SearcharxivSearch

arXiv subjects

F. Rivero

Publications and source records attributed to F. Rivero.

10 recordsLinked to original sources

Offline Commissioning of the St. Benedict Gas Catcher

Precision measurements of $\beta$ decay transitions offer a promising channel through which the Standard Model (SM) can be probed. There is currently an ongoing effort to increase the precision on measurements of $\mathcal{F}t$-values for superallowed $\beta$ decay transitions between mirror nuclides. These allow for a determination of $V_{ud}$ which is complementary to that obtained from pure Fermi $0^+ \rightarrow 0^+$ transitions. The Superallowed Transition BEta-NEutrino Decay Ion Coincidence Trap (St. Benedict), under construction at the Nuclear Science Laboratory (NSL) at the University of Notre Dame, seeks to measure the Fermi-to-Gamow-Teller mixing ratio for transitions between mirror nuclei in order to expand the list of nuclides from which $V_{ud}$ can be extracted. Production and selection of the species of interest will be done in-flight, using the \textit{TwinSol} magnetic separator system. The first element of St. Benedict will be a large volume gas catcher which will thermalize radioactive ion beams for low energy delivery to the rest of the system. Offline commissioning of this gas catcher has been completed using an internal potassium source, and the device demonstrated a transport efficiency upwards of 95\% for pressures of 66 mbar and lower.

physics.ins-det

Off-line Commissioning of the St. Benedict Radio Frequency Quadrupole Ion Guide

The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the Nuclear Science Laboratory (NSL) of the University of Notre Dame. It aims to measure the beta-neutrino angular correlation parameter for superallowed mixed mirror beta decay transitions. Measurements of this kind offer unique insight into the electroweak part of the Standard Model through tests of unitarity of the Cabibbo-Kobayashi-Maskawa (CKM) matrix. St. Benedict is comprised of several beam-manipulating components including a radio frequency quadrupole (RFQ) ion guide. This ion guide features an off-line source at $90^\circ$ to the beam path for testing and calibration of downstream components once St. Benedict is online. Off-line commissioning of the ion guide demonstrated a transport efficiency greater than 95% for ions coming from the upstream RF carpet chamber. When taking ions from the $90^\circ$ off-line source a lower efficiency of 60% was obtained.

physics.ins-det

Precise Mass Measurement of the $^{149}$La-$^{149}$Ce-$^{149}$Pr isobaric chain

Penning trap mass measurements of $^{149}$La, $^{149}$Ce, and $^{149}$Pr were performed with the Canadian Penning Trap (CPT) at the CARIBU facility of Argonne National Laboratory using the phase-imaging ion-cyclotron-resonance technique. The resulting mass excess of $^{149}$La differs by 221 keV from a recent JYFLTRAP measurement, resulting in a significant change in the profile of the two-neutron separation energy for that isotopic chain. The mass excesses of $^{149}$Ce and $^{149}$Pr are determined with an eight-fold improvement in precision compared to previous time-of-flight ion-cyclotron-resonance measurements; the $^{149}$Ce value is consistent with AME2020, while the $^{149}$Pr mass excess is lower by 17.5 keV. The mass excesses of $^{149}$La and $^{149}$Pr reported in this work have been confirmed recently by a measurement with a multi-reflection time-of-flight mass spectrometer coupled to a $\beta$-time of flight detector at RIKEN, providing further validation of the present results.

nucl-ex

Exploration for Astromers near $^{132}$Sn with the Canadian Penning Trap

Nuclear isomers can have significant impacts on astrophysical nucleosynthesis processes, with recent efforts demonstrating that the population of isomeric states with different half-lives may require separate treatment in reaction networks to accurately capture the differences in heating or in identifiable electromagnetic signals. Several potential so-called ``astromers'' in tin and antimony isotopes near doubly-magic $^{132}$Sn were identified and direct mass measurements of their ground and isomeric states were performed with the Canadian Penning Trap at Argonne National Laboratory's CARIBU facility, and their impact on astrophysical reaction rates and in reaction networks calculated. It was found that $^{129g,m}$Sn, with measured mass excesses of $-80 593.2(25)$ keV and $-80 557.4(25)$ keV, respectively, and an excitation energy of $35.8(35)$ keV, behaves as an astromer during neutron capture in the $i$-process and in the $r$-process.

nucl-ex

Off-line Commissioning of the St. Benedict Radiofrequency Quadrupole Cooler-Buncher

The St. Benedict ion trapping system, which aims to measure the $\beta-\nu$ angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the $V_{ud}$ element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width. The commissioning results also determined the trapping efficiency to be 93(1)$\%$ and the trapping half-life to be 20.0(5) s.

physics.ins-det

Astrophysical significance of the isomer $^{119m}$Ag demonstrated through direct mass measurement

The abundance of elements heavier than iron produced via the astrophysical rapid-neutron capture process depends sensitively on the atomic mass of the involved nuclei as well as the behavior of a few special types of nuclear isomers called astromers. High-precision mass measurements of $^{119}$Cd, $^{119}$Ag and their respective isomeric states have been performed with the Phase Imaging-Ion Cyclotron Resonance (PI-ICR) method with a precision of $\delta m/m \approx 10^{-8}$ using the Canadian Penning Trap (CPT). The ground state mass excess, as well as the excitation energy, agrees with recent Penning Trap measurements from JYFLTRAP. Network calculations using these new measurements revealed that, contrary to previous expectations, $^{119m}$Ag behaves as an astromer which significantly affects the population of $^{119}$Ag.

nucl-ex

Mass measurements of neutron-rich nuclides using the Canadian Penning Trap to inform predictions in the $r$-process rare-earth peak region

Studies aiming to determine the astrophysical origins of nuclei produced by the rapid neutron capture process ($r$ process) rely on nuclear properties as inputs for simulations. The solar abundances can be used as a benchmark for such calculations, with the $r$-process rare-earth peak (REP) around mass number ($A$) 164 being of special interest due to its presently unknown origin. With the advancement of rare isotope beam production over the last decade and improvement in experimental sensitivities, many of these REP nuclides have become accessible for measurement. Masses are one of the most critical inputs as they impact multiple nuclear properties, namely the neutron-separation energies, neutron capture rates, $\beta$-decay rates, and $\beta$-delayed neutron emission probabilities. In this work, we report masses of 20 neutron-rich nuclides (along the Ba, La, Ce, Pr, Nd, Pm, Gd, Dy and Ho isotopic chains) produced at the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory. The masses were measured with the Canadian Penning trap (CPT) mass spectrometer using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique. We then use these new masses along with previously published CPT masses to inform predictions for a Markov Chain Monte Carlo (MCMC) procedure aiming to identify the astrophysical conditions consistent with both solar data and mass measurements. We show that the MCMC responds to this updated mass information, producing refined results for both mass predictions and REP abundances.

nucl-ex

Precise Mass Measurement of the Longest Odd-Odd Chain of \boldmath $1^+$ Ground States

Precise mass measurements of the ground and isomeric states of the odd-odd $^{108, 110, 112, 114, 116}$Rh were performed using the Canadian Penning Trap at Argonne National Laboratory, showing good agreement with recent JYFLTRAP measurements. A new possible isomeric state of $^{114}$Rh was also observed. These isotopes are part of the longest odd-odd chain of identical ground-state spin-parity assignment of 1$^+$, spanning $^{104-118}$Rh, despite being in a region of deformation. Realistic phenomenological mean-field calculations using ``universal'' Wood-Saxon Hamiltonian were performed, which explained this phenomenon for the first time. In addition, multi-quasiparticle blocking calculations were performed to study the configuration of low-lying states in the odd-odd Rh nuclei, elucidating anomalous isomeric yield ratio observed for $^{114}$Rh.

nucl-ex

The Beta-decay Paul Trap Mk IV: Design and commissioning

The Beta-decay Paul Trap is an open-geometry, linear trap used to measure the decays of $^8$Li and $^8$B to search for a tensor contribution to the weak interaction. In the latest $^8$Li measurement of Burkey et al. (2022), $\beta$ scattering was the dominant experimental systematic uncertainty. The Beta-decay Paul Trap Mk IV reduces the prevalence of $\beta$ scattering by a factor of 4 through a redesigned electrode geometry and the use of glassy carbon and graphite as electrode materials. The trap has been constructed and successfully commissioned with $^8$Li in a new data campaign that collected 2.6 million triple coincidence events, an increase in statistics by 30% with 4 times less $\beta$ scattering compared to the previous $^8$Li data set.

physics.ins-det

Preliminary results of 3D-DDTC pixel detectors for the ATLAS upgrade

3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a 180GeV pion beam at CERN SPS. The substrate thickness of the sensors is about 200um, and different column depths are available, with overlaps between junction columns (etched from the front side) and ohmic columns (etched from the back side) in the range from 110um to 150um. The devices under test were bump bonded to the ATLAS Pixel readout chip (FEI3) at SELEX SI (Rome, Italy). We report leakage current and noise measurements, results of functional tests with Am241 gamma-ray sources, charge collection tests with Sr90 beta-source and an overview of preliminary results from the CERN beam test.

physics.ins-det