SearcharxivSearch

arXiv subjects

F. D. Brooks

Publications and source records attributed to F. D. Brooks.

2 recordsLinked to original sources

A Compact High-Energy Neutron Spectrometer

A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for use in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.

physics.ins-det

Towards Earth AntineutRino TomograpHy (EARTH)

The programme Earth AntineutRino TomograpHy (EARTH) proposes to build ten underground facilities each hosting a telescope. Each telescope consists of many detector modules, to map the radiogenic heat sources deep in the interior of the Earth by utilising direction sensitive geoneutrino detection. Recent hypotheses target the core-mantle boundary (CMB) as a major source of natural radionuclides and therefore of radiogenic heat. A typical scale of the processes that take place at the CMB is about 200km. To observe these processes from the surface requires an angular resolution of about 3 degrees. EARTH aims at creating a high-resolution 3D-map of the radiogenic heat sources in the interior of the Earth. It will thereby contribute to a better understanding of a number of geophysical phenomena observed at the surface of the Earth. This condition requires a completely different approach from the monolithic detector systems as e.g. KamLAND. This paper presents, for such telescopes, the boundary conditions set by physics, the estimated count rates, and the first initial results from Monte Carlo simulations and laboratory experiments. The Monte Carlo simulations indicate that the large volume telescope should consist of detector modules each comprising a very large number of detector units, with a cross section of roughly a few square centimetres. The signature of an antineutrino event will be a double pulse event. One pulse arises from the slowing down of the emitted positron, the other from the neutron capture. In laboratory experiments small sized, 10B-loaded liquid scintillation detectors were investigated as candidates for direction sensitive, low-energy antineutrino detection.

physics.geo-ph