SearcharxivSearch

arXiv subjects

F. M. Brunbauer

Publications and source records attributed to F. M. Brunbauer.

At least 19 recordsLinked to original sources

Dark Matter Sensitivity of the CYGNO Detector with HFO-1234ze Enhanced Gas Mixtures

The CYGNO collaboration introduces an innovative approach to direct dark matter detection, proposing a high-resolution optical Time Projection Chamber. It operates at atmospheric pressure with a He:CF$_{4}$ (60:40) gas mixture and uses a triple Gas Electron Multiplier stage for signal amplification. A key feature is its optical readout system, which captures the scintillation light produced during the electron avalanche. This setup allows 3D event reconstruction by combining the time profile of the light detected by photomultiplier tubes with high-granularity, pixelated X-Y tracking recorded by a scientific camera. The CYGNO experiment's projected sensitivity to both spin-independent and spin-dependent interactions is competitive in the framework of directional dark matter detectors. However, incorporating a hydrogen-based gas would introduce an even lighter target, further improving the detection potential at low dark matter masses. In this work, we present the performance characterization of one of the CYGNO experiment prototypes, MANGO, operated with the standard gas mixture enriched with varying concentrations of HFO-1234ze, a gas with a promising low global warming potential. The study includes measurements of the detector charge gain and scintillation yield for each configuration. In addition, to evaluate the impact of HFO-1234ze on scintillation light quenching, the secondary scintillation spectrum was collected for each gas mixture tested.

physics.ins-det

Optical effects in Gaseous Electron Multipliers (GEMs)

Optical time projection chambers (OTPCs) are well suited for applications that require the highest spatial resolution for particle track reconstruction. The MIGDAL experiment uses a glass GEM-based OTPC and observes a systematic excess in both the intensity and width of particle tracks in its optical readout, when compared with charge readout simulations. One hypothesis is that scintillation light produced inside a GEM hole during the avalanche propagates through the GEM substrate and exits neighboring holes. We present lab measurements testing this hypothesized optical broadening effect in three types of GEM substrates: glass, ceramic, and FR4. Our observations quantify this optical broadening and demonstrate it to be strongest in glass GEMs. Additionally, we use Geant4 simulations to both reproduce our observations and quantify optical broadening effects in realistic charge avalanches. Applying our glass GEM effects to simulated particle tracks yields increases of track intensity and widths by up to around 26% and 31%, respectively. This may explain the larger than expected intensity and track widths observed in the MIGDAL OTPC and is expected to be an observed effect in all GEM-based OTPCs.

physics.ins-det

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Optical readout of MPGDs with solid wavelength shifters

Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle detection. CF4 is widely used as a scintillating gas because its emission lies in the visible range, where optical sensors are most sensitive. However, to reduce reliance on greenhouse gas, such as CF4, which also has limited availability, alternative gas mixtures emitting scintillation light in the ultraviolet range can be used in combination with wavelength shifters. We investigate the spatial resolution achievable with optically read out Gaseous Electron Multipliers (GEMs) and Micromegas when using solid wavelength shifter layers such as Tetraphenyl butadiene (TPB). TPB coatings on the anode of glass Micromegas achieve the best spatial resolution of 0.22 mm owing to the minimal distance between the origin of the scintillation light and the wavelength shifter. Nevertheless, TPB layers were also shown to achieve moderate spatial resolution in combination with optically read out GEMs.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Nanodiamond photocathodes for MPGD-based single photon detectors

This study investigates the suitability of Hydrogenated NanoDiamond (HND) materials as an alternative for CsI in MPGD-based photon detectors. The research focuses on characterizing HND photocathodes coupled with THGEM + Micromegas-based detectors. The HND grains were prepared via hydrogenation and stored in water for more than two years. They were then coated on PCB discs or THGEMs using a pulsed spray technique. The resulting quantum efficiency (QE) values (~4% at 122 nm) were found to be within a factor of 10 of the best freshly hydrogenated samples reported in the literature ( ~40% at 120 nm). The robustness of reflective HND photocathodes against ion bombardment was measured to be about 10 times larger than the corresponding CsI one after the same charge accumulation. Furthermore, THGEM characterization indicates minimal alteration in response after HND coatings. These results suggest that HND holds potential as a more robust photocathode for gaseous detectors, offering improved performance in single-photon detection applications.

physics.ins-det

Overlap-aware segmentation for topological reconstruction of obscured objects

The separation of overlapping objects presents a significant challenge in scientific imaging. While deep learning segmentation-regression algorithms can predict pixel-wise intensities, they typically treat all regions equally rather than prioritizing overlap regions where attribution is most ambiguous. Recent advances in instance segmentation show that weighting regions of pixel overlap in training can improve segmentation boundary predictions in regions of overlap, but this idea has not yet been extended to segmentation regression. We address this with Overlap-Aware Segmentation of ImageS (OASIS): a new segmentation-regression framework with a weighted loss function designed to prioritize regions of object-overlap during training, enabling extraction of pixel intensities and topological features from heavily obscured objects. We demonstrate OASIS in the context of the MIGDAL experiment, which aims to directly image the Migdal effect--a rare process where electron emission is induced by nuclear scattering--in a low-pressure optical time projection chamber. This setting poses an extreme test case, as the target for reconstruction is a faint electron recoil track which is often heavily-buried within the order(s)-of-magnitude brighter nuclear recoil track. Compared to unweighted segmentation regression, we demonstrate OASIS's novel overlap region-targeted loss function weight to be the single most important training weight for improving intensity and topological reconstructions of the low-energy electron tracks that tend to be most dominated by pixel overlap. Averaging over eight training campaigns, we further show the addition of overlap-targeted weights to improve median intensity reconstruction errors from -41.1% to -13.3% for these low-energy electrons. These performance gains demonstrate OASIS as a generalizable methodology for recovering obscured signals in overlap-dominated regions.

hep-ex

Measurements of enriched 155 Gd and 157Gd converters with the NMX detector on the nTOF EAR2 beam line at CERN

The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of flight experiment (nTOF) at CERN to study the feasibility of an upgrade to enriched Gd. A 10 x 10 cm^2 prototype of the NMX detector was equipped with two enriched Gd samples (157Gd and 155Gd) that were attached with copper tape to the natural Gd cathode of the detector. Three sets of measurements were taken, with the beam focused on either the natural Gd, the 157Gd, or the 155Gd samples. Using the time-of-flight technique with the subsequent conversion of time-of-flight into energy, the resonant region between 1 eV and 200 eV of the 157Gd and 155Gd cross sections was studied. The peaks in the resonant region were clearly visible, having higher ADC values in the ADC spectrum. Additionally, the resonant peaks had a larger number of counts per energy bin. In the thermal neutron energy range, the count rate at the center of the beam was measured for natural Gd, 157Gd, and 155Gd. Enriched 157Gd showed an efficiency that was between 60 - 180% higher, compared to natural Gd, for neutron wavelengths between 0.8 A and 1.8 A. The measured 60 % increase in efficiency at 1.8 A is lower than expected from simulations (100 %) and previous measurements with solid state detectors (80 %). Gamma background detection, bad focusing, and saturation effects most likely explain this deviation. An upgrade of the natural Gd converter to enriched 157Gd would thus lead to an efficiency increase of at least 60 %. The measurements presented in this paper are the first successful time-of-flight measurements with the NMX detector prototype and the ESS VMM readout.

physics.ins-det

Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection

Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlapping tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.

hep-ex

The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout

The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.

physics.ins-det

Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors

Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometry are pursued to maximise spatial resolution. To compare MicroPattern Gaseous Detector (MPGD) technologies, focused low-energy X-ray beams at the SOLEIL synchrotron facility were used to record and extract point spread function widths with Micromegas and GEM detectors. Point spread function width of $\approx$108\,\microns for Micromegas and $\approx$127\,\microns for GEM foils were extracted. The scanning of the beam with different intensities, energies and across the detector active region can be used to quantify resolution-limiting factors and improve imaging detectors using MPGD amplification stages.

physics.ins-det

Study of nanodiamond photocathodes for MPGD-based detectors of single photons

The proposed new Electron-Ion Collider poses a technical and intellectual challenge for the detector design to accommodate the long-term diverse physics goals envisaged by the program. This requires a 4π detector system capable of reconstructing the energy and momentum of final state particles with high precision. The Electron-Ion Collider also requires identification of particles of different masses over a wide momentum range. A diverse spectrum of Particle Identification detectors has been proposed. Of the four types of detectors for hadron identification, three are based on Ring Imaging Cherenkov Counter technologies, and one is realized by the Time of Flight method. The quest for a novel photocathode, sensitive in the far vacuum ultra violet wavelength range and more robust than cesium iodide, motivated an R&D programme to explore nano-diamond (ND) based photocathodes, started by a collaboration between INFN and CNR Bari and INFN Trieste. Systematic measurements of the photo emission in different Ar-CH4 and Ar-CO2 gas mixtures with various types of ND powders and Hydrogenated ND (H-ND) powders are reported. A first study of the response of THGEMs coated with different photocathode materials is presented. The progress of this R&D programme and the results obtained so far by these exploratory studies are described.

physics.ins-det

Progress in coupling MPGD-based Photon Detectors with Nanodiamond Photocathodes

The next generation of gaseous photon detectors is requested to overcome the limitations of the available technology, in terms of resolution and robustness. The quest for a novel photocathode, sensitive in the far vacuum ultra violet wavelength range and more robust than present ones, motivated an R&D programme to explore nanodiamond based photoconverters, which represent the most promising alternative to cesium iodine. A procedure for producing the novel photocathodes has been defined and applied on THGEMs samples. Systematic measurements of the photo emission in different Ar/CH4 and Ar/CO2 gas mixtures with various types of nanodiamond powders have been performed. A comparative study of the response of THGEMs before and after coating demonstrated their full compatibility with the novel photocathodes.

physics.ins-det

Observation of strong wavelength-shifting in the argon-tetrafluoromethane system

We report the scintillation spectra of Ar-CF$_4$ mixtures in the range 210-800~nm, obtained under X-ray irradiation for various pressures (1-5~bar) and concentrations (0-100%). Special care was taken to eliminate effects related to space charge and recombination, so that results can be extrapolated following conventional wisdom to those expected for minimum ionizing particles under the typical electric fields employed in gaseous instrumentation. Our study sheds light into the microscopic pathways leading to scintillation in this family of mixtures.

physics.ins-det

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.

hep-ex

X-ray imaging with Micromegas detectors with optical readout

In the last years, optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass anode coupled to a CMOS camera. Effective X-ray radiography was demonstrated using integrated imaging approach. High granularity values have been reached for low-energy X-rays from radioactive sources and X-ray generators. Detector characterization with X-ray radiography has led to two applications: neutron imaging for non-destructive examination of highly gamma-ray emitting objects and beta imaging for the single cell activity tagging in the field of oncology drug studies. First measurements investigating the achievable spatial resolution of the glass Micromegas detector at the SOLEIL synchrotron facility with a high-intensity and flat irradiation field will be shown in this article.

physics.ins-det

Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

physics.ins-det

Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC

We are developing gaseous photon detectors for Cherenkov imaging applications in the experiments at the future Electron Ion Collider. CsI, converting photons in the far ultraviolet range, is, so far, the only photoconverter compatible with the operation of gaseous detectors. It is very delicate to handle due to its hygroscopic nature: the absorbed water vapour decomposes the CsI molecule. In addition, its quantum efficiency degrades under ion bombardment. These are the key reasons to quest for novel, less delicate materials for photocathodes adequate for gaseous photon detectors. Layers of hydrogenated nanodiamond particles have recently been proposed as an alternative material and have shown promising characteristics. The performance of nanodiamond photocathodes coupled to thick GEM-based detectors is the object of our ongoing R\&D. The first phase of these studies includes the characterization of thick GEM coated with nanodiamond layers and the robustness of its photoconverting properties with respect to the bombardment by ions from the multiplication process in the gaseous detector. The approach is described in detail as well as all the results obtained so far within these exploratory studies.

physics.ins-det