SearcharxivSearch

arXiv subjects

Eva Sicking

Publications and source records attributed to Eva Sicking.

9 recordsLinked to original sources

Temperature dependence of the long-term annealing behavior of neutron irradiated diodes from 8-inch p-type silicon wafers

To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL) concept. The high-radiation regions of the the CE, where fluences between $1\cdot10^{14}~n_{eq}/cm^{2}$ and $1\cdot10^{16}~n_{eq}/cm^{2}$ and doses of up to 2\,MGy are expected considering an integrated luminosity of $3\,ab^{-1}$, will be equipped with silicon pad sensors. This includes the entire electromagnetic as well as parts of the hadronic section of the CE. The silicon sensors are processed on 8-inch p-type wafers with an active thickness of 300\,\textmu m, 200\,\textmu m and 120\,\textmu m and cut into hexagonal shapes for optimal use of the full wafer area and tiling. With each main sensor, several small test structures (e.g. pad diodes) are hosted on the wafers, used for quality assurance and radiation hardness tests. In order to investigate the radiation-induced bulk damage, these diodes have been irradiated with reactor neutrons at JSI (Jozef Stefan Institute, Ljubljana, Slovenia) to fluences between $5\cdot10^{14}~n_{eq}/cm^{2}$ and $1.5\cdot10^{16}~n_{eq}/cm^{2}$. This study focuses on the isothermal annealing behavior of the bulk material at different temperatures between 5.5{\deg}C and 60{\deg}C using electrical characterization and charge collection measurements. The results are used to extract the annealing time constants for this material and fluence range based on the Hamburg model approach to allow an estimation of the expected annealing effects in silicon sensors during the year-end technical stops and the long HL-LHC shutdowns. The annealing parameters found will make it possible to model the annealing behavior of p-type silicon detector projects at HL-LHC fluence ranges better than the existing Hamburg model.

physics.ins-det

The Compact Linear e$^+$e$^-$ Collider (CLIC)

The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e$^+$e$^-$ collider studied by the international CLIC and CLICdp collaborations. CLIC uses a two-beam acceleration scheme, in which normal-conducting high-gradient 12 GHz accelerating structures are powered via a high-current drive beam. CLIC is foreseen to be built and operated in stages. The initial 380 GeV stage, with a site length of 11 km, optimally combines the exploration of Higgs and top-quark physics, including a top threshold scan near 350 GeV. A higher-energy stage, still using the initial single drive-beam complex, can be optimised for any energy up to 2 TeV. Parameters are presented in detail for a 1.5 TeV stage, with a site length of 29 km. Since the 2018 ESPPU reporting, significant effort was invested in CLIC accelerator optimisation, technology developments and system tests, including collaboration with new-generation light sources and free-electron lasers. CLIC implementation aspects at CERN have covered detailed studies of civil engineering, electrical networks, cooling and ventilation, scheduling, and costing. The CLIC baseline at 380 GeV is now 100 Hz operation, with a luminosity of 4.5$\times 10^{34}$ cm$^{-2}$s$^{-1}$ and a power consumption of 166 MW. Compared to the 2018 design, this gives three times higher luminosity-per-power. The new baseline has two beam-delivery systems, allowing for two detectors operating in parallel. The cost estimate of the 380 GeV baseline is approximately 7.2 billion CHF. The construction of the first CLIC energy stage could start as early as ~2034/35 with first beams following a decade later. This report summarises the CLIC project, its implementation and running scenarios, with emphasis on new developments and recent progress. It concludes with an update on the CLIC detector studies and on the physics potential in light of the improved accelerator performance.

physics.acc-ph

Annealing behaviour of charge collection of neutron irradiated diodes from 8-inch p-type silicon wafers

To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL) concept. The electromagnetic section as well as the high-radiation regions of the hadronic section of the CE will be equipped with silicon pad sensors, covering a total area of 620 $\rm m^2$. Fluences up to $\rm1.0\cdot10^{16}~n_{eq}/cm^{2}$ and doses up to 2 MGy are expected considering an integrated luminosity of 3 $\rm ab^{-1}$. The whole CE will normally operate at -35{\deg}C in order to mitigate the effects of radiation damage. The silicon sensors are processed on novel 8-inch p-type wafers with an active thickness of 300 $\mu m$, 200 $\mu m$ and 120 $\mu m$ and cut into hexagonal shapes for optimal use of the wafer area and tiling. With each main sensor several small sized test structures (e.g pad diodes) are hosted on the wafers, used for quality assurance and radiation hardness tests. In order to investigate the radiation-induced bulk damage, these diodes have been irradiated with reactor neutrons at the TRIGA reactor in JSI (Jo\v{z}ef Stefan Institute, Ljubljana) to 13 fluences between $\rm6.5\cdot10^{14}~n_{eq}/cm^{2}$ and $\rm1.5\cdot10^{16}~n_{eq}/cm^{2}$. The charge collection of the irradiated silicon diodes was determined through transient current technique (TCT) measurements. The study focuses on the isothermal annealing behaviour of the bulk material at 60{\deg}C. The results have been used to extend the usage of thicker silicon sensors in regions expecting higher fluences and are being used to estimate the expected annealing effects of the silicon sensors during year-end technical stops and long HL-LHC shutdowns currently foreseen with a temperature around 0{\deg}C.

physics.ins-det

Isothermal annealing of radiation defects in bulk material of diodes from 8" silicon wafers

The high luminosity upgrade of the LHC will provide unique physics opportunities, such as the observation of rare processes and precision measurements. However, the accompanying harsh radiation environment will also pose unprecedented challenged to the detector performance and hardware. In this paper, we study the radiation induced damage and its macroscopic isothermal annealing behaviour of the bulk material from new 8" silicon wafers using diode test structures. The sensor properties are determined through measurements of the diode capacitance and leakage current for three thicknesses, two material types, and neutron fluences from $6.5\cdot 10^{14}$ to $10^{16}\,\mathrm{neq/cm^2}$.

physics.ins-det

ARRAY: An Open Source, Modular and Probe-Card based System with Integrated Switching Matrix for Characterisation of Large Area Silicon Pad Sensors

Silicon pad sensors are proposed as active material in highly granular sampling calorimeters of future collider experiments such as the Compact Linear Collider (CLIC) or the International Linear Collider (ILC). The electromagnetic section of these designs often include O(1000 m$^2$) of silicon pad sensors. For the luminosity measurement, a dedicated forward calorimeter called LumiCal is foreseen. More recently, the CMS experiment has decided to adopt the same concept in its endcap calorimeter upgrade for the HL-LHC. The sensors are typically produced from 6- or 8-inch wafers and consist of a few hundred smaller cells, each with an area of O(0.1 to 1 $\text{cm}^2$). For the prototyping phase of these projects, several design choices have to be evaluated while for mass production, thousands of sensors have to be tested for quality control. For the electrical characterisation of these sensors, it is important to bias them under realistic conditions. To fulfil these requirements, ARRAY, a compact, modular and cost efficient system for large area silicon pad sensor characterisation has been developed and successfully commissioned. It consists of two plugin printed circuit boards: an active switching matrix with 512 input channels that holds all controls and a passive probe card that connects to the sensor. The latter can then be adapted to any sensor geometry. All design files are open source. The system has been used to measure currents ranging from 500 pA to 5 $μ$A and capacitances between 5 pF and 100 pF. A precision of better than 0.2 pF on capacitance measurements in that range can be achieved. Examples of calibration and measurement results for leakage current and capacitance are presented.

physics.ins-det

From precision physics to the energy frontier with the Compact Linear Collider

The Compact Linear Collider (CLIC) is a proposed high-luminosity collider that would collide electrons with their antiparticles, positrons, at energies ranging from a few hundred Giga-electronvolts (GeV) to a few Tera-electronvolts (TeV). By covering a large energy range and by ultimately reaching multi-TeV $e^+e^-$ collisions, scientists at CLIC aim to improve the understanding of nature's fundamental building blocks and to discover new particles or other physics phenomena. CLIC is an international project with institutes world-wide participating in the accelerator, detector and physics studies. First $e^+e^-$ collisions at CLIC are expected around 2035, following the High-Luminosity phase of the Large Hadron Collider at CERN.

physics.acc-ph

Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013

This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.

hep-ex

Minimum Bias Measurements with ALICE at the LHC

ALICE (A Large Ion Collider Experiment) is one of the seven experiments at the the Large Hadron Collider (LHC) at CERN, Geneva, Switzerland. ALICE is especially designed for heavy-ion collisions but it also operates a rich proton-proton (pp) program. ALICE has collected pp collision data at $\sqrt{s}=$ 0.9, 2.36, 2.76, and 7 TeV and lead-lead (Pb--Pb) collision data at $\sqrt{s_{\mathrm{NN}}}=$2.76 TeV. Here, we report minimum bias measurements obtained until the end of 2010: the results include measurements of charged-particle pseudorapidity, multiplicity and transverse momentum distributions. Also, the two-pion Bose-Einstein correlation and the measurement of antiproton-to-proton ratio will be discussed. Furthermore, results on the production of identified particles including strange particles will be shown as well as first results from the first Pb--Pb run at the LHC.

hep-ex

Multiplicity Dependence of Two-Particle Correlations in Proton-Proton Collisions Measured with ALICE at the LHC

We investigate properties of jets in proton-proton collisions using two-particle angular correlations. By choosing an analysis approach based on two-particle angular correlations, also the properties of low-energetic jets can be accessed. Observing the strength of the correlation as a function of the charged particle multiplicity reveals jet fragmentation properties as well as the contribution of jets to the overall charged particle multiplicity. Furthermore, the analysis discloses information on the underlying multiple parton interactions. We present results from proton-proton collisions at the center-of-mass energies $\sqrt{s}$ = 0.9, 2.76, and 7.0 TeV recorded by the ALICE experiment. The ALICE data are compared to Pythia6, Pythia8, and Phojet simulations.

hep-ex