SearcharxivSearch

arXiv subjects

Eva Gassner

Publications and source records attributed to Eva Gassner.

3 recordsLinked to original sources

Stacked Ensemble Learning for Abdominal Aortic Aneurysm Segmentation in CT Angiography

Abdominal aortic aneurysm (AAA) rupture risk assessment increasingly relies on patient-specific biomechanical computations, which require accurate three-dimensional aneurysm geometry from computed tomography angiography (CTA). Manual and semi-automated segmentation remain time-consuming and observer-dependent, limiting their use in large-scale clinical workflows. In this study, we developed a stacked ensemble framework for automated AAA seg-mentation from CTA images. We used 40 anonymised contrast-enhanced CTA scans from AAA patients and generated reference segmentations using the nnInteractive extension in 3D Slicer. We partitioned the dataset into 32 training cases and 8 held-out test cases. Three nnUNetv2 configurations, Default, DA5, and ResEncL, were trained as base learners, and their voxel-wise probability out-puts were combined using an L2-regularised logistic regression meta-model trained from out-of-sample cross-validation predictions. We evaluated segmentation performance using Dice Coefficient and Separation Distance, a mean boundary-to-boundary distance measure introduced in this study to quantify average surface agreement. On the held-out test set, the ensemble achieved the highest mean Dice Coefficient of 0.9752 and the lowest mean Separation Distance of 0.4598 mm, indicating improved volumetric overlap and average boundary agreement compared with the individual base learners. Overall, stacked ensemble learning provided small but meaningful improvements in AAA segmentation, particularly for boundary accuracy relevant to downstream patient-specific bio-mechanical computations.

cs.CE

Towards personalised assessment of abdominal aortic aneurysm structural integrity

Abdominal aortic aneurysm (AAA) is a life-threatening condition characterized by the progressive dilation of the aorta, which can lead to rupture if undetected or untreated. Stress-based rupture risk estimation using computational biomechanics has been widely studied; however, it requires wall strength data that cannot be measured in humans in vivo. To overcome this limitation, the goal of this study is to present a new method for biomechanical assessment of AAA via simultaneous consideration of tension and strain in AAA wall. We present a patient-specific, non-invasive method for assessing the structural integrity of the AAA wall using only time-resolved 3D computed tomography angiography (4D-CTA) images and blood pressure data. The proposed approach integrates wall strain (throughout the cardiac cycle) and wall tension analysis to compute a novel index, the Relative Structural Integrity Index (RSII), which quantifies local wall stiffness independently of wall thickness, wall material properties, and blood pressure measurement conditions. We applied our method to twenty patients from three different hospitals to extract visual RSII maps over the AAA wall of each individual patient and to compare the RSII values between aneurysmal and non-aneurysmal aortas in one patient. Our results primarily show similar RSII values across all patients, indicating the consistency of the method. Additionally, we observed patterns consistent with experimental findings reported in the literature: AAA walls exhibited higher stiffness than healthy aortic walls, while localized low-stiffness zones in the AAA wall were predominantly found in the most dilated regions.

cs.CE

Towards Full Automation of Geometry Extraction for Biomechanical Analysis of Abdominal Aortic Aneurysm; Neural Network-Based versus Classical Methodologies

Background: For the clinical adoption of stress-based rupture risk estimation in abdominal aortic aneurysms (AAAs), a fully automated pipeline, from clinical imaging to biomechanical stress computation, is essential. To this end, we investigated the impact of AI-based image segmentation methods on stress computation results in the walls of AAAs. We compared wall stress distributions and magnitudes calculated from geometry models obtained from classical semi-automated segmentation versus automated neural network-based segmentation. Method: 16 different AAA contrast-enhanced computed tomography (CT) images were semi-automatically segmented by an analyst, taking between 15 and 40 minutes of human effort per patient, depending on image quality. The same images were automatically segmented using PRAEVAorta2 commercial software by NUREA (https://www.nurea-soft.com/), developed based on artificial intelligence (AI) algorithms, and automatically post-processed with an in-house MATLAB code, requiring only 1-2 minutes of computer time per patient. Aneurysm wall stress calculations were automatically performed using the BioPARR software (https://bioparr.mech.uwa.edu.au/). Results: Compared to the classical semi-automated segmentation, the automatic neural network-based segmentation leads to equivalent stress distributions, and slightly higher peak and 99th percentile maximum principal stress values. However, our statistical analysis indicated that the differences in AAA wall stress obtained using the two segmentation methods are not statistically significant and fall well within the typical range of inter-analyst and intra-analyst variability. Conclusions: Our findings are a steppingstone toward a fully automated pipeline for biomechanical analysis of AAAs, starting with CT scans and concluding with wall stress assessment.

cs.CE