Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment

This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy resolution of $σ$ = 4.0$\pm$0.2% at 1 MeV, and efficient pulse-shape discrimination of low $dE/dx$ (electronic recoil) and high $dE/dx$ (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85$\pm$3 cm is measured in each segment. The 0.1% by mass concentration of $^{6}$Li in the scintillator results in a measured neutron capture time of $τ$ = 42.8$\pm$0.2 $μs$. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

physics.ins-det↗

Update on the MiniCLEAN Dark Matter Experiment

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.

physics.ins-det↗

delta S = 2 nonleptonic hyperon decays

A sensitive search for the rare decays Ω^- \to Λπ^- and Ξ^0 \to p π^- has been performed using data from the 1997 run of the HyperCP (Fermilab E871) experiment. Limits on other such processes do not exclude the possibility of observable rates for |ΔS| = 2 nonleptonic hyperon decays, provided the decays occur through parity-odd operators. We obtain the branching-fraction limits B(Ω^- \to Λπ^-)< 2.9 x 10^{-6} and B(Ξ^0 \to p π^-)< 8.2 x 10^{-6}, both at 90% confidence level.

hep-ex↗

Measurement of the Alpha Asymmetry Parameter for the Omega- to Lambda K- Decay

We have measured the alpha parameter of the Omega- to Lambda K- decay using data collected with the HyperCP spectrometer during the 1997 fixed-target run at Fermilab. Analyzing a sample of 0.96 million Omega- to Lambda K^-, Lambda to p pi- decays, we obtain alpha_Omega*alpha_Lambda = [1.33+/-0.33(stat)+/-0.52(syst)] x 10^{-2}. With the accepted value of alpha_Lambda, alpha_Omega is found to be [2.07+/-0.51(stat)+/-0.81(syst)] x 10^{-2}.

hep-ex↗

Evidence for the Decay Sigma+ -> p mu+ mu-

We report the first evidence for the decay Sigma+ -> p mu+ mu- from data taken by the HyperCP experiment(E871) at Fermilab. Based on three observed events, the branching ratio is B(Sigma+ -> p,mu+,mu-) = [8.6 +6.6,-5.4(stat) +/-5.5(syst)] x 10**-8. The narrow range of dimuon masses may indicate that the decay proceeds via a neutral intermediate state, Sigma+ -> p P0, P0 -> mu+ mu-, with a P0 mass of 214.3 +/- 0.5 MeV/c**2 and branching ratio B(Sigma+ -> p P0; P0 -> mu+ mu-) = [3.1 +2.4,-1.(stat) +/-1.5(syst)] x 10**-8.

hep-ex↗

Search for CP Violation in Charged-Xi and Lambda Hyperon Decays

We have compared the proton and antiproton angular distributions in 117 million Xi-minus -> Lambda + pi-minus -> proton + pi-minus + pi-minus and 41 million anti-Xi-minus -> anti-Lamba + pi-plus -> antiproton + pi-plus + pi-plus decays using a subset of the data from the HyperCP experiment (E871) at Fermilab. We find no evidence of CP violation, with the direct-CP-violating parameter $A_{ΞΛ} = \frac{α_Ξα_Λ - \barα_Ξ\barα_Λ}{α_Ξα_Λ + \barα_Ξ\barα_Λ} = [0.0+/-5.1(stat)+/-4.4(syst)]{\times}10^{-4}$.

hep-ex↗

High Statistics Search for the Theta+(1.54) Pentaquark State

We have searched for Theta+(1.54) -> K0,p decays using data from the 1999 run of the HyperCP experiment at Fermilab. We see no evidence for a narrow peak in the K0,p mass distribution near 1.54 GeV/c among 106,000 K0,p candidates, and obtain an upper limit for the fraction of Theta+(1.54) to K0,p candidates of <0.3% at 90% confidence.

hep-ex↗

HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays

The HyperCP experiment (Fermilab E871) was designed to search for rare phenomena in the decays of charged strange particles, in particular CP violation in $Ξ$ and $Λ$ hyperon decays with a sensitivity of $10^{-4}$. Intense charged secondary beams were produced by 800 GeV/c protons and momentum-selected by a magnetic channel. Decay products were detected in a large-acceptance, high-rate magnetic spectrometer using multiwire proportional chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection system. Nearly identical acceptances and efficiencies for hyperons and antihyperons decaying within an evacuated volume were achieved by reversing the polarities of the channel and spectrometer magnets. A high-rate data-acquisition system enabled 231 billion events to be recorded in twelve months of data-taking.

hep-ex↗