SearcharxivSearch

arXiv subjects

F. Giacomini

Publications and source records attributed to F. Giacomini.

8 recordsLinked to original sources

Performance of the image persistence model for Euclid infrared detectors

Large-format infrared detectors are at the heart of major ground and space-based astronomical instruments, and the HgCdTe HxRG is the most widely used. The Near Infrared Spectrometer and Photometer (NISP) of the ESA's Euclid mission launched in July 2023 hosts 16 H2RG detectors in the focal plane. Their performance relies heavily on the effect of image persistence, which results in residual images that can remain in the detector for a long time contaminating any subsequent observations. Deriving a precise model of image persistence is challenging due to the sensitivity of this effect to observation history going back hours or even days. Nevertheless, persistence removal is a critical part of image processing because it limits the accuracy of the derived cosmological parameters. We will present the empirical model of image persistence derived from ground characterization data, adapted to the Euclid observation sequence and compared with the data obtained during the in-orbit calibrations of the satellite.

astro-ph.IM

Euclid. III. The NISP Instrument

The Near-Infrared Spectrometer and Photometer (NISP) on board the Euclid satellite provides multiband photometry and R>=450 slitless grism spectroscopy in the 950-2020nm wavelength range. In this reference article we illuminate the background of NISP's functional and calibration requirements, describe the instrument's integral components, and provide all its key properties. We also sketch the processes needed to understand how NISP operates and is calibrated, and its technical potentials and limitations. Links to articles providing more details and technical background are included. NISP's 16 HAWAII-2RG (H2RG) detectors with a plate scale of 0.3" pix^-1 deliver a field-of-view of 0.57deg^2. In photo mode, NISP reaches a limiting magnitude of ~24.5AB mag in three photometric exposures of about 100s exposure time, for point sources and with a signal-to-noise ratio (SNR) of 5. For spectroscopy, NISP's point-source sensitivity is a SNR = 3.5 detection of an emission line with flux ~2x10^-16erg/s/cm^2 integrated over two resolution elements of 13.4A, in 3x560s grism exposures at 1.6 mu (redshifted Ha). Our calibration includes on-ground and in-flight characterisation and monitoring of detector baseline, dark current, non-linearity, and sensitivity, to guarantee a relative photometric accuracy of better than 1.5%, and relative spectrophotometry to better than 0.7%. The wavelength calibration must be better than 5A. NISP is the state-of-the-art instrument in the NIR for all science beyond small areas available from HST and JWST - and an enormous advance due to its combination of field size and high throughput of telescope and instrument. During Euclid's 6-year survey covering 14000 deg^2 of extragalactic sky, NISP will be the backbone for determining distances of more than a billion galaxies. Its NIR data will become a rich reference imaging and spectroscopy data set for the coming decades.

astro-ph.IM

Riptide: a proton-recoil track imaging detector for fast neutrons

Riptide is a detector concept aiming to track fast neutrons. It is based on neutron--proton elastic collisions inside a plastic scintillator, where the neutron momentum can be measured by imaging the scintillation light. More specifically, by stereoscopically imaging the recoil proton tracks, the proposed apparatus provides neutron spectrometry capability and enable the online analysis of the specific energy loss along the track. In principle, the spatial and topological event reconstruction enables particle discrimination, which is a crucial property for neutron detectors. In this contribution, we report the advances on the Riptide detector concept. In particular, we have developed a Geant4 optical simulation to demonstrate the possibility of reconstructing with sufficient precision the tracks and the vertices of neutron interactions inside a plastic scintillator. To realistically model the optics of the scintillation detector, mono-energetic protons were generated inside a $6\times6\times6$ cm$^3$ cubic BC-408 scintillator, and the produced optical photons were propagated and then recorded on a scoring plane corresponding to the surfaces of the cube. The photons were then transported through an optical system to a $2\times2$ cm$^2$ photo sensitive area with 1 Megapixel. Moreover, we have developed two different analysis procedures to reconstruct 3D tracks: one based on data fitting and one on Principal Component Analysis. The main results of this study will be presented with a particular focus on the role of the optical system and the attainable spatial and energy resolution.

physics.ins-det

Euclid's Near-Infrared Spectrometer and Photometer ready for flight -- review of final performance

ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the survey strategy, we focus our attention on the NISP Data Processing Unit's Application Software, highlighting the experimental process to obtain the final parametrization of the on-board processing of data produced by the array of 16 Teledyne HAWAII-2RG (HgCdTe) detectors. We report results from the latest ground test campaigns with the flight configuration hardware - complete optical system (Korsh anastigmat telescope), detectors array (0.56 deg$^2$ field of view), and readout systems (16 Digital Control Units and Sidecar ASICs). The performance of the on-board processing is then presented. We also describe a major issue found during the final test phase. We show how the problem was identified and solved thanks to an intensive coordinated effort of an independent review `Tiger' team, lead by ESA, and a team of NISP experts from the Euclid Consortium. An extended PLM level campaign at ambient temperature in Liège and a dedicated test campaign conducted in Marseille on the NISP EQM model eventually confirmed the resolution of the problem. Finally, we report examples of the outstanding spectrometric (using a Blue and two Red Grisms) and photometric performance of the NISP instrument, as derived from the end-to-end payload module test campaign at FOCAL 5 -- CSL; these results include the photometric Point Spread Function (PSF) determination and the spectroscopic dispersion verification.

astro-ph.IM

Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary

The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data. This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.

astro-ph.IM

Intrinsic limits on resolutions in muon- and electron-neutrino charged-current events in the KM3NeT/ORCA detector

Studying atmospheric neutrino oscillations in the few-GeV range with a multimegaton detector promises to determine the neutrino mass hierarchy. This is the main science goal pursued by the future KM3NeT/ORCA water Cherenkov detector in the Mediterranean Sea. In this paper, the processes that limit the obtainable resolution in both energy and direction in charged-current neutrino events in the ORCA detector are investigated. These processes include the composition of the hadronic fragmentation products, the subsequent particle propagation and the photon-sampling fraction of the detector. GEANT simulations of neutrino interactions in seawater produced by GENIE are used to study the effects in the 1 - 20 GeV range. It is found that fluctuations in the hadronic cascade in conjunction with the variation of the inelasticity y are most detrimental to the resolutions. The effect of limited photon sampling in the detector is of significantly less importance. These results will therefore also be applicable to similar detectors/media, such as those in ice.

physics.ins-det

The EU DataGrid Workload Management System: towards the second major release

In the first phase of the European DataGrid project, the 'workload management' package (WP1) implemented a working prototype, providing users with an environment allowing to define and submit jobs to the Grid, and able to find and use the ``best'' resources for these jobs. Application users have now been experiencing for about a year now with this first release of the workload management system. The experiences acquired, the feedback received by the user and the need to plug new components implementing new functionalities, triggered an update of the existing architecture. A description of this revised and complemented workload management system is given.

cs.DC

The first deployment of workload management services on the EU DataGrid Testbed: feedback on design and implementation

Application users have now been experiencing for about a year with the standardized resource brokering services provided by the 'workload management' package of the EU DataGrid project (WP1). Understanding, shaping and pushing the limits of the system has provided valuable feedback on both its design and implementation. A digest of the lessons, and "better practices", that were learned, and that were applied towards the second major release of the software, is given.

cs.DC