SearcharxivSearch

arXiv subjects

F. Cavaliere

Publications and source records attributed to F. Cavaliere.

At least 19 recordsLinked to original sources

Quantum advantage bounds for a multipartite Gaussian battery

We demonstrate the possibility of a genuine quantum advantage in the efficiency of quantum batteries by analyzing a model that enables a consistent comparison between quantum and classical regimes. Our system consists of $N$ harmonic oscillator cells coupled to a common thermal reservoir, evolving through Gaussian states. We define the global efficiency as the ratio of extractable work (ergotropy) to stored energy, and derive analytical bounds that distinguish, in order of increasing efficiency, regimes characterized by classical squeezing, quantum squeezing without entanglement, and genuine entanglement. Moreover, numerical simulations support the emergence of a similar hierarchy for the thermodynamic efficiency, defined as the ratio between ergotropy and the total thermodynamic cost of the charging process.

quant-ph

Collisional charging of a transmon quantum battery

Motivated by recent developments in the field of multilevel quantum batteries, we present the model of a quantum device for energy storage with anharmonic level spacing, based on a superconducting circuit in the transmon regime. It is charged via the sequential interaction with a collection of identical and independent ancillary two-level systems. By means of a numerical analysis we show that, in case these ancillas are coherent, this kind of quantum battery can achieve remarkable performances for what it concerns the control of the stored energy and its extraction in regimes of parameters within reach in nowadays quantum circuits.

quant-ph

A chemically etched D-band waveguide orthomode transducer for CMB measurements

This study presents a prototype D-band waveguide orthomode transducer (OMT) fabricated using chemically etched brass platelets. This method offers a fast, cost-effective, and scalable approach for producing waveguide OMTs above 100 GHz, making it well-suited for current and future Cosmic Microwave Background polarization experiments, where large focal planes with thousands of receivers are required to detect the faint primordial \textit{B}-modes. Chemical etching has already demonstrated its effectiveness in manufacturing corrugated feedhorn arrays with state-of-the-art performance up to 150 GHz. Here, we evaluate its applicability to more complex structures, such as OMTs. We designed a single OMT prototype operating in the 130-170 GHz range, fabricated by chemically etching 0.15 mm-thick brass plates, which were then stacked, aligned, and mechanically clamped. Simulations based on metrological measurements of the OMT profile predict return losses below $-$10 dB, isolation better than $-$30 dB, and transmission around $-$0.5 dB. The measured transmission and isolation, however, is around $-$1.5/$-$2 dB and $<-$20 dB, respectively. Further simulations show that the degradation in the transmission is related to defects and roughness along the etched profile ($\mathrm{RMS}\simeq$3 $\mu$m), which is a typical and unavoidable effect of chemical etching. The discrepancy in isolation, instead, could arise from a slight rotation ($\sim$3$^{\circ}$) of the polarization angle within the measurement chain. Our results show that chemical etching is a fast, low-cost, and scalable technique for producing waveguide OMTs with state-of-the-art performance in terms of return loss and isolation. However, at frequencies above 100 GHz the transmission coefficient may degrade due to the mechanical precision limitations of chemical etching.

astro-ph.IM

Dynamical blockade of a reservoir for optimal performances of a quantum battery

The development of fast and efficient quantum batteries is crucial for the prospects of quantum technologies. We show that both requirements are accomplished in the paradigmatic model of a harmonic oscillator strongly coupled to a highly non-Markovian thermal reservoir. At short times, a dynamical blockade of the reservoir prevents the leakage of energy towards its degrees of freedom, promoting a significant accumulation of energy in the battery with high efficiency. The possibility of implementing these conditions in $LC$ quantum circuits opens up new avenues for solid-state quantum batteries.

quant-ph

Measuring the CMB primordial B-modes with Bolometric Interferometry

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of \Delta{\nu}/{\nu} \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.

astro-ph.CO

Status of QUBIC, the Q&U Bolometer for Cosmology

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematics with those of bolometric detectors in terms of wide-band, background-limited sensitivity.

astro-ph.IM

Total power horn-coupled 150 GHz LEKID array for space applications

We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated feed-horns, while the second is sensitive to the polarisation of the radiation thanks to orthomode transducers. Here, we focus on the total power detector array, which is suitable, for instance, for precision measurements of unpolarised spectral distortions of the CMB, where detecting both polarisations provides a sensitivity advantage. We describe the optimisation of the array design, fabrication and packaging, the dark and optical characterisation, and the performance of the black-body calibrator used for the optical tests. We show that almost all the detectors of the array are photon-noise limited under the radiative background of a 3.6 K black-body. This result, combined with the weak sensitivity to cosmic rays hits demonstrated with the OLIMPO flight, validates the idea of using lumped elements kinetic inductance detectors for precision, space-based CMB missions.

astro-ph.IM

QUBIC VII: The feedhorn-switch system of the technological demonstrator

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.

astro-ph.IM

QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

astro-ph.IM

QUBIC III: Laboratory Characterization

A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.

astro-ph.IM

The LSPE-Strip feed horn array

In this paper we discuss the design, manufacturing and characterization of the feed horn array of the Strip instrument of the Large Scale Polarization Explorer (LSPE) experiment. Strip is a microwave telescope, operating in the Q- and W-band, for the observation of the polarized emissions from the sky in a large fraction (about 37%) of the Northern hemisphere with subdegree angular resolution. The Strip focal plane is populated by forty-nine Q-band and six W-band corrugated horns, each feeding a cryogenically cooled polarimeter for the detection of the Stokes $Q$ and $U$ components of the polarized signal from the sky. The Q-band channel is designed to accurately monitor Galactic polarized synchrotron emission, while the combination of Q- and W-band will allow the study of atmospheric effects at the observation site, the Observatorio del Teide, in Tenerife. In this paper we focus on the development of the Strip corrugated feed horns, including design requirements, engineering and manufacturing, as well as detailed characterization and performance verification.

astro-ph.IM

QUBIC IV: Performance of TES Bolometers and Readout Electronics

A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.

astro-ph.IM

QUBIC I: Overview and ScienceProgram

The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.

astro-ph.IM

QUBIC V: Cryogenic system design and performance

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

astro-ph.IM

QUBIC VIII: Optical design and performance

The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.

astro-ph.IM

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.

astro-ph.IM

Nonintrusive reduced order model for parametric solutions of inertia relief problems

The Inertia Relief (IR) technique is widely used by industry and produces equilibrated loads allowing to analyze unconstrained systems without resorting to the more expensive full dynamic analysis. The main goal of this work is to develop a computational framework for the solution of unconstrained parametric structural problems with IR and the Proper Generalized Decomposition (PGD) method. First, the IR method is formulated in a parametric setting for both material and geometric parameters. A reduced order model using the encapsulated PGD suite is then developed to solve the parametric IR problem, circumventing the so-called curse of dimensionality. With just one offline computation, the proposed PGD-IR scheme provides a computational vademecum that contains all the possible solutions for a pre-defined range of the parameters. The proposed approach is nonintrusive and it is therefore possible to be integrated with commercial FE packages. The applicability and potential of the developed technique is shown using a three dimensional test case and a more complex industrial test case. The first example is used to highlight the numerical properties of the scheme, whereas the second example demonstrates the potential in a more complex setting and it shows the possibility to integrate the proposed framework within a commercial FE package. In addition, the last example shows the possibility to use the generalized solution in a multi-objective optimization setting.

math.NA

QUBIC VI: cryogenic half wave plate rotator, design and performances

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).

astro-ph.IM