SearcharxivSearch

arXiv subjects

F. Bosi

Publications and source records attributed to F. Bosi.

12 recordsLinked to original sources

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 from 2032 to 2034. The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors.

physics.ins-det

Application of exhaustive simulation flow for advanced performance prediction of monolithic active pixel sensors

Monolithic active pixel sensor (MAPS) developments have pushed the detection performance in various directions, especially relative to timing where nanosecond-level precision is now considered. This evolution calls for a simultaneous upgrade of the simulation tools. We have developed a simulation flow that covers steps from the signal creation in the sensitive volume to the output of the pixel digital logic that performs the time-of-arrival and time-over-threshold (ToA/ToT) measurements. This approach adds several new features to the traditional use the of the TCAD - Allpix Squared duo, among which : the integration of the pixel wells from the layout in order to precisely describe the pixel key characteristics such as leakage and punch-through currents and the coupling of Monte Carlo simulations (Allpix Squared) with high precision electrical simulations (SPICE). The first (Allpix Squared) for the precise description of the current induced at the collection electrode and the second (SPICE) to guarantee high precision simulation of the front-end electronics using realistic signal events. Irradiation is also modeled, both from the charge propagation side (charge trapping) and from the front-end response side (high input signal discharge). We have applied this methodology to the MAPS developed in the context of the Belle II vertex detector upgrade. In this contribution, we detail the key features of the exhaustive simulation flow, present the outcome of the comparison with the TJ-Monopix2 measurements and discuss the interest of the methodology for the development of modern MAPS.

physics.ins-det

The Belle II Detector Upgrades Framework Conceptual Design Report

We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.

hep-ex

Upgrade of Belle II Vertex Detector with CMOS Pixel Technology

The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MAPS chips to improve background robustness and reduce occupancy levels through small and fast pixels. This causes better track finding, especially for low transverse momenta tracks. This text will focus on the predecessor of the OBELIX sensor, the TJ-Monopix2, presenting laboratory and test beam results on pixel response, efficiency, and spatial resolution.

physics.ins-det

Asymptotic self-restabilization of a continuous elastic structure

A challenge in soft robotics and soft actuation is the determination of an elastic system which spontaneously recovers its trivial path during postcritical deformation after a bifurcation. The interest in this behaviour is that a displacement component spontaneously cycles around a null value, thus producing a cyclic soft mechanism. An example of such a system is theoretically proven through the solution of the Elastica and a stability analysis based on dynamic perturbations. It is shown that the asymptotic self-restabilization is driven by the development of a configurational force, of similar nature to the Peach-Koehler interaction between dislocations in crystals, which is derived from the principle of least action. A proof-of-concept prototype of the discovered elastic system is designed, realized, and tested, showing that this innovative behaviour can be obtained in a real mechanical apparatus.

cond-mat.soft

First Results of GINGERino, a deep underground ringlaser

Large ring-laser gyroscopes are capable of measuring angular rotations with a precision well below fractions of $prad/s$, not far from $10^{-14}$ $rad/s$, the accuracy required for General Relativity tests, this is what the GINGER (Gyroscope-IN-GEneral-Relativity) experiment is aiming for. These features do not guarantee the possibility of measuring the General Relativity Lense--Thirring effect, that manifests itself as a tiny ($\approx 10^{-9} \times Ω_E$) perturbation of the Earth rotation rate. An underground location being in principle less affected by external local disturbances represents a good candidate for housing such a challenging experiment. GINGERino is a test apparatus to investigate the residual local disturbances in the most inner part of the underground international laboratory of the GranSasso (LNGS). It consists of a square ring laser with a $3.6$ m side. The instrument has been tailored to be the larger allowed by the particular location inside the laboratory. Its main objective is to measure the very low frequency rotational motions, in order to prove that LNGS is a suitable location for very low noise measurements and, possibly, General Relativity tests. Aside this main goal, GINGERino will provide unique data for geodesy and geophysics. Its installation has been completed during 2015. Since then, several long set of data have been collected, and the apparatus has been continuously running unattended for more than one week. The typical power spectrum sensitivity was a few $ 10^{-10} rad/s/\sqrt(Hz)$, with integration time not longer than tens of seconds. Improvements of the apparatus are ongoing in order to improve the integration time.

physics.ins-det

Development of configurational forces during the injection of an elastic rod

When an inextensible elastic rod is 'injected' through a sliding sleeve against a fixed constraint, configurational forces are developed, deeply influencing the mechanical response. This effect, which is a consequence of the change in length of the portion of the rod included between the sliding sleeve and the fixed constraint, is theoretically demonstrated (via integration of the elastica) and experimentally validated on a proof-of-concept structure (displaying an interesting force reversal in the load/deflection diagram), to provide conclusive evidence to mechanical phenomena relevant in several technologies, including guide wire for artery catheterization, or wellbore insertion of a steel pipe.

cond-mat.soft

An Elastica Arm Scale

The concept of 'deformable arm scale' (completely different from a traditional rigid arm balance) is theoretically introduced and experimentally validated. The idea is not intuitive, but is the result of nonlinear equilibrium kinematics of rods inducing configurational forces, so that deflection of the arms becomes necessary for the equilibrium, which would be impossible for a rigid system. In particular, the rigid arms of usual scales are replaced by a flexible elastic lamina, free of sliding in a frictionless and inclined sliding sleeve, which can reach a unique equilibrium configuration when two vertical dead loads are applied. Prototypes realized to demonstrate the feasibility of the system show a high accuracy in the measure of load within a certain range of use. It is finally shown that the presented results are strongly related to snaking of confined beams, with implications on locomotion of serpents, plumbing, and smart oil drilling.

physics.ins-det

A ring-lasers array for fundamental physics

After reviewing the importance of light as a probe for testing the structure of space-time, we describe the GINGER project. GINGER will be a three-dimensional array of large size ring-lasers able to measure the de Sitter and Lense-Thirring effects. The instrument will be located at the underground laboratory of GranSasso, in Italy. We describe the preliminary actions and measurements already under way and present the full road map to GINGER. The intermediate apparatuses GP2 and GINGERino are described. GINGER is expected to be fully operating in few years.

gr-qc

Experimental investigation of the elastoplastic response of aluminum silicate spray dried powder during cold compaction

Mechanical experiments have been designed and performed to investigate the elasto-plastic behaviour of green bodies formed from an aluminum silicate spray dried powder used for tiles production. Experiments have been executed on samples obtained from cold compaction into a cylindrical mould and include: uniaxial strain, equi-biaxial flexure and high-pressure triaxial compression/extension tests. Two types of powders have been used to realize the green body samples, differing in the values of water content, which have been taken equal to those usually employed in the industrial forming of traditional ceramics. Yielding of the green body during compaction has been characterized in terms of yield surface shape, failure envelope, and evolution of cohesion and void ratio with the forming pressure, confirming the validity of previously proposed constitutive models for dense materials obtained through cold compaction of granulates.

cond-mat.mtrl-sci

Measuring Gravito-magnetic Effects by Multi Ring-Laser Gyroscope

We propose an under-ground experiment to detect the general relativistic effects due to the curvature of space-time around the Earth (de Sitter effect) and to rotation of the planet (dragging of the inertial frames or Lense-Thirring effect). It is based on the comparison between the IERS value of the Earth rotation vector and corresponding measurements obtained by a tri-axial laser detector of rotation. The proposed detector consists of six large ring-lasers arranged along three orthogonal axes. In about two years of data taking, the 1% sensitivity required for the measurement of the Lense-Thirring drag can be reached with square rings of 6 $m$ side, assuming a shot noise limited sensitivity ($ 20 prad/s/\sqrt{Hz}$). The multi-gyros system, composed of rings whose planes are perpendicular to one or the other of three orthogonal axes, can be built in several ways. Here, we consider cubic and octahedron structures. The symmetries of the proposed configurations provide mathematical relations that can be used to study the stability of the scale factors, the relative orientations or the ring-laser planes, very important to get rid of systematics in long-term measurements, which are required in order to determine the relativistic effects.

gr-qc

A device to characterize optical fibres

ATLAS is a general purpose experiment approved for the LHC collider at CERN. An important component of the detector is the central hadronic calorimeter; for its construction more than 600,000 Wave Length Shifting (WLS) fibres (corresponding to a total length of 1,120 Km) have been used. We have built and put into operation a dedicated instrument for the measurement of light yield and attenuation length over groups of 20 fibres at a time. The overall accuracy achieved in the measurement of light yield (attenuation length) is 1.5% (3%). We also report the results obtained using this method in the quality control of a large sample of fibres.

hep-ex