SearcharxivSearch

arXiv subjects

F. Fichera

Publications and source records attributed to F. Fichera.

5 recordsLinked to original sources

Sensor operating point calibration and monitoring of the ALICE Inner Tracking System during LHC Run 3

The new Inner Tracking System (ITS2) of the ALICE experiment began operation in 2021 with the start of LHC Run 3. Compared to its predecessor, ITS2 offers substantial improvements in pointing resolution, tracking efficiency at low transverse momenta, and readout-rate capabilities. The detector employs silicon Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 26.88$\times$29.24 $\mu$m$^2$ and an intrinsic spatial resolution of approximately 5 $\mu$m. With a remarkably low material budget of 0.36% of radiation length ($X_{0}$) per layer in the three innermost layers and a total sensitive area of about 10 m$^2$, the ITS2 constitutes the largest-scale application of MAPS technology in a high-energy physics experiment and the first of its kind operated at the LHC. For stable data taking, it is crucial to calibrate different parameters of the detector, such as in-pixel charge thresholds and the masking of noisy pixels. The calibration of 24120 monolithic sensors, comprising a total of 12.6$\times$10$^{9}$ pixels, represents a major operational challenge. This paper presents the methods developed for the calibration of the ITS2 and outlines the strategies for monitoring and dynamically adjusting the detector's key performance parameters over time.

physics.ins-det

Overhaul and Installation of the ICARUS-T600 Liquid Argon TPC Electronics for the FNAL Short Baseline Neutrino Program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

physics.ins-det

Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector

ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were also characterized at cryogenic temperature, in liquid argon bath, to evaluate any parameter variation which could affect the scintillation light detection. All the tested PMTs were found to comply with the requirements of ICARUS T600 and a subset of 360 specimens was selected for the final installation in the detector.

physics.ins-det

New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system

The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

physics.ins-det

Educational cosmic ray experiments with Geiger counters

Experiments concerning the physics of cosmic rays offer to high-school teachers and students a relatively easy approach to the field of research in high energy physics. The detection of cosmic rays does not necessarily require the use of sophisticated equipment, and various properties of the cosmic radiation can be observed and analysed even by the use of a single Geiger counter. Nevertheless, the variety of such kind of experiments and the results obtained are limited because of the inclusive nature of these measurements. A significant improvement may be obtained when two or more Geiger counters are operated in coincidence. In this paper we discuss the potential of performing educational cosmic ray experiments with Geiger counters. In order to show also the educational value of coincidence techniques, preliminary results of cosmic ray experiments carried out by the use of a simple coincidence circuit are briefly discussed.

physics.ed-ph