Searcharxiv⌕ Search

arXiv subjects

F. M. Piegsa

Publications and source records attributed to F. M. Piegsa.

At least 37 records · Page 2Linked to original sources

Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations

The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have been further analyzed by Berezhiani et al.(2009-2017), and signals, compatible with $n-n'$ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test these signals. In this paper, we describe and motivate our choice of run configurations with an optimal filling time of $29~$s, storage times of $180~$s and $380~$s, and applied magnetic fields of $10~μ$T and $20~μ$T. The choice of these run configurations ensures a reliable overlap in settings with the previous efforts and also improves the sensitivity to test the signals. We also elaborate on the technique of normalizing the neutron counts, making such a counting experiment at the ultra-cold neutron source at the Paul Scherrer Institute possible. Furthermore, the magnetic field characterization to meet the requirements of this $n-n'$ oscillation search is demonstrated. Finally, we show that this effort has a statistical sensitivity comparable to the current leading constraints for $n-n'$ oscillations.

nucl-ex↗

Magnetic field uniformity in neutron electric dipole moment experiments

Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of neutrons and mercury atoms. The theoretical predictions for these effects were verified by dedicated measurements with the single-chamber nEDM apparatus installed at the Paul Scherrer Institute.

physics.ins-det↗

The Pulsed Neutron Beam EDM Experiment

We report on the Beam EDM experiment, which aims to employ a pulsed cold neutron beam to search for an electric dipole moment instead of the established use of storable ultracold neutrons. We present a brief overview of the basic measurement concept and the current status of our proof-of-principle Ramsey apparatus.

physics.ins-det↗

The n2EDM experiment at the Paul Scherrer Institute

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.

physics.ins-det↗

muCool: A novel low-energy muon beam for future precision experiments

Experiments with muons ($μ^{+}$) and muonium atoms ($μ^{+}e^{-}$) offer several promising possibilities for testing fundamental symmetries. Examples of such experiments include search for muon electric dipole moment, measurement of muon $g-2$ and experiments with muonium from laser spectroscopy to gravity experiments. These experiments require high quality muon beams with small transverse size and high intensity at low energy. At the Paul Scherrer Institute, Switzerland, we are developing a novel device that reduces the phase space of a standard $μ^{+}$ beam by a factor of $10^{10}$ with $10^{-3}$ efficiency. The phase space compression is achieved by stopping a standard $μ^{+}$ beam in a cryogenic helium gas. The stopped $μ^{+}$ are manipulated into a small spot with complex electric and magnetic fields in combination with gas density gradients. From here, the muons are extracted into the vacuum and into a field-free region. Various aspects of this compression scheme have been demonstrated. In this article the current status will be reported.

physics.acc-ph↗

muCool: A next step towards efficient muon beam compression

A novel device to compress the phase space of a muon beam by a factor of $10^{10}$ with a $10^{-3}$ efficiency is under development. A surface muon beam is stopped in a helium gas target consisting of several compression stages, wherein strong electric and magnetic fields are applied. The spatial extent of the stopped muon swarm is decreased by means of these fields until muons with eV energy are extracted into vacuum through a small orifice. It was measured that a 20 cm long muon stop distribution can be compressed in longitudinal direction to sub-mm extent within 2 ${\rm μs}$. Additionally, a drift perpendicular to the magnetic field of the compressed low-energy muon swarm was successfully demonstrated, paving the way towards the extraction from the gas and re-acceleration of the muons.

physics.acc-ph↗

nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.

physics.ins-det↗

Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches

We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.

physics.ins-det↗

A simple method of coil design

In this article we present a method to design a coil producing an arbitrarily shaped magnetic field by restricting the path of the coil's wires to a regular grid. The solution is then found by a simple least squares minimum. We discuss practical applications, in particular in the active magnetic field stabilization system of the neutron electric dipole moment experiment at the Paul Scherrer Institute in Villigen, Switzerland. We also publish the software implementation of the method.

physics.ins-det↗

High-power closed-cycle $^4$He cryostat with top-loading sample exchange

We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure of approximately 250~mbar. Moreover, the cryostat allows for exchange of different cryostat-inserts as well as fast and easy "wet" top-loading of samples directly into the 1 K pot with a turn-over time of less than 75~min. Starting from room temperature and using a $^4$He cryostat-insert, a base temperature of 1.0~K is reached within approximately seven hours and a cooling power of 250~mW is established at 1.24~K.

physics.ins-det↗

Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields

We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range $10^{-24}~\textrm{eV} \le m_a \le 10^{-17}~\textrm{eV}$. Our null result sets the first laboratory constraints on the coupling of axion dark matter to gluons, which improve on astrophysical limits by up to 3 orders of magnitude, and also improves on previous laboratory constraints on the axion coupling to nucleons by up to a factor of 40.

hep-ph↗

Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute

This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.

physics.ins-det↗

Ultracold neutron production and up-scattering in superfluid helium between 1.1 K and 2.4 K

Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of $(6.9 \pm 1.7)\,\mathrm{cm^{-3}\,s^{-1}}$, which includes a correction for losses in the converter during UCN extraction caused by a short storage time, but not accounting for UCN transport and detection efficiencies. The up-scattering rate of UCNs due to excitations in the superfluid was studied by scanning the temperature between 1.2-2.4 K. Using the temperature-dependent UCN production rate calculated from inelastic neutron scattering data in the analysis, the only UCN up-scattering process found to be present was from two-phonon scattering. Our analysis rules out contributions from the other scattering processes to $\lesssim 10\%$ of their predicted levels.

physics.ins-det↗

A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL). This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.

hep-ex↗

A device for simultaneous spin analysis of ultracold neutrons

We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.

physics.ins-det↗

Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy

We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCN of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of $1.1~\text{pT/cm}$. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.

physics.ins-det↗

Gravitational Depolarization of Ultracold Neutrons: Comparison with Data

We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.

physics.ins-det↗

Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field

We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.

physics.atom-ph↗