Searcharxiv⌕ Search

arXiv subjects

F. Jeanneau

Publications and source records attributed to F. Jeanneau.

24 records · Page 2Linked to original sources

An ageing study of resistive micromegas for the HL-LHC environment

Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiation (X-rays, cold neutrons, $^{60}$Co gammas and alphas) above the equivalent charge produced at the detector in five HL-LHC running years without showing any degradation of the performances in terms of gain and energy resolution. This study has been completed with the characterization of the tracking performances in terms of efficiency and spatial resolution, verifying the compatibility of results obtained with both resistive micromegas detectors, irradiated and non-irradiated one.

physics.ins-det↗

The silicon micro-strip detector plane for the LOFT/Wide Field Monitor

The main objective of the Wide Field Monitor (WFM) on the LOFT mission is to provide unambiguous detection of the high-energy sources in a large field of view, in order to support science operations of the LOFT primary instrument, the LAD. The monitor will also provide by itself a large number of results on the timing and spectral behaviour of hundreds of galactic compact objects, Active Galactic Nuclei and Gamma-Ray Bursts. The WFM is based on the coded aperture concept where a position sensitive detector records the shadow of a mask projected by the celestial sources. The proposed WFM detector plane, based on Double Sided micro-Strip Silicon Detectors (DSSD), will allow proper 2-dimensional recording of the projected shadows. Indeed the positioning of the photon interaction in the detector with equivalent fine resolution in both directions insures the best imaging capability compatible with the allocated budgets for this telescope on LOFT. We will describe here the overall configuration of this 2D-WFM and the design and characteristics of the DSSD detector plane including its imaging and spectral performances. We will also present a number of simulated results discussing the advantages that this configuration offers to LOFT. A DSSD-based WFM will in particular reduce significantly the source confusion experienced by the WFM in crowded regions of the sky like the Galactic Center and will in general increase the observatory science capability of the mission.

astro-ph.IM↗

Performances of Anode-resistive Micromegas for HL-LHC

Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of ~98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of \sim98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.

physics.ins-det↗

Performances and ageing study of resistive-anodes Micromegas detectors for HL-LHC environment

With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions like, for instance, the muons chambers of the ATLAS detector. Detectors based on the Micromegas principle should be good alternatives for the detector upgrade in the HL-LHC framework because of a good spatial (<100 \mum) and time (few ns) resolutions, high-rate capability, radiation hardness, good robustness and the possibility to build large areas. The aim of this study is to demonstrate that it is possible to reduce the discharge probability and protect the electronics by using a resistive anode plane in a high flux hadrons environment. Several prototypes of 10x10 cm2, with different pitches (0.5 to 2 mm) and different resistive layers have been tested at CERN (pi+@SPS). Several tests have been performed with a telescope at different voltages to assess the performances of the detectors in terms of position resolution and efficiency. The spark behaviour in these conditions has also been evaluated. Resistive coating has been shown to be a successful method to reduce the effect of sparks on the efficiency of micromegas. A good spatial resolution (~80 \mum) can be reached with a resistive strip coating detector of 1mm pitch and a high efficiency (> 98%) can be achieved with resistive-anode micromegas detector. An X-rays irradiation has been also performed, showing no ageing effect after more than 21 days exposure and an integrated charge of almost 1C.

physics.ins-det↗

Aging studies of Micromegas prototypes for the HL-LHC

The micromegas technology is a promising candidate to replace the forward muon chambers for the luminosity upgrade of ATLAS. The LHC accelerator luminosity will be five times the nominal one, increasing background and pile-up event probability. This requires detector performances which are currently under study in intensive R&D activities. Aging is one of the key issues for a high-luminosity LHC application. For this reason, we study the properties of resistive micromegas detectors under intense X-ray radiation and under thermal neutrons in different CEA-Saclay facilities. This study is complementary to those already performed using fast neutrons.

physics.ins-det↗

Neutron imaging with a Micromegas detector

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomographic image achieved with this kind of detector is very encouraging. The next worthwhile development for neutron imaging is to achieve a bi-dimensional detector, which is presented in the second part of this study. The purpose of measurements was to investigate various operational parameters to optimize the spatial resolution. Through these measurements the optimum spatial resolution has been found to be around 160 microns (standard deviation) using Micromegas operating in double amplification mode. Several 2D imaging tests have been carried out. Some of these results have revealed fabrication defects that occurred during the manufacture of Micromegas and that are limiting the full potential of the present neutron imaging system.

physics.ins-det↗