SearcharxivSearch

arXiv subjects

F. Leonard

Publications and source records attributed to F. Leonard.

15 recordsLinked to original sources

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

physics.ins-det

New Technologies for Discovery

For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.

physics.ins-det

An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.

physics.ins-det

Bound states of the $ϕ^4$ model via the nonperturbative renormalization group

Using the nonperturbative renormalization group, we study the existence of bound states in the symmetry-broken phase of the scalar $ϕ^4$ theory in all dimensions between two and four and as a function of the temperature. The accurate description of the momentum dependence of the two-point function, required to get the spectrum of the theory, is provided by means of the Blaizot--Méndez-Galain--Wschebor approximation scheme. We confirm the existence of a bound state in dimension three, with a mass within 1% of previous Monte-Carlo and numerical diagonalization values.

cond-mat.stat-mech

Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.

hep-ex

Search for Majorana neutrinos with the first two years of EXO-200 data

Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0νββ$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have established the lifetime of this decay to be longer than $10^{25}$ yr, corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure, representing an almost fourfold increase from our earlier published datasets. We have improved the detector resolution at the $^{136}$Xe double-beta-decay Q-value to $σ$/E = 1.53% and revised the data analysis. The obtained half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of 2.7 compared to previous EXO-200 results. We find no statistically significant evidence for $0νββ$ decay and set a half-life limit of $1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further running of the EXO-200 detector and future $0νββ$ decay searches with nEXO.

nucl-ex

An improved measurement of the 2νββ half-life of Xe-136 with EXO-200

We report on an improved measurement of the 2νββ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2νββ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2νββ decay to date.

nucl-ex

Search for Neutrinoless Double-Beta Decay in $^{136}$Xe with EXO-200

We report on a search for neutrinoless double-beta decay of $^{136}$Xe with EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1σ$ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay $T_{1/2}^{0νββ}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

hep-ex

The EXO-200 detector, part I: Detector design and construction

EXO-200 is an experiment designed to search for double beta decay of $^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.

physics.ins-det

Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

nucl-ex

Nanoscale periodicity in stripe-forming systems at high temperature: Au/W(110)

We observe using low-energy electron microscopy the self-assembly of monolayer-thick stripes of Au on W(110) near the transition temperature between stripes and the non-patterned (homogeneous) phase. We demonstrate that the amplitude of this Au stripe phase decreases with increasing temperature and vanishes at the order-disorder transition (ODT). The wavelength varies much more slowly with temperature and coverage than theories of stress-domain patterns with sharp phase boundaries would predict, and maintains a finite value of about 100 nm at the ODT. We argue that such nanometer-scale stripes should often appear near the ODT.

cond-mat.mtrl-sci

Optically Modulated Conduction in Chromophore-Functionalized Single-Wall Carbon Nanotubes

We demonstrate an optically active nanotube-hybrid material by functionalizing single-wall nanotubes with an azo-based chromophore. Upon UV illumination, the conjugated chromophore undergoes a cis-trans isomerization leading to a charge redistribution near the nanotube. This charge redistribution changes the local electrostatic environment, shifting the threshold voltage and increasing the conductivity of the nanotube transistor. For a ~1-2% coverage, we measure a shift in the threshold voltage of up to 1.2 V. Further, the conductance change is reversible and repeatable over long periods of time, indicating that the chromophore functionalized nanotubes are useful for integrated nano-photodetectors.

cond-mat.mtrl-sci

Size-dependent effects on electrical contacts to nanotubes and nanowires

Metal-semiconductor contacts play a key role in electronics. Here we show that for quasi-one dimensional (Q1D) structures such as nanotubes and nanowires, side contact with the metal only leads to weak band realignment, in contrast with bulk metal-semiconductor contacts. Schottky barriers are much reduced compared with the bulk limit, and should facilitate the formation of good contacts. However, the conventional strategy of heavily doping the semiconductor to obtain Ohmic contacts breaks down as the nanowire diameter is reduced. The issue of Fermi level pinning is also discussed, and it is demonstrated that the unique density of states of Q1D structures makes them less sensitive to this effect. Our results agree with recent experimental work, and should apply to a broad range of Q1D materials.

cond-mat.mtrl-sci

Multiple Functionality in Nanotube Transistors

Calculations of quantum transport in a carbon nanotube transistor show that such a device offers unique functionality. It can operate as a ballistic field-effect transistor, with excellent characteristics even when scaled to 10 nm dimensions. At larger gate voltages, channel inversion leads to resonant tunneling through an electrostatically defined nanoscale quantum dot. Thus the transistor becomes a gated resonant tunelling device, with negative differential resistance at a tunable threshold. For the dimensions considered here, the device operates in the Coulomb blockade regime, even at room temperature.

cond-mat

Negative differential resistance in nanotube devices

Carbon nanotube junctions are predicted to exhibit negative differential resistance, with very high peak-to-valley current ratios even at room temperature. We treat both nanotube p-n junctions and undoped metal-nanotube-metal junctions, calculating quantum transport through the self-consistent potential within a tight-binding approximation. The undoped junctions in particular may be suitable for device integration.

cond-mat