SearcharxivSearch

arXiv subjects

F. Ardellier

Publications and source records attributed to F. Ardellier.

3 recordsLinked to original sources

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment

The Double Chooz Experiment presents an indication of reactor electron antineutrino disappearance consistent with neutrino oscillations. A ratio of 0.944 $\pm$ 0.016 (stat) $\pm$ 0.040 (syst) observed to predicted events was obtained in 101 days of running at the Chooz Nuclear Power Plant in France, with two 4.25 GW$_{th}$ reactors. The results were obtained from a single 10 m$^3$ fiducial volume detector located 1050 m from the two reactor cores. The reactor antineutrino flux prediction used the Bugey4 measurement as an anchor point. The deficit can be interpreted as an indication of a non-zero value of the still unmeasured neutrino mixing parameter \sang. Analyzing both the rate of the prompt positrons and their energy spectrum we find \sang = 0.086 $\pm$ 0.041 (stat) $\pm$ 0.030 (syst), or, at 90% CL, 0.015 $<$ \sang $\ <$ 0.16.

hep-ex

Letter of Intent for Double-CHOOZ: a Search for the Mixing Angle Theta13

Tremendous progress has been achieved in neutrino oscillation physics during the last few years. However, the smallness of the $\t13$ neutrino mixing angle still remains enigmatic. The current best constraint comes from the CHOOZ reactor neutrino experiment $\s2t13 < 0.2$ (at 90% C.L., for $\adm2=2.0 10^{-3} \text{eV}^2$). We propose a new experiment on the same site, Double-CHOOZ, to explore the range of $\s2t13$ from 0.2 to 0.03, within three years of data taking. The improvement of the CHOOZ result requires an increase in the statistics, a reduction of the systematic error below one percent, and a careful control of the cosmic ray induced background. Therefore, Double-CHOOZ will use two identical detectors, one at $\sim$150 m and another at 1.05 km distance from the nuclear cores. The plan is to start data taking with two detectors in 2008, and to reach a sensitivity of 0.05 in 2009, and 0.03 in 2011.

hep-ex