Searcharxiv⌕ Search

arXiv subjects

F. Garcia

Publications and source records attributed to F. Garcia.

At least 37 records · Page 2Linked to original sources

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det↗

Timing irregularities and glitches from the pulsar monitoring campaign at IAR

Context. Pulsars have a very stable rotation. However, sudden increases in their rotation frequency known as glitches, perturb their evolution. While large glitches are commonly detected, small glitches are harder to detect because of the lack of daily-cadence observations over long periods of time. Aims. We aim to explore the timing behaviour of young pulsars at daily timescales looking for small glitches and other irregularities. This will further our comprehension of the distribution of glitch sizes, which has also consequences for the theoretical modeling of the glitch mechanism. Methods. We observed six pulsars with up to daily cadence during 5 years with the antennas of the Argentine Institute of Radio Astronomy (IAR). We used standard pulsar timing tools to characterise the rotation of pulsars and developed an algorithm to look for small timing events in the data and calculate the changes in $ν$ and $\dotν$ at those epochs. Results. We found that the rotation of pulsars in this dataset is affected by small step changes in $ν$ and $\dotν$. We found three glitches that had not been reported before: two in PSR J1048-5832 with relative sizes $Δν/ ν= 9.1(4) \times 10^{-10}$ and $Δν/ ν= 4.5(1) \times 10^{-10}$, and one in the Vela pulsar with a size $Δν/ ν= 2.0(2) \times 10^{-10}$. We also report new decay terms on the 2021 Vela giant glitch, and on the 2022 giant glitches in PSR J0742-2822 and PSR J1740-3015 respectively. Besides, we found that the red noise contribution significantly diminished in PSR J0742-2822 after its giant glitch in 2022. Conclusions. Our results highlight the importance of high-cadence monitoring with an exhaustive analysis of the residuals to better characterize the distribution of glitch sizes and to deepen our understanding of the mechanisms behind glitches, red noise and timing irregularities.

astro-ph.HE↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det↗

Spatial resolution improvements with finer-pitch GEMs

Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.

physics.ins-det↗

Characterisation of resistive MPGDs with 2D readout

Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.

physics.ins-det↗

Pulsar Observations at low latitudes and low frequencies

The Pulsar Monitoring in Argentina (PuMA) is a collaboration between the Argentine Institute for Radioastronomy (IAR) and the Rochester Institute of Technology (RIT) that since 2017 has been observing southern sky pulsars with high cadence using the two restored IAR antennas in the L-Band (1400MHz). We briefly review the first set of results of this program to study transient phenomena, such as magnetars and glitching pulsars, as well as to perform precise timing of millisecond pulsars. Access to lower frequency bands, where most of the pulsars are brighter, would allow us to reach additional pulsars, currently buried into the background noise. We identify two dozen additional glitching pulsars that could be observable in the 400MHz band by the IAR's projected Multipurpose Interferometer Array (MIA). We also discuss the relevance and challenges of single-pulse pulsar timing at low frequencies and the search for Fast Radio Burst (FRB) in the collected data since 2017 using machine learning techniques.

astro-ph.IM↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.

hep-ex↗

The novel XYU-GEM to resolve ambiguities

Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45°. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.

physics.ins-det↗

Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates

The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.

physics.ins-det↗

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det↗

Host galaxy magnitude of OJ 287 from its colours at minimum light

OJ 287 is a BL Lacertae type quasar in which the active galactic nucleus (AGN) outshines the host galaxy by an order of magnitude. The only exception to this may be at minimum light when the AGN activity is so low that the host galaxy may make quite a considerable contribution to the photometric intensity of the source. Such a dip or a fade in the intensity of OJ 287 occurred in November 2017, when its brightness was about 1.75 magnitudes lower than the recent mean level. We compare the observations of this fade with similar fades in OJ 287 observed earlier in 1989, 1999, and 2010. It appears that there is a relatively strong reddening of the B$-$V colours of OJ 287 when its V-band brightness drops below magnitude 17. Similar changes are also seen V$-$R, V$-$I, and R$-$I colours during these deep fades. These data support the conclusion that the total magnitude of the host galaxy is $V=18.0 \pm 0.3$, corresponding to $M_{K}=-26.5 \pm 0.3$ in the K-band. This is in agreement with the results, obtained using the integrated surface brightness method, from recent surface photometry of the host. These results should encourage us to use the colour separation method also in other host galaxies with strongly variable AGN nuclei. In the case of OJ 287, both the host galaxy and its central black hole are among the biggest known, and its position in the black hole mass-galaxy mass diagram lies close to the mean correlation.

astro-ph.GA↗

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det↗

Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System

The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.

physics.ins-det↗

Overt and covert paths for sound in the auditory system of mammals. 2

Current scientific consensus holds that sound is transmitted, solely mechanically, from the tympanum to the cochlea via ossicles. However this theory does not explain the hearing extreme quality regarding high frequencies in mammals. So, we propose a bioelectronic pathway (the covert path) that is complementary to the overt path. We demonstrate experimentally that the tympanum produces piezoelectric potentials isochronous to acoustic vibrations thanks to its collagen fibers and that their amplitude increases along with the frequency and level of the vibrations. This finding supports the existence of an electrical pathway, specialized in transmitting high-frequency sounds that works in unison with the mechanical pathway. A bio-organic triode, similar to a field effect transistor, is the key mechanism of our hypothesized pathway. We present evidence that any deficiency along this pathway produces hearing impairment. By augmenting the classical theory of sound transmission, our discovery offers new perspectives for research into both normal and pathological audition and may contribute to an understanding of genetic and physiological problems of hearing.

q-bio.TO↗

Characterisation of the dip-bump structure observed in proton-proton elastic scattering at $\sqrt s$ = 8 TeV

The TOTEM collaboration at the CERN LHC has measured the differential cross-section of elastic proton-proton scattering at $\sqrt{s} = 8\ {\rm TeV}$ in the squared four-momentum transfer range $0.2\ {\rm GeV^{2}} < |t| < 1.9\ {\rm GeV^{2}}$. This interval includes the structure with a diffractive minimum ("dip") and a secondary maximum ("bump") that has also been observed at all other LHC energies, where measurements were made. A detailed characterisation of this structure for $\sqrt{s} = 8\ {\rm TeV}$ yields the positions, $|t|_{\rm dip} = (0.521 \pm 0.007)\ {\rm GeV^2}$ and $|t|_{\rm bump} = (0.695 \pm 0.026)\ {\rm GeV^2}$, as well as the cross-section values, ${{\rm d}σ/{\rm d} t}_{\rm dip} = (15.1 \pm 2.5)\ {\rm{μb/GeV^2}}$ and ${{\rm d}σ/{\rm d} t}_{\rm bump} = (29.7 \pm 1.8)\ {\rm{μb/GeV^2}}$, for the dip and the bump, respectively.

hep-ex↗

NICER uncovers the transient nature of the type-B quasi-periodic oscillation in the black hole candidate MAXI J1348-630

We present a systematic spectral-timing analysis of a fast appearance/disappearance of a type-B quasi-periodic oscillation (QPO), observed in four NICER observations of MAXI J1348-630. By comparing the spectra of the period with and without the type-B QPO, we found that the main difference appears at energy bands above ~2 keV, suggesting that the QPO emission is dominated by the hard Comptonised component. During the transition, a change in the relative contribution of the disk and Comptonised emission was observed. The disk flux decreased while the Comptonised flux increased from non-QPO to type-B QPO. However, the total flux did not change too much in the NICER band. Our results reveal that the type-B QPO is associated with a redistribution of accretion power between the disk and Comptonised emission. When the type-B QPO appears, more accretion power is dissipated into the Comptonised region than in the disk. Our spectral fits give a hint that the increased Comptonised emission may come from an additional component that is related to the base of the jet.

astro-ph.HE↗

Optical Readout Studies of the Thick-COBRA Gaseous Detector

The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The preservation of spatial information from the initial ionizations was demonstrated by analyzing the light emission from 5.9keV X-rays of an 55Fe source. The observed non-uniformity of the scintillation light from the holes supports the claim of a space localization accuracy better than the pitch of the holes. The acquired images were used to identify weak points and sources of instabilities in view of the development of new optimized structures.

physics.ins-det↗

A phenomenological model for the spontaneous exchange bias effect

In this work we propose an alternative model to explain the spontaneous exchange bias (SEB) effect observed in spin glass (SG)-like systems. As in a previously proposed model (Ref. 1), it is based on the unconventional dynamics of the SG-like moments at the magnetic hysteresis cycle. However, using a reliable estimate of the amount of SG-spins that are relaxing during the cycle, the new model can correctly describe the changes in the SEB observed for measurements performed at different temperatures and different maximum applied fields.

cond-mat.mtrl-sci↗