GWIC 3G Subcommittee: i) Expanding the Reach of Gravitational Wave Observatories to the Edge of the Universe, ii) The Next Generation Global Gravitational Wave Observatory: The Science Book, iii) 3G R&D: R&D for the Next Generation of Ground-based Gravitational Wave Detectors (this report), iv) Gravitational Wave Data Analysis: Computing Challenges in the 3G Era, v) Future Ground-based Gravitational-wave Observatories: Synergies with Other Scientific Communities, and vi) An Exploration of Possible Governance Models for the Future Global Gravitational-Wave Observatory Network.

gr-qc

Cryogenic suspension design for a kilometer-scale gravitational-wave detector

We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.

physics.ins-det

The Archimedes experiment

Archimedes is an INFN-funded pathfinder experiment aimed at verifying the feasibility of measuring the interaction of vacuum fluctuations with gravity. The final experiment will measure the force exerted by the gravitational field on a Casimir cavity whose vacuum energy is modulated with a superconductive transition, by using a balance as a small force detector. Archimedes is a two-year project devoted to test the most critical experimental aspects, in particular the balance resonance frequency and quality factor, the thermal modulation efficiency and the superconductive sample realization.

gr-qc

The Archimedes project: a feasibility study for weighing the vacuum energy

Archimedes is a feasibility study to a future experiment to ascertain the interaction of vacuum fluctuations with gravity. The future experiment should measure the force that the Earth's gravitational field exerts on a Casimir cavity by using a balance as the small force detector. The Archimedes experiment analyses the important parameters in view of the final measurement and experimentally explores solutions to the most critical problems.

gr-qc

Evaluation of heat extraction through sapphire fibers for the GW observatory KAGRA

Currently, the Japanese gravitational wave laser interferometer KAGRA is under construction in the Kamioka mine. As one main feature, it will employ sapphire mirrors operated at a temperature of 20K to reduce the impact from thermal noise. To reduce seismic noise, the mirrors will also be suspended from multi-stage pendulums. Thus the heat load deposited in the mirrors by absorption of the circulating laser light as well as heat load from thermal radiation will need to be extracted through the last suspension stage. This stage will consist of four thin sapphire fibers with larger heads necessary to connect the fibers to both the mirror and the upper stage. In this paper, we discuss heat conductivity measurements on different fiber candidates. While all fibers had a diameter of 1.6mm, different surface treatments and approaches to attach the heads were analyzed. Our measurements show that fibers fulfilling the basic KAGRA heat conductivity requirement of $κ\geq $5000W/m/K at 20K are technologically feasible.

astro-ph.IM