SearcharxivSearch

arXiv subjects

F. S. Porter

Publications and source records attributed to F. S. Porter.

At least 19 recordsLinked to original sources

Ubiquitous Interstellar Neutral Helium Detected with JWST

We report the discovery of ubiquitous neutral helium emission in sky spectra taken with JWST's NIRSpec instrument. The emission, with a wavelength of 1.0833 micron, resembles one of the "sky lines" that are seen by ground-based observatories. We examine this emission in all suitable NIRSpec spectra in the public archive, totaling 22 days of exposure time. We find that this He I emission is almost always present: it is well-detected in 80 percent of the observations, and in 53 percent of the individual exposures. The emission is highly time-variable: at a given pointing, the line intensity can vary by factors of several over the course of a day. The He I emission is strongest when JWST crosses through the cone of interstellar neutral helium that is gravitationally focused by the sun; intensity during the cone crossing is anti-correlated with solar activity. The low redshift and narrow velocity width of the He I line, and the elevated intensity when JWST crosses through the focusing cone, together indicate that origin of the He I emission is cold Milky Way gas passing through our solar system. JWST provides a new way to study this interstellar gas, revealing new insights such as extreme variability on timescales of hours to days, which has not been previously reported.

astro-ph.GA

A XRISM/Resolve view of the dynamics in the hot gaseous atmosphere of M87

The XRISM/Resolve microcalorimeter directly measured the gas velocities in the core of the Virgo Cluster, the closest example of AGN feedback in a cluster. This proximity allows us to resolve the kinematic impact of feedback on scales down to 5 kpc. Our spectral analysis reveals a high velocity dispersion of $\sigma_v$=262 (+45 / -38) km/s near the AGN, which steeply declines to ~60 km/s between 5 and 25 kpc in the northwest direction. The observed line-of-sight bulk velocity in all regions is broadly consistent with the central galaxy, M87, with a mild trend toward blueshifted motions at larger radii. Systematic uncertainties have been carefully assessed and do not affect the measurements. The central velocities, if attributed entirely to isotropic turbulence, correspond to a transonic ICM at sub-6 kpc scales with three-dimensional Mach number 0.69 (+0.14 / -0.11) and a non-thermal pressure fraction of 21 (+7 / -5)%. Simple models of weak shocks and sound waves and calculations assuming isotropic turbulence both support the hypothesis that the velocity field reflects a mix of shock-driven expansion and turbulence. Compared to other clusters observed by XRISM to date, M87's central region stands out as the most kinematically disturbed, exhibiting both the highest velocity dispersion and the largest 3D Mach number, concentrated at the smallest physical scales.

astro-ph.GA

The May 2024 Storm: dayside magnetopause and cusps in simulated soft X-Rays

The coronal mass ejection (CME) arriving at Earth on May 10, 2024 caused the most intense geomagnetic storm in the last two decades, and resulted in highly unusual magnetopause and cusp dynamics. We simulate soft X-Ray emission due to solar wind charge exchange with exospheric neutrals to image the global dayside dynamics, focusing on the impact of a dense CME current sheet during the storm main phase. The magnetopause moves inward to ~ 4 RE, and at the same time, the two cusps manifest as nearly parallel emission ridges in X-Ray. As the interplanetary magnetic field reverses, the cusp ridges move to higher latitudes for ~ 10 minutes after the reversal. The X-Ray emission can be detected by imagers to be flown on future missions to provide a global picture of the magnetopause and cusps with quantitative determination of their locations

physics.space-ph

The Structure of the Relativistic Fe Line in GX 340+0 as Viewed with XRISM/Resolve, NICER, and NuSTAR

We present a 152 ks XRISM/Resolve observation of the persistently accreting Z source GX 340+0. Simultaneous observations also occurred with NuSTAR and NICER for 22.47 ks and 2.7 ks, respectively. The source covered the normal branch to the flaring branching during the observations. The data from all three missions were modeled concurrently for each spectral branch. The superior energy resolution of XRISM/Resolve reveals structure within the iron emission line complex regardless of spectral state. We model the reprocessed Fe K line with a reflection model tailored for thermal illumination of the accretion disk by a neutron star. The currently available model encompasses the broad components, but narrow emission features remain at the ~5% level. These remaining features may be described by the presence of an ionized plasma in the system as has been observed in the Z source Cygnus X-2, but subsequent updates to the reflection model code may be able to explain these features.

astro-ph.HE

Frequently Used References For Atomic Data In X-ray Spectroscopy

Accurate atomic physics reference data are a crucial requirement for analysis and interpretation of observed spectra, even more so for observations with high spectral resolution. This document provides a curated list of atomic physics references frequently used for plasma diagnostics in X-ray spectroscopy, outside of comprehensive plasma models that typically come with their own underlying atomic databases. The list includes references to physical constants, laboratory benchmarks, transition energies, position and line shapes of neutral fluorescence lines, radiative branching ratios, and commonly used notation for prominent transitions. Quick-look tables for transition energies in H-, He-, and Li-like ions and line positions and shapes for fluorescence lines in neutrals. The main focus is on K-shell transitions. For the H- and He-like tables, we cite state-of-the art calculations that we consider currently the best available reference energies, which are considered high accuracy and thus typically used for energy scale calibration in laboratory measurements. Omissions in these tables are due to the lack of availability in the chosen references, and are not a statement about the relevance of these lines. Due to their complex and highly source-dependent line shape, the atomic data for neutrals is of lower accuracy than that for the highly charged ions, and the best reference data for these line shapes typically consist of empirical models derived from very high-resolution laboratory measurements. The table for neutrals provided here is consistent with the reference used for the energy gain scale calibration of XRISM/Resolve. This document is meant to serve as a resource to help find relevant references and conveniently formatted overview tables. When making use of the information found in these papers, credit should be given to their original authors by citing the appropriate references.

astro-ph.IM

Mechanical cryocooler noise observed in the ground testing of the Resolve X-ray microcalorimeter onboard XRISM

Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these detectors. We have observed this effect in the ground test data obtained with the Resolve instrument to be flown on the XRISM satellite. Resolve is a cryogenic X-ray microcalorimeter spectrometer with a required energy resolution of 7 eV at 6 keV. Five mechanical coolers are used to cool from ambient temperature to about 4 K: four two-stage Stirling coolers (STC) driven nominally at 15 Hz and a Joule-Thomson cooler (JTC) driven nominally at 52 Hz. In 2019, we operated the flight-model instrument for two weeks, in which we also obtained accelerometer data inside the cryostat at a low-temperature stage (He tank). X-ray detector and accelerometer data were obtained continuously while changing the JTC drive frequency, which produced a unique data set for investigating how the vibration from the cryocoolers propagates to the detector. In the detector noise spectra, we observed harmonics of both STCs and JTC. More interestingly, we also observed the low (<20 Hz) frequency beat between the 4'th JTC and 14'th STC harmonics and the 7'th JTC and the 23--24'th STC harmonics. We present here a description and interpretation of these measurements.

astro-ph.IM

A new benchmark of soft X-ray transition energies of Ne, CO$_2$, and SF$_6$: paving a pathway towards ppm accuracy

A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of Ne, CO$_2$, and SF$_6$ gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s-np fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the CO$_2$ result agrees well with previous measurements, the SF$_6$ spectrum appears shifted by ~0.5 eV, about twice the uncertainty of the earlier results. Our result for Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1-10 meV, however, systematic contributions still limit the uncertainty to ~40-100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1-10 meV.

astro-ph.IM

Micro-X Sounding Rocket Payload Re-flight Progress

Micro-X is an X-ray sounding rocket payload that had its first flight on July 22, 2018. The goals of the first flight were to operate a transition edge sensor (TES) X-ray microcalorimeter array in space and take a high-resolution spectrum of the Cassiopeia A supernova remnant. The first flight was considered a partial success. The array and its time-division multiplexing readout system were successfully operated in space, but due to a failure in the attitude control system, no time on-target was acquired. A re-flight has been scheduled for summer 2022. Since the first flight, modifications have been made to the detector systems to improve noise and reduce the susceptibility to magnetic fields. The three-stage SQUID circuit, NIST MUX06a, has been replaced by a two-stage SQUID circuit, NIST MUX18b. The initial laboratory results for the new detector system will be presented in this paper.

astro-ph.IM

Modeling a Three-Stage SQUID System in Space with the First Micro-X Sounding Rocket Flight

The Micro-X sounding rocket is a NASA funded X-ray telescope payload that completed its first flight on July 22, 2018. This event marked the first operation of Transition Edge Sensors (TESs) and their SQUID-based multiplexing readout system in space. Unfortunately, due to an ACS pointing failure, the rocket was spinning during its five minute observation period and no scientific data was collected. However, data collected from the internal calibration source marked a partial success for the payload and offers a unique opportunity to study the response of TESs and SQUIDs in space. Of particular interest is the magnetic field response of the NIST MUX06a SQUID readout system to tumbling through Earth's magnetic field. We present a model to explain the baseline response of the SQUIDs, which lead to a subset of pixels failing to "lock" for the full observational period. Future flights of the Micro-X rocket will include the NIST MUX18b SQUID system with dramatically reduced magnetic susceptibility.

astro-ph.IM

First operation of Transition-Edge Sensors in space with the Micro-X sounding rocket

With its first flight in 2018, Micro-X became the first program to fly Transition-Edge Sensors and their SQUID readouts in space. The science goal was a high-resolution, spatially resolved X-ray spectrum of the Cassiopeia A Supernova Remnant. While a rocket pointing error led to no time on target, the data was used to demonstrate the flight performance of the instrument. The detectors observed X-rays from the on-board calibration source, but a susceptibility to external magnetic fields limited their livetime. Accounting for this, no change was observed in detector response between ground operation and flight operation. This paper provides an overview of the first flight performance and focuses on the upgrades made in preparation for reflight. The largest changes have been upgrading the SQUIDs to mitigate magnetic susceptibility, synchronizing the clocks on the digital electronics to minimize beat frequencies, and replacing the mounts between the cryostat and the rocket skin to improve mechanical integrity. As the first flight performance was consistent with performance on the ground, reaching the instrument goals in the laboratory is considered a strong predictor of future flight performance.

astro-ph.IM

High-Precision Determination of Oxygen-K$α$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O$_2$ with 8 meV uncertainty. We reveal a systematic $\sim$450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O$_2$ literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

physics.atom-ph

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

astro-ph.IM

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

astro-ph.IM

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This flight marks the first successful operation of a Transition-Edge Sensor array and its time division multiplexing read-out system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The on-board calibration source provided X-rays in flight, and it is used to compare detector performance during pre-flight integration, flight, and after the successful post-flight recovery. This calibration data demonstrates the capabilities of the detector in a space environment as well as its potential for future flights.

astro-ph.IM

Exploring Solar-Terrestrial Interactions via Multiple Observers (A White Paper for the Voyage 2050 long-term plan in the ESA Science Programme)

This paper addresses the fundamental science question: "How does solar wind energy flow through the Earth's magnetosphere, how is it converted and distributed?". We need to understand how the Sun creates the heliosphere, and how the planets interact with the solar wind and its magnetic field, not just as a matter of scientific curiosity, but to address a clear and pressing practical problem: space weather, which can influence the performance and reliability of our technological systems, in space and on the ground, and can endanger human life and health. Much knowledge has already been acquired over the past decades, but the infant stage of space weather forecasting demonstrates that we still have a vast amount of learning to do. We can tackle this issue in two ways: 1) By using multiple spacecraft measuring conditions in situ in the magnetosphere in order to make sense of the fundamental small scale processes that enable transport and coupling, or 2) By taking a global approach to observations of the conditions that prevail throughout geospace in order to quantify the global effects of external drivers. A global approach is now being taken by a number of space missions under development and the first tantalising results of their exploration will be available in the next decade. Here we propose the next step-up in the quest for a complete understanding of how the Sun gives rise to and controls the Earth's plasma environment: a tomographic imaging approach comprising two spacecraft which enable global imaging of magnetopause and cusps, auroral regions, plasmasphere and ring current, alongside in situ measurements. Such a mission is going to be crucial on the way to achieve scientific closure on the question of solar-terrestrial interactions.

physics.space-ph

Towards 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors

We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associated with arrays of individual TESs. Hydras are under development for the next generation of space telescope such as Lynx. Lynx is a NASA concept under study that will combine a < 1 arcsecond angular resolution optic with 100,000-pixel microcalorimeter array with energy resolution of deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and 50 micron pitch are studied. Arrays incorporate, for the first time, microstrip buried wiring layers of suitable pitch and density required to readout a full-scale Lynx array. The resolution from the coadded energy histogram including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at an energy of 1.5 keV for the 25 micron and 50 micron absorber designs respectively. Position discrimination is demonstrated from parameterization of the rise-time.

astro-ph.IM

High-resolution Charge Exchange Spectra with L-shell Nickel Show Striking Differences from Models

We present the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H2 and He. We employ the commonly used charge exchange models found in XSPEC and SPEX, ACX and SPEX-CX, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. In particular, we find that configuration mixing may play an important role in generating lines from core-excited states, and may be improperly treated in models. Our results indicate that if applied to astrophysical data, these models may lead to incorrect assumptions of the physical and chemical parameters of the region of interest.

astro-ph.HE

Constraints on the Chemical Enrichment History of the Perseus Cluster of Galaxies from High-Resolution X-ray Spectroscopy

High-resolution spectroscopy of the core of the Perseus Cluster of galaxies, using the $Hitomi$ satellite above 2 keV and the $XMM$-$Newton$ Reflection Grating Spectrometer at lower energies, provides reliable constraints on the abundances of O, Ne, Mg, Si, S, Ar, Ca, Cr, Mn, Fe, and Ni. Accounting for all known systematic uncertainties, the Ar/Fe, Ca/Fe, and Ni/Fe ratios are determined with a remarkable precision of less than 10%, while the constraints on Si/Fe, S/Fe, and Cr/Fe are at the 15% level, and Mn/Fe is measured with a 20% uncertainty. The average biases in determining the chemical composition using archival CCD spectra from $XMM$-$Newton$ and $Suzaku$ range typically from 15-40%. A simple model in which the enrichment pattern in the Perseus Cluster core and the proto-solar nebula are identical gives a surprisingly good description of the high-resolution X-ray spectroscopy results, with $χ^2=10.7$ for 10 d.o.f. However, this pattern is challenging to reproduce with linear combinations of existing supernova nucleosynthesis calculations, particularly given the precise measurements of intermediate $α$-elements enabled by $Hitomi$. We discuss in detail the degeneracies between various supernova progenitor models and explosion mechanisms, and the remaining uncertainties in these theoretical models. We suggest that including neutrino physics in the core-collapse supernova yield calculations may improve the agreement with the observed pattern of $α$-elements in the Perseus Cluster core. Our results provide a complementary benchmark for testing future nucleosynthesis calculations required to understand the origin of chemical elements.

astro-ph.HE