SearcharxivSearch

arXiv subjects

F. Gatti

Publications and source records attributed to F. Gatti.

At least 19 recordsLinked to original sources

Towards Low-Energy Electron High-Resolution Spectroscopy with Transition-Edge Sensors

We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a critical temperature of $\sim$ 80 mK. The electron source is based on vertically-aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the (92 - 99) eV kinetic energy range, we obtain a Gaussian energy resolution for fully-absorbed electrons of (0.479 $\pm$ 0.041 $\pm$ 0.055) eV. When considering the full-width at half-maximum of the peak, the corresponding resolution is of (1.44 $\pm$ 0.17 $\pm$ 0.27) eV. The former represents an improvement of (46 - 60)% with respect to previous results, and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 20, and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

physics.ins-det

Ultra-high precision high voltage system for PTOLEMY

The PTOLEMY project is prototyping a novel electromagnetic filter for high-precision $\beta$ spectroscopy, with the ultimate and ambitious long-term goal of detecting the cosmic neutrino background through electron capture on tritium bound to graphene. Intermediate small-scale prototypes can achieve competitive sensitivity to the effective neutrino mass, even with reduced energy resolution. To reach an energy resolution better than \SI{500}{meV} at the tritium $\beta$-spectrum endpoint of \SI{18.6}{keV}, and accounting for all uncertainties in the filtering chain, the electrode voltage must be controlled at the level of a few parts per million and monitored in real time. In this work, we present the first results obtained in this effort, using a chain of commercial ultra-high-precision voltage references, read out by precision multimeters and a \emph{field mill} device. The currently available precision on high voltage is, in the conservative case, as low as \SI{0.2}{ppm} per \SI{1}{kV} single board and $\lesssim$ \SI{50}{mV} over the \SI{10}{kV} series, presently limited by field mill read-out noise. However, assuming uncorrelated Gaussian noise extrapolation, the real precision could in principle be as low as \SI{0.05}{ppm} over \SI{20}{kV}.

physics.ins-det

Phenomenological Modeling of the $^{163}$Ho Calorimetric Electron Capture Spectrum from the HOLMES Experiment

We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of $^{163}$Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing $^{163}$Ho, supporting both data analysis and experimental design.

nucl-ex

New limit on the \mu+->e+\gamma decay with the MEG II experiment

This letter reports the result of the search for the decay \mu+->e+\gamma undertaken at the Paul Scherrer Institut in Switzerland with the MEG II experiment using the data collected in the 2021- 2022 physics runs. The sensitivity of this search is 2.2x10-13, a factor of 2.4 better than that of the full MEG dataset and obtained in a data taking period of about one fourth that of MEG, thanks to the superior performances of the new detector. The result is consistent with the expected background, yielding an upper limit on the branching ratio of B(\mu+->e+\gamma)<1.5 x 10-13 (90 % C.L.). Additional improvements are expected with the data collected during the years 2023-2024. The data-taking will continue in the coming years.

hep-ex

A Demonstration of Slowed Electron ${\bf E} \times {\bf B}$ Drift for PTOLEMY

To resolve the effective neutrino mass $m_\beta$ with an energy resolution of 50~meV, the PTOLEMY experiment has proposed a novel transverse electromagnetic filtering process. Substantially reducing the kinetic energy of tritium $\beta$-decay electrons by counteracting motion from ${\bf E}$ $\times$ ${\bf B}$ and $\nabla{\rm B}$ drift, the PTOLEMY filter requires an input of emitted electron kinematic information to generate a tailored, suitable electric field for each candidate. The collaboration proposes to extract these quantities by using antennae to observe the relativistic frequency shift of emitted cyclotron radiation as an electron transits by ${\bf E}$ $\times$ ${\bf B}$ drift through a uniform magnetic field region preceding the filter. Electrons must be contained within this region long enough such that an adequate integrated radiated power signal is received to accurately estimate these kinematics. This necessitates a controlled, slowed drift speed. This paper presents the experimental design to vary ${\bf E}$ $\times$ ${\bf B}$ drift speed of carbon-14 $\beta$-decay electrons using a custom electrode field cage situated between the pole faces of an electromagnet. Matching our results with high-fidelity simulation, we deduce a capacity to increase particle time of flight by a factor of 5 in the field cage's slow drift region. Limited only by the dimensions of our system, we assert drift speed can be arbitrarily slowed to meet the needs of PTOLEMY's future detector. Actualizing such a system is a crucial milestone in developing the detector, enabling future cyclotron radiation measurements, filter implementation, and source injection.

physics.ins-det

Most stringent bound on electron neutrino mass obtained with a scalable low temperature microcalorimeter array

The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the Standard Model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. In this Letter, we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of $^{163}$Ho. The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of $7\times10^7$ decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of $m_{\beta}<27$ eV/c$^2$ at 90% credibility. These results validate the feasibility of $^{163}$Ho calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.

hep-ex

Search for the X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be}$ processes with the MEG II detector

The observation of a resonance structure in the opening angle of the electron-positron pairs in the $^{7}$Li(p,\ee) $^{8}$Be reaction was claimed and interpreted as the production and subsequent decay of a hypothetical particle (X17). Similar excesses, consistent with this particle, were later observed in processes involving $^{4}$He and $^{12}$C nuclei with the same experimental technique. The MEG II apparatus at PSI, designed to search for the $\mu^+ \rightarrow \mathrm{e}^+ \gamma$ decay, can be exploited to investigate the existence of this particle and study its nature. Protons from a Cockroft-Walton accelerator, with an energy up to 1.1 MeV, were delivered on a dedicated Li-based target. The $\gamma$ and the e$^{+}$e$^{-}$ pair emerging from the $^8\mathrm{Be}^*$ transitions were studied with calorimeters and a spectrometer, featuring a broader angular acceptance than previous experiments. We present in this paper the analysis of a four-week data-taking in 2023 with a beam energy of 1080 keV, resulting in the excitation of two different resonances with Q-value \SI{17.6}{\mega\electronvolt} and \SI{18.1}{\mega\electronvolt}. No significant signal was found, and limits at \SI{90}{\percent} C.L. on the branching ratios (relative to the $\gamma$ emission) of the two resonances to X17 were set, $R_{17.6} < 1.8 \times 10^{-6} $ and $R_{18.1} < 1.2 \times 10^{-5} $.

nucl-ex

The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection

We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55Fe (6 keV line) and 241Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.

astro-ph.IM

A search for $\mu^+\to e^+\gamma$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $\mu^+\to e^+\gamma$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($\mu^+\to e^+\gamma$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($\mu^+\to e^+\gamma$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

Heisenberg's uncertainty principle in the PTOLEMY project: a theory update

We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $β$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.

hep-ph

ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.

astro-ph.IM

Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.

physics.ins-det

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.

astro-ph.IM

Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions

physics.ins-det

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series

This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Φ_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.

physics.ins-det

Progress report on the Large Scale Polarization Explorer

The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.

astro-ph.IM