Ewa Ł. Stępień

Publications and source records attributed to Ewa Ł. Stępień.

8 recordsLinked to original sources

First Positronium Lifetime Imaging using $^{52}$Mn and $^{55}$Co with a plastic-based PET scanner

Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. In this work, we report the first PLI measurements performed with $^{52}$Mn and $^{55}$Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511~keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime $τ_{\text{oPs}}$ and the mean positron lifetime $ΔT_{\text{mean}}$ for each sample. The measured values of $τ_{\text{oPs}}$ in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, $^{55}$Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with $^{52}$Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced $τ_{\text{oPs}}$ values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, $^{55}$Co provides cleaner PLI data under the same experimental conditions. Although $^{52}$Mn offers a longer half-life and a multi gamma cascade enhancing $β^{+}$ + $γ$ coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns.

physics.med-ph↗

First ex-vivo positronium imaging of tissues with modular J-PET scanner using $^{44}$Sc radionuclide

This study presents the first ex-vivo positronium imaging of human tissues using the modular J-PET scanner with the $^{44}$Sc radionuclide. The $^{44}$Sc isotope was produced via the $^{44}$Ca(p, n)$^{44}$Sc nuclear reaction and used to perform positronium imaging of phantom composed of human adipose tissue, cardiac myxoma tissue, thrombi blood clot, and also porous polymer XAD4, and a certified reference material (CRM) made from fused silica. The experiment demonstrates the suitability of $^{44}$Sc as a positron source for positronium imaging. The performance of J-PET for positronium imaging with $^{44}$Sc was validated by proper reconstruction of the mean orthopositronium lifetime for CRM material and XAD-4 polymer. The mean ortho-positronium (oPs) lifetimes determined for adipose tissue, cardiac myxoma tissues and thrombi were consistent with results of previous experiments. The study highlights the potential $^{44}$Sc radionuclide for positronium lifetime imaging (PLI).

physics.med-ph↗

First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.

physics.med-ph↗

First Positronium Lifetime Imaging with Scandium-44 on a Long Axial Field-of-view PET/CT

Purpose: 44Sc has been successfully produced, synthesized, labeled and first-in-human studies were conducted some years ago. The decay properties of 44Sc, together with being close to a clinical implementation, make it an ideal candidate for in vivo positronium lifetime measurements. In this study, we investigate the count statistics for ortho-positronium (oPs) measurements with 44Sc. Method: A NEMA image quality phantom was filled with 41.7 MBq of 44Sc dissolved in water and scanned on a commercial long-axial field-of-view PET/CT. Three-photon events were identified using a prototype feature of the scanner and dedicated software. The lifetime of oPs was determined in the phantom spheres and in 4x4x4 mm^3 voxels. Results: All measured oPs lifetimes are compatible, within the uncertainties, with the literature values for water. The oPs lifetime is 2.65+-0.50, 1.39+-0.20 and 1.76+-0.18 ns in the three smallest spheres of the phantom and 1.79+-0.57 ns for a single voxel in the central region of the largest sphere. The relative standard deviation in the background regions of the time difference distributions, i.e., for time differences smaller than -2.7 ns, is above 20% - even for voxels inside the phantom spheres. Conclusions: Despite the favorable physical properties of 44Sc, the count statistics of three-photon events remains a challenge. The high prompt-photon energy causes a significant amount of random three-photon coincidences with the given methodology and, therefore, increases the statistical uncertainties on the measured oPs lifetime.

physics.med-ph↗

Positronium Lifetime Imaging with the Biograph Vision Quadra using 124I

Purpose: Measuring the ortho-positronium (oPs) lifetime in human tissue bears the potential of adding clinically relevant information about the tissue microenvironment to conventional positron emission tomography (PET). Through phantom measurements, we investigate the voxel-wise measurement of oPs lifetime using a commercial long-axial field-of-view (LAFOV) PET scanner. Methods: We prepared four samples with mixtures of Amberlite XAD4, a porous polymeric adsorbent, and water and added between 1.12 MBq and 1.44 MBq of $^{124}$I. The samples were scanned in two different setups: once with a couple of centimeters between each sample (15 minutes scan time) and once with all samples taped together (40 minutes scan time). For each scan, we determine the oPs lifetime for the full samples and at the voxel level. The voxel sizes under consideration are $10.0^3$ mm$^3$, $7.1^3$ mm$^3$ and $4.0^3$ mm$^3$. Results: Amberlite XAD4 allows the preparation of samples with distinct oPs lifetime. Using a Bayesian fitting procedure, the oPs lifetimes in the whole samples are $2.52 \pm 0.03$ ns, $2.37\pm 0.03$ ns, $2.27\pm0.04$ ns and $1.82\pm 0.02$ ns, respectively. The voxel-wise oPs lifetime fits showed that even with $4.0^3$ mm$^3$ voxels the samples are clearly distinguishable and a central voxels have good count statistics. However, the situation with the samples close together remains challenging with respect to the spatial distinction of regions with different oPs lifetimes. Conclusion: Our study shows that positronium lifetime imaging on a commercial LAFOV PET/CT should be feasible under clinical conditions using $^{124}$I.

physics.med-ph↗

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph↗

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph↗

Positronium imaging with the novel multiphoton PET scanner

In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.

physics.med-ph↗